前列腺癌盆腔淋巴结放疗共识勾画指南:代表法语泌尿肿瘤放疗协作组(GFRU)
法国泌尿肿瘤放疗协作组(GFRU)基于86名放疗医师对高危淋巴结阴性前列腺癌病例的勾画数据,通过STAPLE法、Dice系数和Hausdorff距离定量评估,结合文献综述经专家讨论达成共识,提出易于应用、可重复且经实践验证的盆腔淋巴结临床靶区勾画指南。
要点
- 工作坊后STAPLE CTV与专家参考勾画的Dice系数从0.736(±0.084)升至0.823(±0.070)。
- 工作坊后Hausdorff距离从34.5 mm(±12.4)降至21.8 mm(±9.3)。
- 识别出4个观察者间变异显著的区域并达成共识。
核心结论
- 协作组提出易于应用、可重复且经实践验证的前列腺癌盆腔临床靶区勾画指南,可用于日常实践和临床试验。
研究设计与样本
- 由法语泌尿肿瘤放疗协作组(GFRU)制定共识指南,基于86名参加勾画工作坊的放疗医师对一例高危淋巴结阴性前列腺癌临床病例的淋巴结临床靶区数据集进行分析,并由3名GFRU专家定义参考勾画(CRef)。
主要发现
- STAPLE CTV体积为591 cc,参考勾画(CRef)体积为502 cc。
- STAPLE CTV与专家CRef的Dice系数在工作坊前为0.736(±0.084),工作坊后为0.823(±0.070),标准差从11.5%降至8.5%。
- STAPLE CTV与CRef的Hausdorff距离在工作坊前为34.5 mm(±12.4),工作坊后为21.8 mm(±9.3)。
- 识别出4个观察者间变异显著的区域,并达成共识。
关键数值与推荐
- 推荐条款原文未以条目形式报告。
临床怎么用
- 原文结论提出该指南可用于日常实践和临床试验。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Clinical target volume (CTV) delineation for pelvic lymph nodes in prostate cancer is currently based on 3 consensus guidelines with some inherent discrepancies. To improve the reproducibility in nodal delineation, the Francophone Group of Urological Radiotherapy (Groupe Francophone de Radiothérapie Urologique [GFRU]) worked toward proposing an easily applicable, reproducible, and practice-validated contouring guideline for pelvic nodal CTV. METHODS AND MATERIALS: The nodal CTV data sets of a high-risk node-negative prostate cancer clinical case contoured by 86 radiation oncologists participating in a GFRU contouring workshop were analyzed. CTV volumes were defined before and after a structured presentation of literature data on lymphatic drainage pathways and patterns of nodal involvement and relapse, illustrated using a reference contour (CRef) defined by 3 GFRU experts. The consistency between the participants' contours and CRef was assessed quantitively by means of the Simultaneous Truth and Performance Level Estimation (STAPLE) method, the Dice coefficient, and the Hausdorff distance and qualitatively using a count map. These results combined with the literature review were thoroughly discussed among GFRU experts to reach a consensus. RESULTS: From the 86 workshop participants, the volume of the STAPLE CTV was 591 cc compared with 502 cc for CRef. The Dice coefficient of the STAPLE CTV compared with the experts' CRef was 0.736 (±0.084) before and 0.823 (±0.070) after the workshop; the standard deviation decreased from 11.5% to 8.5% over the workshop. The Hausdorff distance of the STAPLE CTV compared with the CRef was 34.5 mm (±12.4) before the workshop and 21.8 mm (±9.3) after the workshop. Four areas of significant interobserver variability were identified, and a consensus was reached. CONCLUSIONS: Using a robust methodology, our cooperative group proposed an easily applicable, reproducible, and practice-validated guideline for the delineation of the pelvic CTV in prostate cancer, useful for implementation in daily practice and clinical trials.
引用
- De Hertogh O, Le Bihan G, Zilli T, et al. Consensus Delineation Guidelines for Pelvic Lymph Node Radiation Therapy of Prostate Cancer: On Behalf of the Francophone Group of Urological Radiation Therapy (GFRU). Int J Radiat Oncol Biol Phys. 2023. PMID: 37506982. doi:10.1016/j.ijrobp.2023.07.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。