文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

前列腺癌大分割放疗中野中野技术与调强放射治疗的剂量学比较

A Comparison of Field-in-Field and Intensity Modulated Radiation Therapy in Delivering Hypofractionated Radiation Therapy for Prostate Cancer.
PubMed 文献 · Adv Radiat Oncol · 2023-08-15

本研究对15例接受大分割放疗的前列腺癌患者,比较6野野中野(FIF)与9野调强放射治疗(IMRT)的剂量学表现,处方剂量为60 Gy分20次。结果显示两种技术在靶区覆盖和危及器官保护上各有优劣,FIF与IMRT在大分割放疗中结果相当。

要点

  • FIF在靶区最大剂量、2%体积剂量和均匀性指数上更优,IMRT在平均剂量、98%体积剂量和D95上更优。
  • FIF在直肠和膀胱接受60 Gy的体积上更优,IMRT在直肠和股骨头接受30 Gy的体积及直肠平均剂量上更优。
  • IMRT中位机器跳数和子野数(886 MU,64个子野)高于FIF(434 MU,6个子野)。

核心结论

  • FIF技术与IMRT在前列腺癌大分割放疗中结果相当,研究结果可能有助于患者治疗决策。

研究设计与样本

  • 本研究纳入15例接受步进式调强放射治疗的前列腺癌患者,处方剂量为60 Gy分20次。
  • FIF计划采用6个光子束,IMRT计划采用9野步进式技术。
  • 通过剂量体积直方图和剂量分布评估比较FIF与IMRT。

主要发现

  • 靶区分析显示最大剂量、2%体积剂量和均匀性指数在FIF更优,平均剂量、98%体积剂量和D95在IMRT更优,差异均有统计学意义。
  • 危及器官分析显示直肠和膀胱接受60 Gy的体积在FIF更优,直肠和股骨头接受30 Gy的体积及直肠平均剂量在IMRT更优,差异均有统计学意义。
  • IMRT的中位机器跳数和子野数(886 MU,64个子野)高于FIF(434 MU,6个子野)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study compares the dosimetric performance of the field-in-field (FIF) technique with intensity modulated radiation therapy (IMRT) for delivering hypofractionated radiation therapy to prostate patients with cancer. The FIF technique uses 6 beams, whereas IMRT uses 9 beams. METHODS AND MATERIALS: This study was conducted on 15 patients with prostate cancer treated with step-and-shoot IMRT. The prescribed dose was 60 Gy in 20 fractions. The FIF plans contained 6 photon beams, and IMRT plans were designed using a 9-field step-and-shoot technique. Dose-volume histograms and dose distributions were evaluated to compare FIF and IMRT. RESULTS: The results of the planning target volume indices analysis showed a significant difference in the maximum dose, dose to 2% of volume, and homogeneity index in favor of FIF and in the mean dose, dose to 98% of volume, and D95 in favor of IMRT. The results of the organs-at-risk analysis showed significant differences in the volume of the rectum and bladder receiving 60 Gy in favor of FIF and the volume of the rectum and femoral heads receiving 30 Gy, as well as the mean dose to the rectum, in favor of IMRT. IMRT had a higher median number of monitor units (MUs) and segments (886 MU, 64 segments) compared to FIF (434 MUs, 6 segments). CONCLUSIONS: The FIF technique and IMRT had comparable results in delivering hypofractionated radiation therapy for prostate cancer. The findings of this study may aid in decision-making for patients undergoing treatment.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Ghafour H, Ali JS, Taher Ali R, et al. A Comparison of Field-in-Field and Intensity Modulated Radiation Therapy in Delivering Hypofractionated Radiation Therapy for Prostate Cancer. Adv Radiat Oncol. 2023. PMID: 38405309. doi:10.1016/j.adro.2023.101356

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。