文献速递头颈部肿瘤放疗放疗物理与技术

头颈部放疗中临床靶区残余几何误差的评估及其对剂量累积的影响

Assessment of residual geometrical errors of clinical target volumes and their impact on dose accumulation for head and neck radiotherapy.
PubMed 文献 · Radiother Oncol · 2023-08-18

本研究分析28例接受70 Gy(RBE)和54.25 Gy(RBE)质子治疗的头颈癌患者,通过每日锥形束CT生成合成CT并混合形变配准传播临床靶区,量化残余几何误差dr。结果显示CTV70的dr为1.91 mm、CTV54.25为1.90 mm,环状软骨上下方CTV54.25差异显著(1.00 mm vs 3.93 mm),累积剂量TCP高于体素最小剂量TCP。作者认为2 mm摆位不确定度设置可行。

要点

  • 28例头颈癌质子治疗患者中,CTV70的残余几何误差dr为1.91 mm,CTV54.25为1.90 mm。
  • 环状软骨上方CTV54.25的dr为1.00 mm,下方为3.93 mm,下方覆盖率几乎总是更低。
  • 传播CTV与医师校正CTV的dr差异小(CTV70为0.16 mm,CTV54.25为0.26 mm),平均DSC差异小于0.9%。

核心结论

  • 作者认为2 mm的摆位不确定度设置是可能的,并证明使用传播CTV进行误差确定具有可行性。

研究设计与样本

  • 研究纳入28例头颈癌质子治疗患者,治疗剂量为CTV70 70 Gy(RBE)、CTV54.25 54.25 Gy(RBE)。
  • 将每日锥形束CT转换为高质量合成CT,在RayStation 11B中使用混合形变图像配准将名义CT的CTV传播至对应合成CT。
  • 对11例患者的全部传播CTV由本中心头颈放疗医师审核(医师校正CTV)。
  • 残余几何误差dr量化为每日CTV与名义计划CTV体积重叠的函数,并比较传播CTV与医师校正CTV的dr及Dice相似系数差值(ΔDSC)。
  • 基于临床计划确定名义、累积和体素最小场景的剂量覆盖和肿瘤控制概率(TCP)。

主要发现

  • 传播CTV与医师校正CTV的残余几何误差差值:Δdr(CTV70)=0.16 mm,Δdr(CTV54.25)=0.26 mm,平均|ΔDSC|小于0.9%。
  • 全部28例患者中,dr(CTV70)=1.91 mm,dr(CTV54.25)=1.90 mm。
  • 环状软骨上方与下方CTV54.25的dr分别为1.00 mm与3.93 mm,差异显著。
  • 环状软骨下方CTV54.25的覆盖率几乎总是更低,但累积剂量的TCP高于体素最小剂量的TCP。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the residual geometrical errors (dr) and their impact on the clinical target volumes (CTV) dose coverage for head and neck cancer (HNC) proton therapy patients. METHODS: We analysed 28 HNC patients treated with 70 Gy (RBE) and 54.25 Gy (RBE) to the therapeutic CTV70 and prophylactic CTV54.25, respectively. Daily cone beam CTs were converted to high quality synthetic CTs (sCTs). The CTVs from the nominal CT were propagated to the corresponding sCTs using a hybrid deformable image registration (propagated CTVs) in RayStation 11B. For 11 patients, all propagated CTVs were reviewed by our HNC radiation oncologist (physician corrected CTVs). The residual geometrical error dr was quantified as a function of the daily CTVs volume overlap with the nominal plan CTV. The errors dr(propagated CTVs) and dr(physician corrected CTVs) and the difference in dice similarity coefficients (ΔDSC) were determined. Using clinical plans, dose coverage and the tumor control probability (TCP) for the nominal, accumulated and voxel-wise minimum scenarios were determined. RESULTS: The difference in the residual geometrical error dr (propagated CTVs - physician corrected CTVs) and mean DSC (|ΔDSC|mean) were minor: Δdr(CTV70) = 0.16 mm, Δdr(CTV54.25) = 0.26 mm, |ΔDSC|mean < 0.9%. For all 28 patients, dr(CTV70) = 1.91 mm and dr(CTV54.25) = 1.90 mm. However, CTV54.25 above and below the cricoid cartilage differed substantially (1.00 mm c.f. 3.93 mm). The CTV54.25 coverage below the cricoid was then almost always lower, although the TCP of the accumulated dose was higher than the TCP of the voxel-wise minimum dose. CONCLUSIONS: Setup uncertainty setting of 2 mm is possible. The feasibility of using propagated CTVs for error determination is demonstrated.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Ng Wei Siang K, Both S, Oldehinkel E, et al. Assessment of residual geometrical errors of clinical target volumes and their impact on dose accumulation for head and neck radiotherapy. Radiother Oncol. 2023. PMID: 37597803. doi:10.1016/j.radonc.2023.109856

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。