磁共振图像引导放疗中前列腺床勾画共识指南的制定及其对观察者间变异性的影响评估

Development of Prostate Bed Delineation Consensus Guidelines for Magnetic Resonance Image-Guided Radiotherapy and Assessment of Its Effect on Interobserver Variability.
指南 / 共识 · Int J Radiat Oncol Biol Phys · 2023-08-25

研究纳入16名放射肿瘤学专家在3例来自Elekta Unity MR-Linac的MRI扫描上勾画前列腺床CTV,评估基线观察者间变异性(IOV),并通过文献综述和集体讨论制定国际共识指南,再评估指南对IOV的影响。结果显示指南制定后IOV下降,最大体积比从4.7降至3.1,体积变异系数从40%降至34%,平均Dice相似系数从0.72升至0.75,平均一致距离从3.63 mm降至2.95 mm。

要点

  • 基线勾画在上、下、前边界存在显著差异。
  • 共识指南制定后观察者间变异性下降但持续存在。
  • 作者认为教育项目、勾画图谱和指南细化可能进一步改善一致性。

核心结论

  • 国际泌尿生殖专家间前列腺床勾画存在观察者间变异性,但低于既往报道。
  • 已制定基于MRI的前列腺床勾画共识指南,勾画一致性有所改善。
  • IOV持续存在,作者认为教育项目、勾画图谱开发和指南进一步细化可能带来额外改善。

研究设计与样本

  • 研究要求参与者在3例来自Elekta Unity MR-Linac的MRI扫描上按各自常规实践勾画CTV。
  • 对放疗肿瘤学家的勾画进行视觉检查以发现差异,并使用重叠指标(Dice相似系数和Cohen's kappa)、距离指标(平均一致距离和Hausdorff距离)及体积测量与STAPLE轮廓进行观察者间比较。
  • 进行了根治性前列腺切除术后局部复发模式的文献综述,并与IOV结果一起呈现给参与者。
  • 集体构建共识指南后,使用这些指南重复进行IOV评估。
  • 最终分析纳入16名放射肿瘤学家的勾画。

主要发现

  • 视觉评估显示上、下、前边界存在显著差异。
  • 基线IOV评估显示重叠指标为中等一致性,而体积和距离指标显示较大变异性。
  • 在虚拟会议上建立了最佳前列腺床CTV边界的共识。
  • 指南制定后观察到IOV下降:最大体积比从4.7降至3.1,体积变异系数从40%降至34%。
  • 平均Dice相似系数从0.72升至0.75,平均一致距离从3.63 mm降至2.95 mm。

关键数值与推荐

  • 基线重叠指标显示中等一致性。
  • 指南制定后最大体积比从4.7降至3.1,体积变异系数从40%降至34%。
  • 指南制定后平均Dice相似系数从0.72升至0.75,平均一致距离从3.63 mm降至2.95 mm。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • IOV持续存在。
  • 作者认为教育项目、勾画图谱开发和指南进一步细化可能带来额外改善。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The use of magnetic resonance imaging (MRI) in radiotherapy planning is becoming more widespread, particularly with the emergence of MRI-guided radiotherapy systems. Existing guidelines for defining the prostate bed clinical target volume (CTV) show considerable heterogeneity. This study aimed to establish baseline interobserver variability (IOV) for prostate bed CTV contouring on MRI, develop international consensus guidelines, and evaluate its effect on IOV. METHODS AND MATERIALS: Participants delineated the CTV on 3 MRI scans, obtained from the Elekta Unity MR-Linac, as per their normal practice. Radiation oncologist contours were visually examined for discrepancies, and interobserver comparisons were evaluated against simultaneous truth and performance level estimation (STAPLE) contours using overlap metrics (Dice similarity coefficient and Cohen's kappa), distance metrics (mean distance to agreement and Hausdorff distance), and volume measurements. A literature review of postradical prostatectomy local recurrence patterns was performed and presented alongside IOV results to the participants. Consensus guidelines were collectively constructed, and IOV assessment was repeated using these guidelines. RESULTS: Sixteen radiation oncologists' contours were included in the final analysis. Visual evaluation demonstrated significant differences in the superior, inferior, and anterior borders. Baseline IOV assessment indicated moderate agreement for the overlap metrics while volume and distance metrics demonstrated greater variability. Consensus for optimal prostate bed CTV boundaries was established during a virtual meeting. After guideline development, a decrease in IOV was observed. The maximum volume ratio decreased from 4.7 to 3.1 and volume coefficient of variation reduced from 40% to 34%. The mean Dice similarity coefficient rose from 0.72 to 0.75 and the mean distance to agreement decreased from 3.63 to 2.95 mm. CONCLUSIONS: Interobserver variability in prostate bed contouring exists among international genitourinary experts, although this is lower than previously reported. Consensus guidelines for MRI-based prostate bed contouring have been developed, and this has resulted in an improvement in contouring concordance. However, IOV persists and strategies such as an education program, development of a contouring atlas, and further refinement of the guidelines may lead to additional improvements.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。