文献速递消化道肿瘤放疗放疗物理与技术

基于CBCT离线自适应放疗评估俯卧位部分弧VMAT在新辅助直肠癌放疗中的优势与稳健性

Advantages and robustness of partial VMAT with prone position for neoadjuvant rectal cancer evaluated by CBCT-based offline adaptive radiotherapy.
PubMed 文献 · Radiat Oncol · 2023-06-17

本研究回顾性分析31例直肠癌患者,在155幅CBCT图像上勾画结构,比较俯卧位全弧VMAT(F-VMAT)与部分弧VMAT(P-VMAT)的剂量学、放射生物学效应及稳健性。P-VMAT可降低膀胱和肠袋平均剂量,NTCP模型显示膀胱并发症概率(1.62±1.41 vs 1.88±2.08,P=0.041)和肠袋并发症概率(0.95±1.52 vs 1.28±1.70,P<0.001)均显著低于F-VMAT,且P-VMAT稳健性更优。

要点

  • 俯卧位P-VMAT较F-VMAT降低膀胱和肠袋平均剂量。
  • P-VMAT膀胱NTCP为1.62±1.41,低于F-VMAT的1.88±2.08(P=0.041)。
  • P-VMAT肠袋NTCP为0.95±1.52,低于F-VMAT的1.28±1.70(P<0.001)。

核心结论

  • 基于CBCT融合生成的合成CT,从剂量学、放射生物学效应和稳健性三方面分析,俯卧位P-VMAT均显示出比较优势。

研究设计与样本

  • 回顾性研究,纳入31例直肠癌患者,在155幅CBCT图像上勾画不同结构轮廓。
  • 对每例患者采用相同优化约束分别设计F-VMAT和P-VMAT计划,使用Acuros XB算法计算剂量分布和DVH以考虑空气腔。
  • 使用Velocity 4.0软件融合计划CT与CBCT获得合成CT,在Eclipse 15.6软件中用Acuros XB算法基于合成CT重新计算剂量。
  • 采用NTCP模型分析对膀胱和肠袋的放射生物学副作用。

主要发现

  • 在CTV覆盖98%的条件下,与F-VMAT相比,俯卧位P-VMAT能有效降低膀胱和肠袋的平均剂量。
  • NTCP模型显示,P-VMAT联合俯卧位计划技术的膀胱并发症概率显著低于F-VMAT(1.62±1.41 vs 1.88±2.08,P=0.041)。
  • NTCP模型显示,P-VMAT联合俯卧位计划技术的肠袋并发症概率显著低于F-VMAT(0.95±1.52 vs 1.28±1.70,P<0.001)。
  • 在稳健性方面,P-VMAT在CTV、膀胱和肠袋中观察到的剂量和NTCP变化更少,比F-VMAT更稳健。

关键数值与推荐

  • CTV覆盖率为98%。
  • 膀胱NTCP:P-VMAT为1.62±1.41,F-VMAT为1.88±2.08,P=0.041。
  • 肠袋NTCP:P-VMAT为0.95±1.52,F-VMAT为1.28±1.70,P<0.001。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: This study aims to explore the advantages and robustness of the partial arc combined with prone position planning technique for radiotherapy in rectal cancer patients. Adaptive radiotherapy is recalculated and accumulated on the synthesis CT (sCT) obtained by deformable image registration between planning CT and cone beam CT (CBCT). Full and partial volume modulation arc therapy (VMAT) with the prone position on gastrointestinal and urogenital toxicity, based on the probability of normal tissue complications (NTCP) model in rectal cancer patients were evaluated. MATERIALS AND METHODS: Thirty-one patients were studied retrospectively. The contours of different structures were outlined in 155 CBCT images. First, full VMAT (F-VMAT) and partial VMAT (P-VMAT) planning techniques were designed and calculated using the same optimization constraints for each individual patient. The Acuros XB (AXB) algorithm was used in order to generate more realistic dose distributions and DVH, considering the air cavities. Second, the Velocity 4.0 software was used to fuse the planning CT and CBCT to obtain the sCT. Then, the AXB algorithm was used in the Eclipse 15.6 software to conduct re-calculation based on the sCT to obtain the corresponding dose. Furthermore, the NTCP model was used to analyze its radiobiological side effects on the bladder and the bowel bag. RESULTS: With a CTV coverage of 98%, when compared with F-VMAT, P-VMAT with the prone position technique can effectively reduce the mean dose of the bladder and the bowel bag. The NTCP model showed that the P-VMAT combined with the prone planning technique resulted in a significantly lower complication probability of the bladder (1.88 ± 2.08 vs 1.62 ± 1.41, P = 0.041) and the bowel bag (1.28 ± 1.70 vs 0.95 ± 1.52, P < 0.001) than the F-VMAT. In terms of robustness, P-VMAT was more robust than F-VMAT, considering that less dose and NTCP variation was observed in the CTV, bladder and bowel bag. CONCLUSION: This study analyzed the advantages and robustness of the P-VMAT in the prone position from three aspects, based on the sCT fused by CBCT. Whether it is in regards to dosimetry, radiobiological effects or robustness, P-VMAT in the prone position has shown comparative advantages.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Zhang Z, Yu S, Peng F, et al. Advantages and robustness of partial VMAT with prone position for neoadjuvant rectal cancer evaluated by CBCT-based offline adaptive radiotherapy. Radiat Oncol. 2023. PMID: 37330508. doi:10.1186/s13014-023-02285-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。