基于深度学习自动检测细胞核与DNA损伤灶的个体头颈癌患者离体放射敏感性评估
该研究利用21例口腔肿瘤组织离体照射(5或0 Gy)后固定,开发基于深度学习与常规图像分析技术的自动细胞核及53BP1灶分割方法。自动分割高度准确(细胞核Dice=0.901,灶Dice=0.749),每核灶数相关性优异(R2=0.802),分析每张图像约需8秒。该模型可替代离体照射头颈鳞癌组织的手动灶分析,将图像分析时间从数小时缩短至数分钟,避免观察者间变异,实现可靠快速的离体放射敏感性评估。
要点
- 自动细胞核与53BP1灶分割高度准确,Dice分别为0.901和0.749。
- 每核灶数自动与真实值相关性优异(R2=0.802),优于报道的观察者间变异。
- 分析每张图像约8秒,可替代手动分析,避免观察者间变异。
核心结论
- 该模型可替代离体照射头颈鳞癌组织的手动灶分析,将图像分析时间从数小时缩短至数分钟,避免观察者间变异,并允许评估多张图像或条件及提供灶大小信息,从而实现可靠快速的离体放射敏感性评估,作为体内反应与治疗个体化的潜在生物标志物。
研究设计与样本
- 研究对21例患者的口腔肿瘤组织进行离体照射(5或0 Gy),照射后2小时固定,用于开发自动细胞核与53BP1灶分割方法。
- 分割模型结合深度学习与常规图像分析技术,训练集(22%)、验证集(22%)和测试集(56%)包含数千个手动分割的细胞核与灶。
主要发现
- 自动细胞核与灶分割高度准确,Dice分别为0.901和0.749。
- 测试集中每核灶数的自动分析与真实值相关性优异(R2=0.802),优于报道的观察者间变异。
- 分析每张图像约需8秒。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Tumor biopsy tissue response to ex vivo irradiation is potentially an interesting biomarker for in vivo tumor response, therefore, for treatment personalization. Tumor response ex vivo can be characterized by DNA damage response, expressed by the large-scale presence of DNA damage foci in tumor nuclei. Currently, characterizing tumor nuclei and DNA damage foci is a manual process that takes hours per patient and is subjective to inter-observer variability, which is not feasible in for clinical decision making. Therefore, our goal was to develop a method to automatically segment nuclei and DNA damage foci in tumor tissue samples treated with radiation ex vivo to characterize the DNA damage response, as potential biomarker for in vivo radio-sensitivity. METHODS: Oral cavity tumor tissue of 21 patients was irradiated ex vivo (5 or 0 Gy), fixated 2 h post-radiation, and used to develop our method for automated nuclei and 53BP1 foci segmentation. The segmentation model used both deep learning and conventional image-analysis techniques. The training (22 %), validation (22 %), and test set (56 %) consisted of thousands of manually segmented nuclei and foci. The segmentations and number of foci per nucleus in the test set were compared to their ground truths. RESULTS: The automatic nuclei and foci segmentations were highly accurate (Dice = 0.901 and Dice = 0.749, respectively). An excellent correlation (R2 = 0.802) was observed for the foci per nucleus that outperformed reported inter-observation variation. The analysis took ∼ 8 s per image. CONCLUSION: This model can replace manual foci analysis for ex vivo irradiation of head-and-neck squamous cell carcinoma tissue, reduces the image-analysis time from hours to minutes, avoids the problem of inter-observer variability, enables assessment of multiple images or conditions, and provides additional information about the foci size. Thereby, it allows for reliable and rapid ex vivo radio-sensitivity assessment, as potential biomarker for response in vivo and treatment personalization.
引用
- Lauwers I, Pachler KS, Capala ME, et al. Ex vivo radiation sensitivity assessment for individual head and neck cancer patients using deep learning-based automated nuclei and DNA damage foci detection. Clin Transl Radiat Oncol. 2024. PMID: 38380115. doi:10.1016/j.ctro.2024.100735