文献速递头颈部肿瘤放疗放疗物理与技术

头颈部肿瘤在1.5 T磁共振直线加速器上扩散加权磁共振成像的可重复性及其与3 T诊断扫描仪平行测量的比较

Reproducibility of diffusion-weighted magnetic resonance imaging in head and neck cancer assessed on a 1.5 T MR-Linac and comparison to parallel measurements on a 3 T diagnostic scanner.
PubMed 文献 · Radiother Oncol · 2023-12-07

本研究在15例头颈部肿瘤患者中,于放疗前及第2周分别在1.5 T磁共振直线加速器(MRL)和3 T诊断扫描仪(DS)上采集扩散加权磁共振图像,比较表观扩散系数(ADC)值的可重复性。共分析23个数据集,结果显示MRL测量的ADC值较DS存在低估,但可重复性合理;作者认为该ADC偏移需在进一步实验中验证,并应考虑用于将定量影像生物标志物从DS转化至MRL以实施反应适应性放疗。

要点

  • 在1.5 T MRL与3 T DS上测量的ADC值可重复性合理,但MRL测量的ADC值较DS存在低估。
  • 下颌下腺、腮腺和靶体积的组内变异系数分别为13.7%、24.4%和16.1%。
  • 作者认为该ADC偏移需在进一步实验中验证,并应考虑用于将定量影像生物标志物从DS转化至MRL。

核心结论

  • 在1.5 T MRL上测量的ADC值显示出合理的可重复性,但与DS相比存在ADC低估。
  • 该ADC偏移必须在进一步实验中验证,并应考虑用于未来将定量影像生物标志物候选者从DS转化至MRL以实施反应适应性放疗。

研究设计与样本

  • 对15例头颈部肿瘤患者在放疗前及第2周分别在1.5 T MRL和3 T DS上采集扩散加权磁共振图像,并刚性配准至计划CT。
  • 基于CT勾画下颌下腺、腮腺及靶体积(大体肿瘤体积和淋巴结),计算各感兴趣区的平均ADC值、平均绝对ADC差异、组内变异系数(wCV)和组内相关系数(ICC)。
  • 共分析23个数据集。

主要发现

  • 下颌下腺、腮腺和靶体积的平均ADC差异(DS-MRL)分别为142、254和93×10^-6 mm²/s。
  • 比较MRL与DS的下颌下腺wCV/ICC为13.7%/0.26。
  • 比较MRL与DS的腮腺wCV/ICC为24.4%/0.23。
  • 比较MRL与DS的靶体积wCV/ICC为16.1%/0.73。

局限性

  • 作者指出该ADC偏移必须在进一步实验中验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Before quantitative imaging biomarkers (QIBs) acquired with magnetic resonance imaging (MRI) can be used for interventional trials in radiotherapy (RT), technical validation of these QIBs is necessary. The aim of this study was to assess the reproducibility of apparent diffusion coefficient (ADC) values, derived from diffusion-weighted (DW) MRI, in head and neck cancer using a 1.5 T MR-Linac (MRL) by comparison to a 3 T diagnostic scanner (DS). MATERIAL AND METHODS: DW-MRIs were acquired on MRL and DS for 15 head and neck cancer patients before RT and in week 2 and rigidly registered to the planning computed tomography. Mean ADC values were calculated for submandibular (SG) and parotid (PG) glands as well as target volumes (TV, gross tumor volume and lymph nodes), which were delineated based on computed tomography. Mean absolute ADC differences as well as within-subject coefficient of variation (wCV) and intraclass correlation coefficients (ICCs) were calculated for all volumes of interest. RESULTS: A total of 23 datasets were analyzed. Mean ADC difference (DS-MRL) for SG, PG and TV resulted in 142, 254 and 93·10-6 mm2/s. wCVs/ICCs, comparing MRL and DS, were determined as 13.7 %/0.26, 24.4 %/0.23 and 16.1 %/0.73 for SG, PG and TV, respectively. CONCLUSION: ADC values, measured on the 1.5 T MRL, showed reasonable reproducibility with an ADC underestimation in contrast to the DS. This ADC shift must be validated in further experiments and considered for future translation of QIB candidates from DS to MRL for response adaptive RT.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Habrich J, Boeke S, Fritz V, et al. Reproducibility of diffusion-weighted magnetic resonance imaging in head and neck cancer assessed on a 1.5 T MR-Linac and comparison to parallel measurements on a 3 T diagnostic scanner. Radiother Oncol. 2023. PMID: 38070687. doi:10.1016/j.radonc.2023.110046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。