文献速递中枢神经肿瘤放疗放疗物理与技术

未切除脑转移瘤大分割立体定向放疗中同步整合加量概念的可行性

Feasibility of a simultaneously integrated boost concept for hypofractionated stereotactic radiotherapy of unresected brain metastases.
PubMed 文献 · Radiat Oncol · 2023-05-22

该回顾性计划研究纳入20个未切除脑转移瘤,比较同步整合加量(SIB)概念与经典80%处方概念的计划质量。SIB概念下GTV内异质性指数中位数0.0513,显著低于经典概念的0.0894(p=0.001),PTV周围剂量梯度不劣于经典概念。作者认为该SIB概念能更好地定义PTV内剂量分布,可考虑用于临床。

要点

  • 回顾性计划研究纳入20个未切除脑转移瘤,比较SIB与经典80%处方概念。
  • SIB概念GTV内异质性指数中位数0.0513,显著低于经典概念的0.0894(p=0.001)。
  • PTV周围剂量梯度不劣于经典概念,其余评估指标相当。

核心结论

  • 作者认为该立体定向SIB概念能更好地定义PTV内剂量分布,可考虑用于临床。

研究设计与样本

  • 回顾性计划研究,纳入20个未切除脑转移瘤,对每个转移瘤分别生成经典80%概念计划和SIB概念计划并进行配对比较。

主要发现

  • SIB概念GTV内异质性指数中位数0.0513(范围0.0397-0.0757),显著低于经典80%概念的0.0894(范围0.0447-0.1872),p=0.001。
  • PTV周围剂量梯度不劣于经典概念。
  • 其余评估指标两组相当。

关键数值与推荐

  • 经典80%概念:处方5次7 Gy于80% PTV周围等剂量线(D2%),并要求D98%(PTV)≥35 Gy。
  • SIB概念:GTV平均剂量5次8.5 Gy,并要求D98%(PTV)≥35 Gy。
  • GTV各向同性外扩3 mm形成PTV。

临床怎么用

  • 作者认为该SIB概念可考虑用于临床。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In stereotactic radiotherapy, dose is prescribed to an isodose surrounding the planning target volume (PTV). However, the desired dose inhomogeneity inside the PTV leaves the specific dose distribution to the gross tumor volume (GTV) unspecified. A simultaneously integrated boost (SIB) to the GTV could solve this shortcoming. In a retrospective planning study with 20 unresected brain metastases, a SIB approach was tested against the classical prescription. METHODS: For all metastases, the GTV was isotropically enlarged by 3 mm to a PTV. Two plans were generated, one according to the classical 80% concept with 5 times 7 Gy prescribed (on D2%) to the 80% PTV surrounding isodose (with D98%(PTV) ≥ 35 Gy), and the other one following a SIB concept with 5 times 8.5 Gy average GTV dose and with D98%(PTV) ≥ 35 Gy as additional requirement. Plan pairs were compared in terms of homogeneity inside GTV, high dose in PTV rim around GTV, and dose conformity and gradients around PTV using Wilcoxon matched pairs signed rank test. RESULTS: The SIB concept was superior to the classical 80% concept concerning dose homogeneity inside GTV: Heterogeneity index of GTV was in the SIB concept (median 0.0513, range 0.0397-0.0757) significantly (p = 0.001) lower than in the 80% concept (median 0.0894, range 0.0447-0.1872). Dose gradients around PTV were not inferior. The other examined measures were comparable. CONCLUSION: Our stereotactic SIB concept better defines the dose distribution inside PTV and can be considered for clinical use.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Kornhuber C, Ensminger S, Hübsch P, et al. Feasibility of a simultaneously integrated boost concept for hypofractionated stereotactic radiotherapy of unresected brain metastases. Radiat Oncol. 2023. PMID: 37217934. doi:10.1186/s13014-023-02266-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。