文献速递头颈部肿瘤放疗放疗物理与技术

通道注意力增强与结构相似性约束的循环生成对抗网络用于头颈部MRI图像有效合成CT生成

Channel-wise attention enhanced and structural similarity constrained cycleGAN for effective synthetic CT generation from head and neck MRI images.
PubMed 文献 · Radiat Oncol · 2024-03-14

本研究开发并评估了一种新型无监督网络cycleSimulationGAN,用于非配对MRI到CT的合成,该网络整合了轮廓一致性损失函数和通道注意力机制。研究纳入160例接受容积旋转调强放疗的鼻咽癌患者,在20例患者上计算的平均MAE、RMSE、PSNR和SSIM分别为61.88±1.42、116.85±3.42、36.23±0.52和0.985±0.002。与传统cycleGAN相比,该方法显著改善了四项图像质量评估指标,但骨部SSIM除外。

要点

  • cycleSimulationGAN整合轮廓一致性损失和通道注意力机制,用于非配对MR到CT合成。
  • 在20例患者上平均MAE为61.88±1.42,RMSE为116.85±3.42,PSNR为36.23±0.52,SSIM为0.985±0.002。
  • 与传统cycleGAN相比,四项指标显著改善,但骨部SSIM除外。

核心结论

  • 开发的新型cycleSimulationGAN模型能有效生成合成CT图像,使其与真实CT图像相当,可能有益于基于MRI的治疗计划。

研究设计与样本

  • 研究纳入160例接受容积旋转调强放疗的鼻咽癌患者,开发并评估无监督网络cycleSimulationGAN用于非配对MR到CT合成。

主要发现

  • 在20例患者上计算的平均MAE为61.88±1.42,RMSE为116.85±3.42,PSNR为36.23±0.52,SSIM为0.985±0.002。
  • 与传统cycleGAN相比,所提方法显著改善了四项图像质量评估指标,但骨部SSIM除外。
  • 视觉检查显示,所提方法生成的合成CT与真实CT更一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Magnetic resonance imaging (MRI) plays an increasingly important role in radiotherapy, enhancing the accuracy of target and organs at risk delineation, but the absence of electron density information limits its further clinical application. Therefore, the aim of this study is to develop and evaluate a novel unsupervised network (cycleSimulationGAN) for unpaired MR-to-CT synthesis. METHODS: The proposed cycleSimulationGAN in this work integrates contour consistency loss function and channel-wise attention mechanism to synthesize high-quality CT-like images. Specially, the proposed cycleSimulationGAN constrains the structural similarity between the synthetic and input images for better structural retention characteristics. Additionally, we propose to equip a novel channel-wise attention mechanism based on the traditional generator of GAN to enhance the feature representation capability of deep network and extract more effective features. The mean absolute error (MAE) of Hounsfield Units (HU), peak signal-to-noise ratio (PSNR), root-mean-square error (RMSE) and structural similarity index (SSIM) were calculated between synthetic CT (sCT) and ground truth (GT) CT images to quantify the overall sCT performance. RESULTS: One hundred and sixty nasopharyngeal carcinoma (NPC) patients who underwent volumetric-modulated arc radiotherapy (VMAT) were enrolled in this study. The generated sCT of our method were more consistent with the GT compared with other methods in terms of visual inspection. The average MAE, RMSE, PSNR, and SSIM calculated over twenty patients were 61.88 ± 1.42, 116.85 ± 3.42, 36.23 ± 0.52 and 0.985 ± 0.002 for the proposed method. The four image quality assessment metrics were significantly improved by our approach compared to conventional cycleGAN, the proposed cycleSimulationGAN produces significantly better synthetic results except for SSIM in bone. CONCLUSIONS: We developed a novel cycleSimulationGAN model that can effectively create sCT images, making them comparable to GT images, which could potentially benefit the MRI-based treatment planning.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Gong C, Huang Y, Luo M, et al. Channel-wise attention enhanced and structural similarity constrained cycleGAN for effective synthetic CT generation from head and neck MRI images. Radiat Oncol. 2024. PMID: 38486193. doi:10.1186/s13014-024-02429-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。