文献速递胸部肿瘤放疗放疗物理与技术

用于放射治疗计划的肺静脉图谱

A pulmonary vein atlas for radiotherapy planning.
PubMed 文献 · Radiother Oncol · 2023-04-25

本研究由多学科团队制定肺静脉勾画图谱并在放疗计划CT上评估:5名放疗医生和2名放疗技师对5例接受1.8-2.75 Gy分次治疗的局部晚期肺癌患者的四维计划数据集勾画肺静脉,与参考轮廓比较。观察者轮廓与参考轮廓的几何和剂量学相似性为中等,总体平均Dice为0.80±0.02,平均剂量差异为0.79 Gy±0.71(1.46%±1.25)。

要点

  • 多学科团队制定了肺静脉勾画图谱及放疗CT勾画说明。
  • 观察者轮廓与参考轮廓总体平均Dice为0.80±0.02,相似性为中等。
  • 右上肺静脉平均Dice 0.83±0.02优于左上肺静脉0.80±0.03,下肺静脉均为0.78。

核心结论

  • 经多学科批准的肺静脉图谱在放疗计划中实现了可重复的勾画,支持该图谱用于未来涵盖心律失常终点的临床放疗心脏毒性研究。

研究设计与样本

  • 多学科团队从心脏病学和放射学文献中获取与心房颤动相关的大体和放射解剖信息,迭代制定放疗CT感兴趣区和勾画说明。
  • 5名放疗医生和2名放疗技师在5例接受1.8-2.75 Gy分次治疗的局部晚期肺癌患者的四维计划数据集上勾画肺静脉。
  • 采用几何和剂量学参数将勾画轮廓与研究者商定的参考轮廓进行比较。

主要发现

  • 肺静脉平均剂量为处方剂量的35%。
  • 观察者轮廓与参考轮廓的几何和剂量学相似性为中等,总体平均Dice为0.80±0.02。
  • 右上肺静脉平均Dice为0.83±0.02,优于左上肺静脉的0.80±0.03,下肺静脉平均Dice均为0.78。
  • 平均剂量的平均差异为0.79 Gy±0.71(1.46%±1.25)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Cardiac arrhythmia is a recognised potential complication of thoracic radiotherapy, but the responsible cardiac substructures for arrhythmogenesis have not been identified. Arrhythmogenic tissue is commonly located in the pulmonary veins (PVs) of cardiology patients with arrhythmia, however these structures are not currently considered organs-at-risk during radiotherapy planning. A standardised approach to their delineation was developed and evaluated. MATERIALS AND METHODS: The gross and radiological anatomy relevant to atrial fibrillation was derived from cardiology and radiology literature by a multidisciplinary team. A region of interest and contouring instructions for radiotherapy computed tomography scans were iteratively developed and subsequently evaluated. Radiation oncologists (n = 5) and radiation technologists (n = 2) contoured the PVs on the four-dimensional planning datasets of five patients with locally advanced lung cancer treated with 1.8-2.75 Gy fractions. Contours were compared to reference contours agreed by the researchers using geometric and dosimetric parameters. RESULTS: The mean dose to the PVs was 35% prescription dose. Geometric and dosimetric similarity of the observer contours with reference contours was fair, with an overall mean Dice of 0.80 ± 0.02. The right superior PV (mean DSC 0.83 ± 0.02) had better overlap than the left (mean DSC 0.80 ± 0.03), but the inferior PVs were equivalent (mean DSC of 0.78). The mean difference in mean dose was 0.79 Gy ± 0.71 (1.46% ± 1.25). CONCLUSION: A PV atlas with multidisciplinary approval led to reproducible delineation for radiotherapy planning, supporting the utility of the atlas in future clinical radiotherapy cardiotoxicity research encompassing arrhythmia endpoints.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Walls GM, McCann C, Ball P, et al. A pulmonary vein atlas for radiotherapy planning. Radiother Oncol. 2023. PMID: 37105303. doi:10.1016/j.radonc.2023.109680

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。