文献速递泌尿生殖与妇科肿瘤放疗姑息放疗与转移瘤

寡复发淋巴结性前列腺癌的选择性淋巴结照射:PEACE V-STORM 随机2期试验中的观察者间变异

Elective Nodal Irradiation for Oligorecurrent Nodal Prostate Cancer: Interobserver Variability in the PEACE V-STORM Randomized Phase 2 Trial.
PubMed 文献 · Adv Radiat Oncol · 2023-06-13

本研究在PEACE V-STORM随机2期试验中,要求23家中心对一例术后寡复发淋巴结性前列腺癌基准病例,按改良RTOG 2009模板(上界L4/L5间隙)勾画 elective 盆腔淋巴结CTV,评估观察者间变异。23个CTV平均体积430.4±64.1 cm³,大于改良RTOG 2009参考体积386.1 cm³;与参考模板交集体积83.9%,溢出体积23.4%,主要位于骶前和L4/L5间隙上界;平均Dice系数0.79±0.02,平均Hausdorff距离27±4.4 mm。结论认为勾画变异主要见于骶前和髂总区域。

要点

  • 23个中心勾画的 elective 盆腔淋巴结CTV平均体积430.4±64.1 cm³,大于改良RTOG 2009参考体积386.1 cm³。
  • 与改良RTOG 2009参考模板交集体积83.9%,溢出体积23.4%,主要位于骶前和L4/L5间隙上界。
  • 平均Dice系数0.79±0.02,平均Hausdorff距离27±4.4 mm,变异主要见于骶前和髂总区域。

核心结论

  • 在寡复发淋巴结性前列腺癌挽救性放疗中, elective 淋巴结体积勾画变异主要见于骶前和髂总区域。

研究设计与样本

  • PEACE V-STORM随机2期试验中的观察者间变异评估,要求23家中心对一例术后寡复发淋巴结性前列腺癌基准病例进行勾画。
  • 勾画采用改良RTOG 2009模板,上界为L4/L5间隙。

主要发现

  • 23个淋巴结CTV平均体积430.4±64.1 cm³,大于改良RTOG 2009 CTV参考体积386.1 cm³。
  • 改良RTOG 2009参考与23个CTV的交集共同体积估计为83.9%,溢出体积为23.4%,主要位于骶前和L4/L5间隙上界水平。
  • 平均Dice系数为0.79±0.02,平均Hausdorff距离为27±4.4 mm。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Consistency in delineation of pelvic lymph node regions for prostate cancer elective nodal radiation therapy is still challenging despite current guidelines. The aim of this study was to evaluate the interobserver variability in elective lymph node delineation in the PEACE V - STORM randomized phase 2 trial for oligorecurrent nodal prostate cancer. METHODS AND MATERIALS: Twenty-three centers were asked to delineate the elective pelvic nodal clinical target volume (CTV) of a postoperative oligorecurrent nodal prostate cancer benchmark case using a modified Radiation Therapy Oncology Group (RTOG) 2009 template (upper limit at the L4/L5 interspace). Overall, intersection and overflow volumes, Dice coefficient, Hausdorff distance, and count maps merged with computed tomography images were analyzed. RESULTS: The mean volume including the 23 nodal CTVs was 430.4 ± 64.1 cm3, larger than the modified RTOG 2009 CTV reference volume (386.1 cm3). The intersection common volume between the modified reference RTOG 2009 and the 23 nodal CTVs was estimated at 83.9%, whereas the overflow volume was 23.4%, mainly located at the level of the presacral and the upper limit of the L4/L5 interspace. The mean Dice coefficient was 0.79 ± 0.02, whereas the mean Hausdorff distance was 27 ± 4.4 mm. CONCLUSIONS: In salvage radiation therapy treatment of oligorecurrent nodal prostate cancer, variations in elective lymph node volume delineation were mainly observed in the presacral and common iliac areas. Routine implementation and diffusion of available contouring guidelines together with a constant evaluation and evidence-based updating are expected to further decrease the existing variability in pelvic node contouring.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Lorton O, Achard V, Koutsouvelis N, et al. Elective Nodal Irradiation for Oligorecurrent Nodal Prostate Cancer: Interobserver Variability in the PEACE V-STORM Randomized Phase 2 Trial. Adv Radiat Oncol. 2023. PMID: 38047214. doi:10.1016/j.adro.2023.101290

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。