文献速递胸部肿瘤放疗放疗物理与技术

量化基于四维计算机断层扫描的可变形剂量累积对标准分割调强放疗的局部晚期非小细胞肺癌患者放射损伤表征的影响

Quantifying the Effect of 4-Dimensional Computed Tomography-Based Deformable Dose Accumulation on Representing Radiation Damage for Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Standard-Fractionated Intensity-Modulated Radiation Therapy.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2023-08-08

该研究回顾性纳入67例来自随机临床试验的局部晚期非小细胞肺癌患者,比较基于四维CT的可变形剂量累积与计划剂量在剂量学和临床效应上的差异。累积剂量较计划剂量平均肺剂量增加小于1 Gy、NTCP增加小于2%,且基于影像密度改变的模型拟合在累积剂量下更优,尤其在NTCP差异≥2%的患者中改善更明显。

要点

  • 累积剂量较计划剂量平均肺剂量增加<1 Gy、NTCP增加<2%,个别患者可达8.2 Gy和18.8%。
  • 体素水平剂量-影像密度改变模型拟合从计划剂量到累积剂量改善(伪R²增加0.0023)。
  • NTCP差异≥2%的患者较<2%的患者模型拟合改善更明显。

核心结论

  • 基于相对较大队列、稳健图像配准、多层级指标比较和影像学证据,证明剂量累积更准确地代表实际交付剂量,且对纵向反应较大的患者可能尤其有益。

研究设计与样本

  • 回顾性从一项随机临床试验中选取67例接受标准分割调强放疗的局部晚期非小细胞肺癌患者。
  • 将原始调强放疗计划、计划与验证四维CT及约4个月治疗后随访CT导入商业治疗计划系统,采用两种可变形图像配准算法进行剂量累积并评估其准确性。

主要发现

  • 与计划剂量相比,累积剂量平均导致肺剂量增加<1 Gy、NTCP增加<2%(个别患者分别可达8.2 Gy和18.8%)。
  • 计划与累积剂量分布之间的等剂量区间体积重叠范围为0.01至0.93。
  • 体素水平剂量-影像密度改变模型拟合从计划剂量到累积剂量改善(伪R²增加0.0023),且NTCP差异≥2%的患者较<2%的患者改善更明显。

关键数值与推荐

  • 比较计划剂量与累积剂量(基于平均强度图像或相位图像计算)的肺平均剂量和≥2级放射性肺炎的正常组织并发症概率(NTCP)。
  • 比较肺亚区平均剂量和等剂量区间体积重叠,并评估剂量-影像密度改变模型的拟合优度。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this study was to investigate the dosimetric and clinical effects of 4-dimensional computed tomography (4DCT)-based longitudinal dose accumulation in patients with locally advanced non-small cell lung cancer treated with standard-fractionated intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS: Sixty-seven patients were retrospectively selected from a randomized clinical trial. Their original IMRT plan, planning and verification 4DCTs, and ∼4-month posttreatment follow-up CTs were imported into a commercial treatment planning system. Two deformable image registration algorithms were implemented for dose accumulation, and their accuracies were assessed. The planned and accumulated doses computed using average-intensity images or phase images were compared. At the organ level, mean lung dose and normal-tissue complication probability (NTCP) for grade ≥2 radiation pneumonitis were compared. At the region level, mean dose in lung subsections and the volumetric overlap between isodose intervals were compared. At the voxel level, the accuracy in estimating the delivered dose was compared by evaluating the fit of a dose versus radiographic image density change (IDC) model. The dose-IDC model fit was also compared for subcohorts based on the magnitude of NTCP difference (|ΔNTCP|) between planned and accumulated doses. RESULTS: Deformable image registration accuracy was quantified, and the uncertainty was considered for the voxel-level analysis. Compared with planned doses, accumulated doses on average resulted in <1-Gy lung dose increase and <2% NTCP increase (up to 8.2 Gy and 18.8% for a patient, respectively). Volumetric overlap of isodose intervals between the planned and accumulated dose distributions ranged from 0.01 to 0.93. Voxel-level dose-IDC models demonstrated a fit improvement from planned dose to accumulated dose (pseudo-R2 increased 0.0023) and a further improvement for patients with ≥2% |ΔNTCP| versus for patients with <2% |ΔNTCP|. CONCLUSIONS: With a relatively large cohort, robust image registrations, multilevel metric comparisons, and radiographic image-based evidence, we demonstrated that dose accumulation more accurately represents the delivered dose and can be especially beneficial for patients with greater longitudinal response.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. He Y, Cazoulat G, Wu C, et al. Quantifying the Effect of 4-Dimensional Computed Tomography-Based Deformable Dose Accumulation on Representing Radiation Damage for Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Standard-Fractionated Intensity-Modulated Radiation Therapy. Int J Radiat Oncol Biol Phys. 2023. PMID: 37552151. doi:10.1016/j.ijrobp.2023.07.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。