共识指南对头颈部肿瘤原发肿瘤临床靶区(CTVp)勾画的影响:一项全国性审查项目的结果
该全国性审查项目邀请比利时所有放疗科室完成在线调查并为5个参考病例提交CTVp,17个完成调查和勾画的中心中88%已实施共识指南。遵循指南的中心其IOVall和IOVref显著改善(p=0.005),CTVp_total的DSCref中位数为0.80-0.92,CTVp_high的IOVref较小且所有病例DSC高于0.90,同时观察到接受70 Gy的CTVp体积显著减小。作者认为指南实施已相当深入并显著提高勾画一致性,但高剂量CTV的明显减小需谨慎并正确解读指南,尤其对口咽癌和下咽癌似宜对现有指南进行澄清。
要点
- 17个完成调查和勾画的中心中88%已实施共识指南。
- 遵循指南的中心其IOVall和IOVref显著改善(p=0.005)。
- CTVp_total的DSCref中位数为0.80-0.92,CTVp_high所有病例DSC高于0.90。
核心结论
- 共识指南的实施在全国层面已相当深入,显著提高了勾画一致性。
- 接受高剂量放疗的CTV明显减小,需谨慎并正确解读共识指南。
- 作者认为对现有指南进行澄清似为适宜,尤其对口咽癌和下咽癌。
研究设计与样本
- 邀请比利时所有放疗科室完成在线调查并为5个参考病例提交CTVp的全国性审查项目。
- 危及器官和原发肿瘤GTV预先定义,计算边界、体积、所有参与中心间IOV(IOVall)及与参考共识勾画比较的IOV(IOVref),并与先前分析比较。
- 对每个病例进行定性分析以评估对共识指南的正确解读。
主要发现
- 17个放疗中心完成调查和勾画,其中88%已实施共识指南。
- CTVp_total的DSCref中位数为0.80-0.92。
- 遵循指南的中心其IOVall和IOVref显著改善(p=0.005)。
- CTVp_high的IOVref较小,所有病例DSC高于0.90。
- 观察到接受70 Gy的CTVp体积显著减小;对(声门上)喉癌的指南解读更准确;60%的放射肿瘤学家认为需要对指南进行澄清。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: A significant interobserver variability (IOV) for clinical target volume of the primary tumor (CTVp) delineation was shown in a previous national review project. Since then, international expert consensus guidelines (CG) for the delineation of CTVp were published. The aim of this follow-up study was to 1) objectify the extent of implementation of the CG, 2) assess its impact on delineation quality and consistency, 3) identify any remaining ambiguities. MATERIALS AND METHODS: All Belgian RT departments were invited to complete an online survey and submit CTVp for 5 reference cases. Organs at risk and GTV of the primary tumor were predefined. Margins, volumes, IOV between all participating centers (IOVall) and IOV compared to a reference consensus delineation (IOVref) were calculated and compared to the previous analysis. A qualitative analysis was performed assessing the correct interpretation of the CG for each case. RESULTS: 17 RT centers completed both survey and delineations, of which 88% had implemented CG. Median DSCref for CTVp_total was 0.80-0.92. IOVall and IOVref improved significantly for the centers following CG (p = 0.005). IOVref for CTVp_high was small with a DSC higher than 0.90 for all cases. A significant volume decrease for the CTVp receiving 70 Gy was observed. Interpretation of CG was more accurate for (supra)glottic carcinoma. 60% of the radiation oncologists thinks clarification of CG is indicated. CONCLUSION: Implementation of consensus guidelines for CTVp delineation is already fairly advanced on a national level, resulting in significantly increased delineation uniformity. The accompanying substantial decrease of CTV receiving high dose RT calls for caution and correct interpretation of CG. Clarification of the existing guidelines seems appropriate especially for oropharyngeal and hypopharyngeal carcinoma.
引用
- Bollen H, Gulyban A, Nuyts S, et al. Impact of consensus guidelines on delineation of primary tumor clinical target volume (CTVp) for head and neck cancer: Results of a national review project. Radiother Oncol. 2023. PMID: 37739317. doi:10.1016/j.radonc.2023.109915
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。