文献速递胸部肿瘤放疗姑息放疗与转移瘤

重复深吸气屏气CT扫描在计划阶段低估肺癌与淋巴瘤患者治疗中屏气间实际运动

Repeated deep-inspiration breath-hold CT scans at planning underestimate the actual motion between breath-holds at treatment for lung cancer and lymphoma patients.
PubMed 文献 · Radiother Oncol · 2023-09-01

研究纳入29例肺癌和9例淋巴瘤患者行深吸气屏气(DIBH)放疗,比较计划CT四次DIBH扫描间与治疗前后CBCT间的靶区屏气内位移。肺癌原发灶在CBCT的最大绝对位移均值大于CT(头脚方向6.1 mm vs 3.3 mm),淋巴结和淋巴瘤靶区无差异。计划期DIBH位移整体小于治疗时,低估了分次内DIBH不确定性。

要点

  • 肺癌原发灶头脚方向最大绝对位移均值CBCT为6.1 mm,CT为3.3 mm。
  • 肺癌原发灶左右和头脚方向位移标准差CBCT大于CT。
  • 淋巴结靶区和淋巴瘤靶区的最大绝对位移均值或标准差未见差异。

核心结论

  • 计划CT阶段的屏气内位移通常小于治疗前后CBCT观察到的屏气内位移,因此低估了治疗中分次内DIBH不确定性。
  • 肺肿瘤的分次内变异大于淋巴结和淋巴瘤靶区。

研究设计与样本

  • 29例肺癌和9例淋巴瘤患者接受DIBH放疗,使用2 mm窗宽的外部呼吸门控块作为DIBH水平替代。
  • 计划期采集4次DIBH CT(1次计划CTDIBH3,另3次CTDIBH1、2、4用于评估扫描时屏气内靶区位移)。
  • 治疗中每次采集治疗前(CBCTpre)和治疗后(CBCTpost)扫描,计算每对CBCTpre/post的靶区屏气内位移。
  • 肺癌分别分析肿瘤(GTV-Tlung)和淋巴结(GTV-Nlung)。

主要发现

  • GTV-Tlung的最大绝对位移均值在CBCT所有方向均大于CT,头脚方向CT为3.3 mm、CBCT为6.1 mm。
  • GTV-Tlung左右和头脚方向位移的标准差CBCT大于CT。
  • GTV-Nlung和CTVlymphoma的最大绝对位移均值或标准差未见差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE/OBJECTIVE: Deep-inspiration breath-hold (DIBH) during radiotherapy may reduce dose to the lungs and heart compared to treatment in free breathing. However, intra-fractional target shifts between several breath-holds may decrease target coverage. We compared target shifts between four DIBHs at the planning-CT session with those measured on CBCT-scans obtained pre- and post-DIBH treatments. MATERIAL/METHODS: Twenty-nine lung cancer and nine lymphoma patients were treated in DIBH. An external gating block was used as surrogate for the DIBH-level with a window of 2 mm. Four DIBH CT-scans were acquired: one for planning (CTDIBH3) and three additional (CTDIBH1,2,4) to assess the intra-DIBH target shifts at scanning by registration to CTDIBH3. During treatment, pre-treatment (CBCTpre) and post-treatment (CBCTpost) scans were acquired. For each pair of CBCTpre/post, the target intra-DIBH shift was determined. For lung cancer, tumour (GTV-Tlung) and lymph nodes (GTV-Nlung) were analysed separately. Group mean (GM), systematic and random errors, and GM for the absolute maximum shifts (GMmax) were calculated for the shifts between CTDIBH1,2,3,4 and between CBCTpre/post. RESULTS: For GTV-Tlung, GMmax was larger at CBCT than CT in all directions. GMmax in cranio-caudal direction was 3.3 mm (CT)and 6.1 mm (CBCT). The standard deviations of the shifts in the left-right and cranio-caudal directions were larger at CBCT than CT. For GTV-Nlung and CTVlymphoma, no difference was found in GMmax or SD. CONCLUSION: Intra-DIBH shifts at planning-CT session are generally smaller than intra-DIBH shifts observed at CBCTpre/post and therefore underestimate the intra-fractional DIBH uncertainty during treatment. Lung tumours show larger intra-fractional variations than lymph nodes and lymphoma targets.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Hoffmann L, Ehmsen ML, Hansen J, et al. Repeated deep-inspiration breath-hold CT scans at planning underestimate the actual motion between breath-holds at treatment for lung cancer and lymphoma patients. Radiother Oncol. 2023. PMID: 37659663. doi:10.1016/j.radonc.2023.109887

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。