深吸气屏气(DIBH)用于右侧乳腺照射:改善肝脏与肺组织的保护
该回顾性研究纳入16例右侧局限性乳腺癌放疗患者,比较自由呼吸(FB)与深吸气屏气(DIBH)计划CT的剂量学差异。结果显示DIBH在保持PTV覆盖差异小于2%的同时,显著降低肝脏最大剂量及低剂量受照体积,并降低肺相对电子密度与V20Gy相对体积,但右肺V20Gy绝对体积在DIBH下更大。
要点
- DIBH与FB的PTV覆盖差异小于2%。
- DIBH下肝脏最大剂量17.5 Gy,显著低于FB的40.3 Gy(p < 0.001)。
- DIBH下肺相对电子密度0.59,显著低于FB的0.62(p < 0.001)。
核心结论
- 右侧乳腺放疗使用DIBH可显著保护肝脏与肺组织,因而具有成为右侧乳腺癌最佳实践方案的潜力。
研究设计与样本
- 回顾性纳入16例接受放疗的右侧局限性乳腺癌患者,每例患者在索引板上双臂上举固定,分别采集自由呼吸(FB)与深吸气屏气(DIBH)计划CT,两次扫描长度相同,分别在两组CT上以临床靶区(CTV)外放5 mm生成计划靶区(PTV),肝脏按扫描范围勾画。
主要发现
- FB与DIBH计划的PTV覆盖差异小于2%。
- 肝脏最大剂量DIBH为17.5 Gy,FB为40.3 Gy(p < 0.001)。
- 肝脏接受10%剂量的体积DIBH为1.88 cm3,FB为72.2 cm3(p < 0.001)。
- 右肺接受20 Gy的绝对体积DIBH为291 cm3,FB为230 cm3(p < 0.001);右肺接受大于20 Gy剂量的相对体积DIBH为11.5%,FB为14%(p = 0.007)。
- 肺相对电子密度DIBH为0.59,FB为0.62(p < 0.001),提示DIBH下肺密度较低使肺受照剂量减少。
关键数值与推荐
- 评估的剂量指标包括PTV覆盖差异、肝脏剂量(最大、平均、V90%、V50%、V30%)、肺剂量(平均、V20Gy、相对电子密度)及心脏Dmax。
- p值采用Wilcoxon符号秩检验计算,p < 0.05为显著。
临床怎么用
- 原文结论认为右侧乳腺放疗使用DIBH可显著保护肝脏与肺组织,因而具有成为右侧乳腺癌最佳实践方案的潜力。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To reduce liver and lung dose during right breast irradiation while maintaining optimal dose to the target volume. This dose reduction has the potential to decrease acute side effects and long-term toxicity. MATERIALS AND METHODS: 16 patients treated with radiation therapy for localized carcinoma of the right breast were included retrospectively. For the planning CT, each patient was immobilised on an indexed board with the arms placed above the head. CT scans were acquired in free-breathing (FB) as well as with deep inspiration breath hold (DIBH). Both scans were acquired with the same length. Planning target volumes (PTV's) were created with a 5 mm margin from the respective clinical target volumes (CTV's) on both CT datasets. The liver was outlined as scanned. Dose metrics evaluated were as follows: differences in PTV coverage, dose to the liver (max, mean, V90%, V50%, V30%), dose to lung (mean, V20Gy, relative electron density) and dose to heart (Dmax). The p-values were calculated using Wilcoxon signed-rank tests. A p-value was significant when <0.05. RESULTS: Differences in PTV coverage between plans using FB and DIBH were less than 2 %. Maximum liver dose was significantly less using DIBH: 17.5 Gy versus FB: 40.3 Gy (p < 0.001). The volume of the liver receiving 10 % of the dose was significantly less using DIBH with 1.88 cm3 versus 72.2 cm3 under FB (p < 0.001). The absolute volume receiving 20 Gy in the right lung was larger using DIBH: 291 cm3 versus 230 cm3 under FB (p < 0.001) and the relative volume of lung receiving dose greater than 20 Gy was smaller with DIBH: 11.5 % versus 14 % in FB (p = 0.007). The relative electron density of lung was significantly less with DIBH: 0.59 versus 0.62 with FB, (p < 0.001). This suggests that the lung receives less dose due to its lower density when using DIBH. CONCLUSION: Radiation of the right breast using DIBH spares liver and lung tissue significantly and thus carries the potential of best practice for right sided breast cancer.
引用
- Mader T, Pace R, Boucas da Silva RT, et al. Deep inspirational breast hold (DIBH) for right breast irradiation: Improved sparing of liver and lung tissue. Clin Transl Radiat Oncol. 2024. PMID: 38304241. doi:10.1016/j.ctro.2024.100731
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。