文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

比较前列腺癌MRI引导在线自适应放疗中的自适应策略:对治疗边距的启示

Comparing adaptation strategies in MRI-guided online adaptive radiotherapy for prostate cancer: Implications for treatment margins.
PubMed 文献 · Radiother Oncol · 2023-06-20

本研究基于24例中高危前列腺癌患者的1.5T MR-Linac ATS治疗数据,比较ATP、ATR和ATS三种工作流程在分次内运动下覆盖CTVpros、CTVpros+sv和GTV所需的PTV边距。结果显示三种流程覆盖CTVpros所需边距均为2.5 mm;覆盖CTVpros+sv时ATP、ATR、ATS分别需5.0、4.0、3.5 mm;GTV覆盖在边距≤4.0 mm时从ATP到ATR改善。

要点

  • 三种流程覆盖CTVpros所需PTV边距相同,均为2.5 mm。
  • 覆盖CTVpros+sv时ATP、ATR、ATS分别需5.0、4.0、3.5 mm边距。
  • GTV覆盖在边距≤4.0 mm时从ATP到ATR改善。

核心结论

  • ATP、ATR和ATS工作流程在当前临床边距下对CTVpros的覆盖相同。
  • 对于CTVpros+sv,ATS表现最佳。
  • GTV覆盖通过针对前列腺旋转的额外自适应得到改善。

研究设计与样本

  • 使用24例中高危前列腺癌(PCa)患者的临床勾画数据,患者接受1.5 T MR-Linac上的ATS治疗。
  • 勾画数据在束流前和束流期间均可获得。
  • 通过从计划MRI到每日在线MRI的刚性变换自动生成模拟ATP和ATR工作流程的结构。
  • 临床GTV作为ATR GTV分析,仅模拟ATP GTV。
  • 使用各向同性边距0.0-5.0 mm生成计划靶体积(PTV)。

主要发现

  • 覆盖>95%的CTVpros所需PTV边距在所有工作流程中相等,均为2.5 mm。
  • 对于CTVpros+sv,所需边距在ATP、ATR和ATS工作流程中分别增加至5.0、4.0和3.5 mm。
  • 对于边距至4.0 mm,GTV覆盖从ATP到ATR改善。

关键数值与推荐

  • 覆盖>95%的CTVpros所需PTV边距:ATP 2.5 mm、ATR 2.5 mm、ATS 2.5 mm。
  • 覆盖>95%的CTVpros+sv所需PTV边距:ATP 5.0 mm、ATR 4.0 mm、ATS 3.5 mm。
  • GTV覆盖在边距≤4.0 mm时从ATP到ATR改善。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To quantify the difference in accuracy of adapt-to-position (ATP), adapt-to-rotation (ATR) and adapt-to-shape (ATS) workflows used in MRI-guided online adaptive radiotherapy for prostate carcinoma (PCa) by evaluating the margins required to accommodate intra-fraction motion of the clinical target volumes for prostate (CTVpros), prostate including seminal vesicles (CTVpros + sv) and gross tumor volume (GTV). MATERIALS AND METHODS: Clinical delineations of the CTVpros, CTVpros + sv and GTV of 24 patients with intermediate- and high-risk PCa, treated using ATS on a 1.5 T MR-Linac, were used for analysis. Delineations were available pre- and during beam-on. To simulate ATP and ATR workflows, we automatically generated the structures associated with these workflows using rigid transformations from the planning-MRI to the daily online MRIs. Clinical GTVs were analyzed as ATR GTVs and only ATP GTVs were simulated. Planning target volumes (PTVs) were generated with isotropic margins ranging 0.0-5.0 mm. The volumetric overlap was calculated between these PTVs and their corresponding clinical delineation on the MRI acquired during beam-on and averaged over all treatment fractions. RESULTS: The PTV margin required to cover > 95% of the CTVpros was equal (2.5 mm) for all workflows. For the CTVpros + sv, this margin increased to 5.0, 4.0 and 3.5 mm in the ATP, ATR and ATS workflow, respectively. GTV coverage improved from ATP to ATR for margins up to 4.0 mm. CONCLUSION: ATP, ATR and ATS workflows ensure equal coverage of the CTVpros for the current clinical margins. For the CTVpros + sv, ATS showed optimal performance. GTV coverage improves by additional adaptations to prostate rotations.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Dassen MG, Janssen T, Kusters M, et al. Comparing adaptation strategies in MRI-guided online adaptive radiotherapy for prostate cancer: Implications for treatment margins. Radiother Oncol. 2023. PMID: 37348607. doi:10.1016/j.radonc.2023.109761

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。