头颈部肿瘤患者放疗后颈动脉纵向变化:前瞻性系列影像生物标志物特征研究结果
该前瞻性研究纳入38例接受单侧颈部放疗的头颈部肿瘤患者,系列颈动脉超声显示受照与未受照颈动脉的内中膜厚度差异在18个月出现(0.073 mm vs -0.003 mm,P=0.014),3年和4年增大;6个月整体周向应变出现短暂显著变化(中位差值-0.89,P=0.023)但未持续;其他弹性、僵硬度及扩张性指标无显著差异。作者认为这些变化可能有助于早期发现放射性颈动脉损伤,应被考虑用于放疗后生存者临床监测建议。
要点
- 受照与未受照颈动脉内中膜厚度差异在18个月出现(0.073 mm vs -0.003 mm,P=0.014),3年、4年增大。
- 6个月整体周向应变出现短暂显著变化(中位差值-0.89,P=0.023),未持续。
- 其他弹性、僵硬度及扩张性指标在受照与未受照动脉间无显著差异。
核心结论
- 颈动脉超声检测的功能与形态变化(6个月整体周向应变、18个月颈动脉内中膜厚度)可能有助于早期发现放射性颈动脉损伤。
- 这些变化可指导未来旨在减轻颈动脉狭窄的研究,应被考虑用于头颈部放疗后生存者的临床监测建议。
研究设计与样本
- 前瞻性研究,纳入38例接受单侧颈部放疗的头颈部肿瘤患者。
- 放疗后0、3、6、12、18个月及2、3、4、5年行双侧颈动脉超声检查。
- 计算内中膜厚度、整体与区域周向及径向应变、动脉弹性、僵硬度及扩张性。
主要发现
- 受照与未受照颈动脉内中膜厚度较基线的差异在18个月显著(中位0.073 mm vs -0.003 mm,P=0.014)。
- 该差异在3年增大(0.128 mm vs 0.013 mm,P=0.016),4年进一步增大(0.177 mm vs 0.023 mm,P=0.0002)。
- 受照与未受照动脉整体周向应变在6个月出现显著短暂变化(中位差值-0.89,P=0.023),未持续。
- 其他弹性、僵硬度及扩张性指标在受照与未受照动脉间未检测到显著差异。
临床怎么用
- 作者认为颈动脉超声检测的上述变化可考虑用于头颈部放疗后生存者的临床监测建议。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: We prospectively evaluated morphologic and functional changes in the carotid arteries of patients treated with unilateral neck radiation therapy (RT) for head and neck cancer. METHODS: Bilateral carotid artery duplex studies were performed at 0, 3, 6, 12, 18 months and 2, 3, 4, and 5 years following RT. Intima media thickness (IMT); global and regional circumferential, as well as radial strain, arterial elasticity, stiffness, and distensibility were calculated. RESULTS: Thirty-eight patients were included. A significant difference in the IMT from baseline between irradiated and unirradiated carotid arteries was detected at 18 months (median, 0.073 mm vs -0.003 mm; P = 0.014), which increased at 3 and 4 years (0.128 mm vs 0.013 mm, P = 0.016, and 0.177 mm vs 0.023 mm, P = 0.0002, respectively). A significant transient change was noted in global circumferential strain between the irradiated and unirradiated arteries at 6 months (median difference, -0.89, P = 0.023), which did not persist. No significant differences were detected in the other measures of elasticity, stiffness, and distensibility. CONCLUSIONS: Functional and morphologic changes of the carotid arteries detected by carotid ultrasound, such as changes in global circumferential strain at 6 months and carotid IMT at 18 months, may be useful for the early detection of radiation-induced carotid artery injury, can guide future research aiming to mitigate carotid artery stenosis, and should be considered for clinical surveillance survivorship recommendations after head and neck RT.
引用
- Koutroumpakis E, Mohamed ASR, Chaftari P, et al. Longitudinal changes in the carotid arteries of head and neck cancer patients following radiation therapy: Results from a prospective serial imaging biomarker characterization study. Radiother Oncol. 2024. PMID: 38467343. doi:10.1016/j.radonc.2024.110220
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。