接受表面引导放疗的乳腺癌患者剂量覆盖与屏气分析

Dose coverage and breath-hold analysis of breast cancer patients treated with surface-guided radiotherapy.
PubMed 文献 · Radiat Oncol · 2023-04-20

本研究纳入84例接受局部或局部区域乳腺放疗的患者,采用表面引导放疗(SGRT)进行体位设置与监测,在前后位kV图像上以锁骨位置评估手臂摆位准确性,并在锥形束CT(CBCT)上计算实际交付剂量、进行屏气分析。结果显示84例中77例手臂摆位成功,平均锁骨旋转0.4°(±2.0°);全乳照射患者中89.8%的D98大于处方剂量的95%,胸壁照射患者中该比例为70.8%;屏气重复性与稳定性良好,未发现锁骨旋转与实际交付剂量之间的关系。

要点

  • 84例中77例手臂摆位成功,平均锁骨旋转0.4°(±2.0°)。
  • 全乳照射者89.8%的D98大于处方剂量95%,胸壁照射者为70.8%。
  • 屏气重复性与稳定性中位数分别为0.60 mm与0.20 mm。

核心结论

  • 采用SGRT可成功对乳腺癌患者进行体位设置,并重点关注手臂位置。
  • 基于CBCT计算的实际交付剂量是充分的,未发现锁骨旋转与实际交付剂量之间的关系。
  • 屏气分析显示屏气具有良好的重复性和稳定性。

研究设计与样本

  • 研究纳入84例接受局部或局部区域乳腺放疗的患者,使用SGRT进行体位设置与监测。
  • 在前后位kV图像上以锁骨位置研究手臂摆位准确性。
  • 在CBCT上计算实际交付剂量,并将CT与CBCT进行形变配准以把CT结构形变至CBCT。
  • 测定不同CTV体积中98%体积所接受的最小剂量占处方剂量的百分比(D98)。
  • 进行了广泛的屏气分析并给出相关参数的定义。

主要发现

  • 84例患者中77例基于锁骨旋转的手臂摆位成功,平均锁骨旋转为0.4°(±2.0°)。
  • 接受全乳照射的患者中89.8%的D98大于处方剂量的95%(D98 > 95%)。
  • 接受胸壁照射的患者中70.8%的D98大于处方剂量的95%。
  • 关于淋巴结CTV,至少95%的患者D98大于处方剂量的95%。
  • 屏气分析显示垂直、横向和纵向方向的平均残余摆位误差分别为-0.015(±0.90)mm、-0.18(±0.82)mm、-0.58(±1.1)mm。

关键数值与推荐

  • 手臂摆位成功以锁骨旋转为判定依据,84例中77例成功,平均锁骨旋转0.4°(±2.0°)。
  • 全乳照射患者中89.8%达到D98 > 95%,胸壁照射患者中70.8%达到D98 > 95%。
  • 淋巴结CTV方面,至少95%的患者达到D98 > 95%。
  • 屏气残余摆位误差:垂直-0.015(±0.90)mm、横向-0.18(±0.82)mm、纵向-0.58(±1.1)mm。
  • 屏气重复性中位数0.60 mm(95%CI [0.66-0.71] mm),稳定性中位数0.20 mm(95%CI [0.21-0.23] mm)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Surface-guided radiotherapy (SGRT) is used to ensure a reproducible patient set-up and for intra-fraction motion monitoring. The arm position of breast cancer patients is important, since this is related to the position of the surrounding lymph nodes. The aim of the study was to investigate the set-up accuracy of the arm of patients positioned using SGRT. Moreover, the actual delivered dose was investigated and an extensive breath-hold analysis was performed. METHODS: 84 patients who received local or locoregional breast radiation therapy were positioned and monitored using SGRT. The accuracy of the arm position, represented by the clavicle position, was studied on the anterior-posterior kV-image. To investigate the effect of changes in anatomy and patient set-up, the actual delivered dose was calculated on cone-beam CT-scans (CBCT). A deformable registration of the CT to the CBCT was applied to deform the structures of the CT onto the CBCT. The minimum dose in percentage of the prescribed dose that was received by 98% of different CTV volumes (D98) was determined. An extensive breath-hold analysis was performed and definitions for relevant parameters were given. RESULTS: The arm position of 77 out of 84 patients in total was successful, based on the clavicle rotation. The mean clavicle rotation was 0.4° (± 2.0°). For 89.8% of the patients who were irradiated on the whole-breast D98 was larger than 95% of the prescribed dose (D98 > 95%). D98 > 95% applied for 70.8% of the patients irradiated on the chest wall. Concerning the lymph node CTVs, D98 > 95% for at least 95% of the patients. The breath-hold analysis showed a mean residual setup error of - 0.015 (± 0.90), - 0.18 (± 0.82), - 0.58 (± 1.1) mm in vertical, lateral, and longitudinal direction, respectively. The reproducibility and stability of the breath-hold was good, with median 0.60 mm (95% confidence interval (CI) [0.66-0.71] mm) and 0.20 mm (95% CI 0.21-0.23] mm), respectively. CONCLUSIONS: Using SGRT we were able to position breast cancer patients successfully, with focus on the arm position. The actual delivered dose calculated on the CBCT was adequate and no relation between clavicle rotation and actual delivered dose was found. Moreover, breath-hold analysis showed a good reproducibility and stability of the breath-hold. Trial registration CCMO register NL69214.028.19.