双能CT衍生虚拟单能成像用于脑转移瘤靶区勾画的评估
这项回顾性分析纳入26例患者的37个脑转移瘤,比较双能CT虚拟单能成像(VMI)与人工120 kV CT的图像质量,并评估VMI对靶区勾画的影响。结果显示VMI在客观指标和主观评估上均优于120 kV CT,基于VMI勾画的靶区体积较MRI约小5%–10%。
要点
- VMI在病灶对比度、对比噪声比和信噪比上均显著高于120 kV CT(p<0.0001)。
- VMI图像对比度和病灶边界的主观评分显著优于120 kV CT(p<0.0001)。
- 基于VMI勾画的靶区体积较MRI约小5%–10%,可作为MRI靶区勾画的合理性核查。
核心结论
- VMI图像质量在客观和主观上均优于常规CT。
- VMI在立体定向放疗计划中具有显著优势,可改善脑转移瘤可见性并提供无几何失真的显示。
- 除对MRI靶区勾画进行合理性核查外,VMI可能提高靶区定义的可靠性和准确性,尤其在MRI存在成像不确定性时。
研究设计与样本
- 回顾性分析纳入26例接受MRI和DECT用于立体定向放疗计划的脑转移瘤患者,共37个脑转移瘤。
- 评估63 keV重建VMI与人工120 kV CT的病灶对比度、对比噪声比和信噪比。
- 由四名放射肿瘤学家在固定或自由脑窗VMI上勾画脑转移瘤,并用Dice相似系数与单纯基于MRI的勾画比较。
主要发现
- VMI的病灶对比度、对比噪声比和信噪比均显著高于120 kV CT(p<0.0001)。
- VMI的图像对比度和病灶边界主观评分显著优于120 kV CT(p<0.0001)。
- 无成像不确定性(无伪影、钙化或MRI显示不清)的转移瘤平均GTV/PTV Dice相似系数为0.87/0.9,有成像不确定性者为0.71/0.74。
- 基于VMI勾画的靶区体积较MRI约小5%–10%。
关键数值与推荐
- VMI病灶对比度、对比噪声比和信噪比显著高于120 kV CT(p<0.0001)。
- VMI图像对比度和病灶边界主观评分显著优于120 kV CT(p<0.0001)。
- 无成像不确定性转移瘤平均GTV Dice系数0.87、PTV Dice系数0.9;有成像不确定性者GTV 0.71、PTV 0.74。
- 基于VMI勾画的靶区体积较MRI约小5%–10%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Objective and subjective assessment of image quality of brain metastases on dual-energy computed tomography (DECT) virtual monoenergetic imaging (VMI) and its impact on target volume delineation. MATERIALS AND METHODS: 26 patients with 37 brain metastases receiving Magnetic Resonance Imaging (MRI) and DECT for stereotactic radiotherapy planning were included in this retrospective analysis. Lesion contrast (LC), contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed for reconstructed VMI at 63 keV and artificial 120 kV Computed Tomography (CT). Image contrast and demarcation of metastases between 120 kV CT, VMI and MRI were subjectively assessed. Brain metastases were delineated by four radiation oncologists on VMI with a fixed or free brain window and contours were compared to solely MRI-based delineation using the Dice similarity coefficient. RESULTS: LC, CNR and SNR were significantly higher in VMI than in 120 kV CT (p < 0.0001). Image contrast and lesion demarcation were significantly better on VMI compared to 120 kV CT (p < 0.0001). Mean gross tumor volume (GTV)/planning target volume (PTV) Dice similarity coefficients were 0.87/0.9 for metastases without imaging uncertainties (no artifacts, calcification or impaired visibility with MRI) but worse for metastases with imaging uncertainties (0.71/0.74). Target volumes delineated on VMI were around 5-10% smaller compared to MRI. CONCLUSION: Image quality of VMI is objectively and subjectively superior to conventional CT. VMI provides significant advantages in stereotactic radiotherapy planning with improved visibility of brain metastases and geometrically distortion-free representation of brain metastases. Beside a plausibility check of MRI-based target volume delineation, VMI might improve reliability and accuracy in target volume definition particularly in cases with imaging uncertainties with MRI.