文献速递乳腺癌放疗放疗物理与技术

先验信息引导的乳腺癌术后放疗瘤床临床靶区自动分割

Prior information guided auto-segmentation of clinical target volume of tumor bed in postoperative breast cancer radiotherapy.
PubMed 文献 · Radiat Oncol · 2023-10-15

本研究将术前CT肿瘤轮廓经形变图像配准映射至术后CT,作为先验信息训练深度学习模型,用于乳腺癌术后放疗瘤床临床靶区(CTV-TB)自动分割。使用110对术前术后CT图像行5折交叉验证,结果显示含先验信息模型的平均DSC为0.808,优于无先验信息模型的0.734及传统方法的0.622(均P < 0.05)。

要点

  • 术前CT肿瘤轮廓经形变配准映射至术后CT可作为先验信息。
  • 含先验信息深度学习模型平均DSC为0.808,高于无先验信息的0.734(P < 0.05)。
  • 含先验信息模型平均DSC为0.808,高于传统方法的0.622(P < 0.05)。

核心结论

  • 在深度学习模型中引入先验信息可提高瘤床临床靶区(CTV-TB)的分割精度。
  • 所提方法为乳腺癌术后放疗中自动勾画CTV-TB提供了有效途径。

研究设计与样本

  • 研究将术前CT上的肿瘤轮廓通过形变图像配准变换至术后CT,原始与变换后的肿瘤轮廓均作为先验信息用于训练自动分割模型。
  • 模型随后在术后CT上预测CTV-TB轮廓,预测轮廓与临床批准的轮廓进行比较,采用戴斯相似系数(DSC)和豪斯多夫距离评价精度。
  • 研究使用110对术前与术后CT图像,采用5折交叉验证策略。

主要发现

  • 含先验信息深度学习模型的平均DSC为0.808,高于无先验信息模型的0.734(P < 0.05)。
  • 含先验信息深度学习模型的平均DSC为0.808,高于传统方法的0.622(P < 0.05)。

临床怎么用

  • 原文结论认为,在深度学习模型中引入先验信息可提高CTV-TB分割精度,所提方法为乳腺癌术后放疗中自动勾画CTV-TB提供了有效途径。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Accurate delineation of clinical target volume of tumor bed (CTV-TB) is important but it is also challenging due to surgical effects and soft tissue contrast. Recently a few auto-segmentation methods were developed to improve the process. However, those methods had comparatively low segmentation accuracy. In this study the prior information was introduced to aid auto-segmentation of CTV-TB based on a deep-learning model. METHODS: To aid the delineation of CTV-TB, the tumor contour on preoperative CT was transformed onto postoperative CT via deformable image registration. Both original and transformed tumor contours were used for prior information in training an auto-segmentation model. Then, the CTV-TB contour on postoperative CT was predicted by the model. 110 pairs of preoperative and postoperative CT images were used with a 5-fold cross-validation strategy. The predicted contour was compared with the clinically approved contour for accuracy evaluation using dice similarity coefficient (DSC) and Hausdorff distance. RESULTS: The average DSC of the deep-learning model with prior information was improved than the one without prior information (0.808 vs. 0.734, P < 0.05). The average DSC of the deep-learning model with prior information was higher than that of the traditional method (0.808 vs. 0.622, P < 0.05). CONCLUSIONS: The introduction of prior information in deep-learning model can improve segmentation accuracy of CTV-TB. The proposed method provided an effective way to automatically delineate CTV-TB in postoperative breast cancer radiotherapy.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Xie X, Song Y, Ye F, et al. Prior information guided auto-segmentation of clinical target volume of tumor bed in postoperative breast cancer radiotherapy. Radiat Oncol. 2023. PMID: 37840132. doi:10.1186/s13014-023-02355-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。