文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

放射治疗期间前列腺分次内运动监测:聚焦综述提出的实践要点

Monitoring Intrafraction Motion of the Prostate During Radiation Therapy: Suggested Practice Points From a Focused Review.
PubMed 文献 · Pract Radiat Oncol · 2023-10-22

该聚焦综述围绕前列腺癌外照射放疗中分次内运动(IFM)的三个关键临床问题检索文献并给出循证推荐。IFM通常≤3 mm,在PTV外扩≥3至5 mm且治疗时间较短时对剂量学影响有限;约10%的治疗分次可见≥5 mm的IFM。当需要更紧的PTV外扩、超低分次方案或治疗时间超过数分钟时,监测与校正IFM可能最有价值。

要点

  • IFM通常≤3 mm,在PTV外扩≥3至5 mm且治疗时间较短时不太可能对前列腺剂量学造成有临床意义的影响。
  • 约10%的治疗分次中观察到≥5 mm的IFM,其剂量学影响因发生不频繁和治疗分次较长而有限。
  • 当需要更紧的PTV外扩(如SBRT或前列腺内结节推量)、超低分次方案或治疗时间超过数分钟时,校正IFM可能最有价值。

核心结论

  • 该聚焦综述总结了前列腺癌外照射放疗中IFM的文献,并提供了关于IFM管理的实践推荐。

研究设计与样本

  • 聚焦综述,对前列腺癌放疗期间前列腺运动的相关文献进行了全面检索,围绕3个关键临床问题组织信息并给出循证推荐。

主要发现

  • 放疗期间前列腺IFM通常≤3 mm,对于治疗时间较短且PTV外扩≥3至5 mm的患者,不太可能对前列腺剂量学造成有临床意义的影响。
  • 约10%的治疗分次中观察到≥5 mm的IFM,其剂量学影响因发生不频繁和治疗分次较长而有限。
  • IFM可通过多种影像平台以连续或非连续方式监测。
  • 当需要更紧的PTV外扩(如立体定向体部放疗或前列腺内结节推量)、超低分次方案或治疗时间超过数分钟时,校正IFM可能最有价值。

关键数值与推荐

  • IFM通常≤3 mm;PTV外扩≥3至5 mm且治疗时间较短时,IFM不太可能对前列腺剂量学造成有临床意义的影响。
  • 约10%的治疗分次中观察到≥5 mm的IFM。
  • 当需要更紧的PTV外扩(如SBRT或前列腺内结节推量)、超低分次方案或治疗时间超过数分钟时,校正IFM可能最有价值。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: External beam radiation therapy to the prostate is typically delivered after verification of prostatic position with image guidance. Prostate motion can occur during the delivery of each radiation treatment between the time of localization imaging and completion of treatment. The objective of this work is to review the literature on intrafraction motion (IFM) of the prostate during radiation therapy and offer clinical recommendations on management. METHODS AND MATERIALS: A comprehensive literature review was conducted on prostate motion during prostate cancer radiation therapy. Information was organized around 3 key clinical questions, followed by an evidence-based recommendation. RESULTS: IFM of the prostate during radiation therapy is typically ≤3 mm and is unlikely to compromise prostate dosimetry to a clinically meaningful degree for men treated in a relatively short treatment duration with planning target volume (PTV) margins of ≥3 to 5 mm. IFM of 5 mm or more has been observed in up to ∼10% of treatment fractions, with limited dosimetric effect related to the infrequency of occurrence and longer fractionation of therapy. IFM can be monitored in continuous or discontinuous fashion with a variety of imaging platforms. Correction of IFM may have the greatest value when tighter PTV margins are desired (such as with stereotactic body radiation therapy or intraprostatic nodule boosting), ultrahypofractionated courses, or when treatment time exceeds several minutes. CONCLUSIONS: This focused review summarizes literature and provides practical recommendations regarding IFM in the treatment of prostate cancer with external beam radiation therapy.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Shimomura A, Wu T, Rusu I, et al. Monitoring Intrafraction Motion of the Prostate During Radiation Therapy: Suggested Practice Points From a Focused Review. Pract Radiat Oncol. 2023. PMID: 37875222. doi:10.1016/j.prro.2023.08.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。