文献速递消化道肿瘤放疗放疗物理与技术姑息放疗与转移瘤

影像引导术中电子线放疗联合实时术中剂量计算在复发性直肠癌中的首次临床应用:技术流程

First clinical application of image-guided intraoperative electron radiation therapy with real time intraoperative dose calculation in recurrent rectal cancer: technical procedure.
PubMed 文献 · Radiat Oncol · 2023-11-10

本文报告首例腹盆腔影像引导术中电子线放疗(IORT)联合基于患者术中个体解剖的实时剂量计算。患者为新辅助再放化疗后局部区域复发性直肠癌,手术切除复发灶后放置IORT施源器,用移动成像设备(ImagingRing,MedPhoton)获取三维术中锥形束CT图像并经HU自动缩放校正用于剂量计算,确认施源器位置后将图像转入治疗计划系统完成术中剂量计算并据此完成治疗。文中描述了流程细节、所需设备与工作流调整,并讨论该新方法克服IORT十余年局限的利弊及未来前景。

要点

  • 首例腹盆腔影像引导IORT联合实时术中剂量计算用于复发性直肠癌。
  • 术中锥形束CT经HU自动缩放校正后用于剂量计算并确认施源器位置。
  • 文中描述流程细节、设备与工作流调整及该方法的利弊与未来前景。

核心结论

  • 本文报告首例腹盆腔影像引导术中电子线放疗联合基于术中个体解剖的实时剂量计算的临床应用,并描述其技术流程。

研究设计与样本

  • 本文为单例技术报告,患者为新辅助再放化疗后局部区域复发性直肠癌。

主要发现

  • 手术切除复发灶后按常规放置合适的IORT施源器,并将移动成像设备(ImagingRing,MedPhoton)置于患者周围覆盖治疗区域。
  • 该设备获取三维术中锥形束CT图像,经Hounsfield单位自动缩放(启发式物体与头部散射及硬化校正)后适用于剂量计算。
  • 图像采集确认施源器位置正确后,图像转入治疗计划系统进行术中剂量计算,治疗可依据计算的剂量分布完成。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Intraoperative radiation therapy (IORT) is a radiation technique applying a single fraction with a high dose during surgery. We report the first abdomino-pelvic application of an image-guided intraoperative electron radiation therapy with intraoperative real time dose calculation based on the individual intraoperative patient anatomy. A patient suffering from locoregionally recurrent rectal cancer after treatment with neoadjuvant re-chemoradiation was chosen for this approach. After surgical removal of the recurrence, an adequate IORT applicator was placed as usual. A novel mobile imaging device (ImagingRing, MedPhoton) was positioned around the patient covering the region to be treated with the IORT-applicator in place. It allowed the acquisition of three-dimensional intraoperative cone-beam computed tomography images suitable for dose calculation using an automated scaling (heuristic object and head scatter as well as hardening corrections) of Hounsfield units. After image acquisition confirmed the correct applicator position, the images were transferred to our treatment planning system for intraoperative dose calculation. Treatment could be accomplished using the calculated dose distribution. We herein describe the details of the procedure including necessary adjustments in the typically used IORT equipment and work flow. We further discuss the pros and cons of this new approach generally overcoming a decade long limitation of IORT procedures as well as future perspectives regarding IORT treatments.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Roeder F, Fastner G, Fussl C, et al. First clinical application of image-guided intraoperative electron radiation therapy with real time intraoperative dose calculation in recurrent rectal cancer: technical procedure. Radiat Oncol. 2023. PMID: 37950314. doi:10.1186/s13014-023-02374-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。