文献速递乳腺癌放疗放疗物理与技术

腋窝淋巴结清扫术后即刻淋巴重建后放射治疗的前瞻性研究:剂量学影响分析

A Prospective Study of Radiation Therapy After Immediate Lymphatic Reconstruction: Analysis of the Dosimetric Implications.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2023-05-02

这项前瞻性研究纳入2020年10月至2022年6月接受腋窝淋巴结清扫联合即刻淋巴重建的13例患者,术中用旋转夹标记吻合口位置,采用三维适形技术联合对穿切线和斜野锁骨上照射进行计划。结果显示即刻淋巴重建吻合口常被直接照射并接受可观的辐射剂量,即使未刻意瞄准该部位。

要点

  • 13例患者中,12例即刻淋巴重建夹位于1站,1例位于2站。
  • 仅照射3站和锁骨上区的患者中,5例的即刻淋巴重建夹仍在照射野内,中位剂量3939 cGy(范围2025-4961 cGy)。
  • 全队列即刻淋巴重建夹中位剂量3939 cGy(范围139-4961 cGy),夹在任一照射野内时中位4275 cGy,夹在所有野外观时中位233 cGy。

核心结论

  • 采用三维适形技术时,即刻淋巴重建吻合口常被直接照射并接受可观的辐射剂量,即使该部位未被刻意瞄准。
  • 作者认为长期分析将有助于确定最小化吻合口辐射剂量是否能降低乳腺癌相关淋巴水肿的发生率。

研究设计与样本

  • 前瞻性研究,纳入2020年10月至2022年6月接受腋窝淋巴结清扫联合即刻淋巴重建的13例患者。
  • 术中置入旋转夹标记即刻淋巴重建吻合口部位,用于放疗计划识别。
  • 所有病例采用三维适形技术计划,使用对穿切线和斜野锁骨上照射。

主要发现

  • 区域淋巴结照射刻意针对腋窝1至3站和锁骨上淋巴结区者4例,仅限3站和锁骨上淋巴结者9例。
  • 即刻淋巴重建夹位于1站者12例,位于2站者1例。
  • 仅照射3站和锁骨上区的患者中,即刻淋巴重建夹仍在照射野内者5例,中位剂量3939 cGy(范围2025-4961 cGy)。
  • 全队列即刻淋巴重建夹中位剂量3939 cGy(范围139-4961 cGy)。
  • 即刻淋巴重建夹在任一照射野内时中位剂量4275 cGy(范围2025-4961 cGy),在所有野外观时中位剂量233 cGy(范围139-280 cGy)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Axillary lymph node dissection (ALND) and regional nodal irradiation (RNI) are the primary causes of breast cancer-related lymphedema (BCRL). Immediate lymphatic reconstruction (ILR) is a novel surgical procedure that reduces the incidence of BCRL after ALND. The ILR anastomosis is placed in a location thought to be outside the standard radiation therapy fields to prevent radiation-induced fibrosis of the reconstructed vessels; however, there is excess risk of BCRL from RNI even after ILR. The purpose of this study was to understand the radiation dose distribution in relation to the ILR anastomosis. METHODS AND MATERIALS: This prospective study included 13 patients treated with ALND/ILR from October 2020 to June 2022. A twirl clip deployed during surgery was used to identify the ILR anastomosis site during radiation treatment planning. All cases were planned using a 3D-conformal technique with opposed tangents and an obliqued supraclavicular (SCV) field. RESULTS: RNI deliberately targeted axillary Levels 1 to 3 and the SCV nodal region in 4 patients and was limited to Level 3 and SCV nodes in 9 patients. The ILR clip was located in Level 1 in 12 patients and Level 2 in 1 patient. In patients with radiation directed at only Level 3 and SCV, the ILR clip was still within the radiation field in 5 of these patients and received a median dose of 3939 cGy (range, 2025-4961 cGy). The median dose to the ILR clip was 3939 cGy (range, 139-4961 cGy) for the entire cohort. The median dose was 4275 cGy (range, 2025-4961 cGy) when the ILR clip was within any radiation field and 233 cGy (range, 139-280 cGy) when the clip was outside all fields. CONCLUSION: The ILR anastomosis was often directly irradiated with 3D-conformal techniques and received substantial radiation dose, even when the site was not deliberately targeted. Long-term analysis will help determine whether minimizing radiation dose to the anastomosis will decrease BCRL rates.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Spiegel DY, Willcox J, Friedman R, et al. A Prospective Study of Radiation Therapy After Immediate Lymphatic Reconstruction: Analysis of the Dosimetric Implications. Int J Radiat Oncol Biol Phys. 2023. PMID: 37141983. doi:10.1016/j.ijrobp.2023.04.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。