应用超极化129Xe气体交换磁共振成像量化患者区域性放射性肺损伤
十例接受常规放射治疗的肺癌患者于放疗前和放疗后3个月接受超极化129Xe气体交换磁共振成像,其中四例在放疗后8个月复查。结果显示通气随区域剂量下降、膜摄取随剂量增加、红细胞转移随剂量下降,膜摄取在8个月时仍与剂量强相关;全肺膜摄取增加与肺功能指标下降的相关性未达统计学显著。
要点
- 放疗后3个月通气平均下降-0.24±0.05%/Gy(ρ=-0.88;P<.001)。
- 放疗后3个月膜摄取平均增加0.69±0.14%/Gy(ρ=0.94;P<.001)。
- 放疗后3个月红细胞转移平均下降-0.41±0.06%/Gy(ρ=-0.92;P<.001)。
核心结论
- 超极化129Xe磁共振成像可测量并量化区域性、放疗相关、剂量依赖的肺气体交换变化。
- 该工具可能为未来改善放射性肺损伤的理解和管理提供支持。
研究设计与样本
- 十例接受常规放射治疗的肺癌患者于放疗前和放疗后3个月接受超极化129Xe气体交换磁共振成像以绘制肺功能。
- 四例患者额外接受放疗后8个月磁共振成像复查。
- 采集胸部1H磁共振扫描,并使用形变配准将129Xe功能图转移至放射治疗计划CT扫描。
主要发现
- 与放疗前基线相比,放疗后3个月通气平均下降-0.24±0.05%/Gy(ρ=-0.88;P<.001)。
- 与放疗前基线相比,放疗后3个月膜摄取平均增加0.69±0.14%/Gy(ρ=0.94;P<.001)。
- 与放疗前基线相比,放疗后3个月红细胞转移平均下降-0.41±0.06%/Gy(ρ=-0.92;P<.001)。
- 放疗后8个月膜摄取与区域剂量保持强正相关,增加0.73±0.11%/Gy(ρ=0.92;P=.006)。
- 全肺膜摄取增加与用力肺活量下降呈中度相关(ρ=-0.50;P=.17),与一氧化碳弥散量下降呈中度相关(ρ=-0.44;P=.23),两者均未达统计学显著。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Radiation-induced lung injury has been shown to alter regional ventilation and perfusion in the lung. However, changes in regional pulmonary gas exchange have not previously been measured. METHODS AND MATERIALS: Ten patients receiving conventional radiation therapy (RT) for lung cancer underwent pre-RT and 3-month post-RT magnetic resonance imaging (MRI) using an established hyperpolarized 129Xe gas exchange technique to map lung function. Four patients underwent an additional 8-month post-RT MRI. The MR signal from inhaled xenon was measured in the following 3 pulmonary compartments: the lung airspaces, the alveolar membrane tissue, and the pulmonary capillaries (interacting with red blood cells [RBCs]). Thoracic 1H MRI scans were acquired, and deformable registration was used to transfer 129Xe functional maps to the RT planning computed tomography scan. The RT-associated changes in ventilation, membrane uptake, and RBC transfer were computed as a function of regional lung dose (equivalent dose in 2-Gy fractions). Pearson correlations and t tests were used to determine statistical significance, and weighted sum of squares linear regression subsequently characterized the dose dependence of each functional component. The pulmonary function testing metrics of forced vital capacity and diffusing capacity for carbon monoxide were also acquired at each time point. RESULTS: Compared with pre-RT baseline, 3-month post-RT ventilation decreased by an average of -0.24 ± 0.05%/Gy (ρ = -0.88; P < .001), membrane uptake increased by 0.69 ± 0.14%/Gy (ρ = 0.94; P < .001), and RBC transfer decreased by -0.41 ± 0.06%/Gy (ρ = -0.92; P < .001). Membrane uptake maintained a strong positive correlation with regional dose at 8 months post-RT, demonstrating an increase of 0.73 ± 0.11%/Gy (ρ = 0.92; P = .006). Changes in membrane uptake and RBC transfer appeared greater in magnitude (%/Gy) for individuals with low heterogeneity in their baseline lung function. An increase in whole-lung membrane uptake showed moderate correlation with decreases in forced vital capacity (ρ = -0.50; P = .17) and diffusing capacity for carbon monoxide (ρ = -0.44; P = .23), with neither correlation reaching statistical significance. CONCLUSIONS: Hyperpolarized 129Xe MRI measured and quantified regional, RT-associated, dose-dependent changes in pulmonary gas exchange. This tool could enable future work to improve our understanding and management of radiation-induced lung injury.
引用
- Rankine LJ, Lu J, Wang Z, et al. Quantifying Regional Radiation-Induced Lung Injury in Patients Using Hyperpolarized 129Xe Gas Exchange Magnetic Resonance Imaging. Int J Radiat Oncol Biol Phys. 2024. PMID: 38452858. doi:10.1016/j.ijrobp.2024.02.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。