指南与共识中枢神经肿瘤放疗放疗物理与技术

脑膜瘤放疗靶区勾画:ANOCEF共识指南

Target volume delineation for radiotherapy of meningiomas: an ANOCEF consensus guideline.
指南 / 共识 · Radiat Oncol · 2023-07-05

该指南由法语神经肿瘤学家协会(ANOCEF)的多学科脑肿瘤专家共识制定,采用三步法(综述、84项网络问卷、视频会议讨论)形成脑膜瘤放疗靶区勾画推荐。靶区边界基于CT和MRI可见解剖标志并考虑肿瘤延伸路径,旨在提高靶区定义的一致性。

要点

  • 靶区边界基于CT和MRI可见解剖标志定义,并考虑肿瘤延伸路径。
  • 推荐适用于脑膜瘤的辅助或根治性放疗,涵盖调强放疗和立体定向放疗技术。
  • 共识由ANOCEF多学科专家经三步法(综述、84项问卷、视频会议)形成,所有问题均达成共识。

核心结论

  • ANOCEF基于简单解剖边界提出了脑膜瘤靶区勾画的新推荐,预期将提高靶区定义的一致性。

研究设计与样本

  • 指南基于ANOCEF多学科脑肿瘤专家共识制定,采用三步法: steering组全面综述识别分歧问题、制定84项网络问卷、专家回答(前两轮在线,第三轮视频会议讨论剩余不确定问题)。

主要发现

  • 靶区边界使用CT和MRI可见解剖标志定义,并考虑肿瘤延伸路径。
  • 所有问卷问题均保持在共识范围内。

关键数值与推荐

  • 推荐适用于脑膜瘤的辅助或根治性放疗,涵盖调强放疗和立体定向放疗技术。
  • 靶区勾画推荐基于CT和MRI可见解剖标志及肿瘤延伸路径。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiotherapy is, with surgery, one of the main therapeutic treatment strategies for meningiomas. No prospective study has defined a consensus for the delineation of target volumes for meningioma radiotherapy. Therefore, target volume definition is mainly based on information from retrospective studies that include heterogeneous patient populations. The aim is to describe delineation guidelines for meningioma radiotherapy as an adjuvant or definitive treatment with intensity-modulated radiation therapy and stereotactic radiation therapy techniques. This guideline is based on a consensus endorsed by a multidisciplinary group of brain tumor experts, members of the Association of French-speaking Neuro-oncologists (ANOCEF). MATERIALS AND METHODS: A 3-step procedure was used. First, the steering group carried out a comprehensive review to identify divergent issues on meningiomas target volume delineation. Second, an 84-item web-questionnaire has been developed to precisely define meningioma target volume delineation in the most common clinical situations. Third, experts members of the ANOCEF were requested to answer. The first two rounds were completed online. A third round was carried out by videoconference to allow experts to debate and discuss the remaining uncertain questions. All questions remained in a consensus. RESULTS: Limits of the target volume were defined using visible landmarks on computed tomography and magnetic resonance imaging, considering the pathways of tumor extension. The purpose was to develop clear and precise recommendations on meningiomas target volumes. CONCLUSION: New recommendations for meningiomas delineation based on simple anatomic boundaries are proposed by the ANOCEF. Improvement in uniformity in target volume definition is expected.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Martz N, Salleron J, Dhermain F, et al. Target volume delineation for radiotherapy of meningiomas: an ANOCEF consensus guideline. Radiat Oncol. 2023. PMID: 37408055. doi:10.1186/s13014-023-02300-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。