非小细胞肺癌放疗剂量-反应关系与肺灌注损失的比较:正电子发射断层扫描与双能计算机断层扫描

Dose-Response Relationship Between Radiation Therapy and Loss of Lung Perfusion Comparing Positron Emission Tomography and Dual-Energy Computed Tomography in Non-Small Cell Lung Cancer.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2023-10-31

该研究基于前瞻性临床试验HI-FIVE(NTC03569072)的预设分析,纳入19例非小细胞肺癌患者,比较68Ga-大颗粒聚合白蛋白PET/CT与增强DECT测得的肺灌注剂量-反应曲线。结果显示,在30%SUVmax/35%IoMax阈值下,PET与DECT的剂量-反应曲线在治疗后3个月和12个月具有可比性。

要点

  • 在30%SUVmax/35%IoMax阈值下,PET与DECT的剂量-反应曲线平均归一化重叠最大化。
  • 3个月时PET与DECT线性模型斜率分别为0.76%/Gy与0.75%/Gy。
  • 12个月时PET与DECT线性模型斜率分别为0.86%/Gy与0.87%/Gy。

核心结论

  • 在非小细胞肺癌患者中,治疗后3个月和12个月由DECT测得的剂量-反应关系与PET测得的剂量-反应关系具有可比性。

研究设计与样本

  • 该研究为前瞻性临床试验HI-FIVE(NTC03569072)的预设分析,纳入19例非小细胞肺癌患者。
  • 患者在基线及治疗后3个月和12个月同一天接受68Ga-大颗粒聚合白蛋白PET/CT检查和增强DECT。
  • 灌注肺基于PET/DECT的最大标准化摄取值百分比(%SUVmax)/碘浓度百分比(%IoMax)阈值定义。

主要发现

  • 19例入组患者中,分别有14例和10例在治疗后中位4.5个月和13.5个月进行了影像学随访。
  • 在30%SUVmax/35%IoMax阈值下,PET与DECT的剂量-反应曲线平均归一化重叠最大化,且各时间点两者线性模型斜率差异最小。
  • 3个月时由PET/DECT确定的线性模型斜率分别为0.76%/Gy和0.75%/Gy。
  • 12个月时由PET/DECT确定的线性模型斜率分别为0.86%/Gy和0.87%/Gy。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation therapy treatment for non-small cell lung cancer (NSCLC) may result in radiation damage to the perfused lung. The loss in perfusion may be measured from positron tomography emission (PET) perfusion imaging; however, this modality may not be widely available. Dual-energy computed tomography (DECT) with contrast may be an alternative to PET/CT. The purpose of this work is to investigate the equivalence of dose-response curves (DRCs) determined from PET and DECT in NSCLC. METHODS AND MATERIALS: PET and DECT data sets from the prospective clinical trial HI-FIVE (NTC03569072) were included in this preplanned trial analysis. Patients underwent 68Ga-macroaggregated albumin PET/CT examination and DECT with contrast on the same day at baseline and at 3 and 12 months after treatment. The perfused lung was defined from a threshold based on the maximum standardized uptake value (%SUVmax)/iodine concentration (%IoMax) in PET/DECT. The equivalence between PET and DECT DRC was established by comparing (1) the average of the normalized overlap of the 2 DRCs ranging from 0 (no overlap) to 1 (perfect overlap) and (2) the slope of a linear model applied to DRCs. RESULTS: Of the 19 patients enrolled in the clinical trial, 14/10 patients had a posttreatment imaging session at a median of 4.5/13.5 months, respectively. With 30%SUVmax/35%IoMax, the average normalized overlap was maximized, and the difference between PET and DECT slopes of the linear model was minimized at each time point (slope = 0.76%/Gy / 0.75%/Gy at 3 months and 0.86%/Gy / 0.87%/Gy at 12 months determined from PET/DECT). CONCLUSIONS: The dose-response relationship determined from DECT was comparable to that from PET at 3 and 12 months after treatment in patients with NSCLC.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Gaudreault M, Bucknell N, Woon B, et al. Dose-Response Relationship Between Radiation Therapy and Loss of Lung Perfusion Comparing Positron Emission Tomography and Dual-Energy Computed Tomography in Non-Small Cell Lung Cancer. Int J Radiat Oncol Biol Phys. 2023. PMID: 37914141. doi:10.1016/j.ijrobp.2023.10.038