文献速递头颈部肿瘤放疗放疗物理与技术

0.35 T与1.5 T磁场对喉癌MR引导放疗中浅表剂量的影响

Effect of 0.35 T and 1.5 T magnetic fields on superficial dose in MR-guided radiotherapy of laryngeal cancer.
PubMed 文献 · Clin Transl Radiat Oncol · 2023-04-01

这项双中心剂量学研究纳入14例喉癌病例,PTV达皮肤表面,比较两种VMAT计划(加与不加5 mm bolus)和三种IMRT MRgRT计划(0.35 T、1.5 T、0 T,均不加bolus)的剂量分布,并用胶片测量验证。结果显示加bolus的VMAT与0.35 T、1.5 T MRgRT计划对PTV最浅表3-5 mm覆盖相似,而不加bolus的VMAT与0 T计划通常未达到该区域覆盖。作者认为两种商用MR-linac的电子回旋效应可为喉癌MRgRT计划提供足够的浅表组织覆盖。

要点

  • 加bolus的VMAT与0.35 T、1.5 T MRgRT计划对PTV最浅表3-5 mm覆盖相似。
  • 不加bolus的VMAT与0 T计划通常未达到PTV最浅表3-5 mm覆盖。
  • 胶片测量验证结果,相对误差未超过计划间计算差异。

核心结论

  • 两种商用MR-linac变体的电子回旋效应可为喉癌MRgRT计划提供足够的浅表组织层覆盖。

研究设计与样本

  • 双中心剂量学研究纳入14例喉癌病例,PTV达皮肤表面。
  • 每例患者比较五种计划:两种VMAT计划(加与不加5 mm bolus)和三种IMRT MRgRT计划(0.35 T、1.5 T、0 T,均不加bolus)。
  • 剂量分布用胶片测量验证。

主要发现

  • 加bolus的VMAT计划与0.35 T、1.5 T MRgRT计划对PTV最浅表3-5 mm覆盖相似。
  • 不加bolus的VMAT计划与0 T计划通常未达到PTV最浅表3-5 mm覆盖。
  • 体模胶片测量证实上述结果,相对误差未超过计划间计算差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Treatment of head and neck cancer on linear accelerators with on-board magnetic resonance imaging (MR-linac) might be beneficial to reduce side effects and increase accuracy. For many head and neck cancer patients, dose coverage of the often superficially located planning target volumes (PTVs) is required. This study examines the impact of the electron return effect (ERE) on the surface dose in MR-guided radiotherapy (MRgRT) compared to conventional radiotherapy. MATERIALS AND METHODS: For this bicentric dosimetric study, 14 cases of laryngeal carcinomas with PTVs reaching up to the skin surface were included. For each patient, five different plans were compared, two VMAT plans (with and without a 5 mm bolus) and three IMRT MRgRT plans (0.35 T, 1.5 T and 0 T, each without bolus). Dose distributions were also validated with film measurements. RESULTS: A similar coverage on the most superficial 3-5 mm of the PTV was achieved in the VMAT plans with bolus and the MRgRT plans for both 0.35 T and 1.5 T. However, coverage on this region was usually not achieved for VMAT without bolus and the 0 T plans. The film measurements on phantoms confirmed the results with the relative error never exceeding the calculated differences between the plans. CONCLUSION: The present study could demonstrate that the ERE for both commercially available MR-linac variants provides sufficient coverage of the superficial tissue layers in MRgRT-plans for laryngeal carcinoma.

来源:Clin Transl Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Conrad M, Dal Bello R, van Timmeren JE, et al. Effect of 0.35 T and 1.5 T magnetic fields on superficial dose in MR-guided radiotherapy of laryngeal cancer. Clin Transl Radiat Oncol. 2023. PMID: 37090848. doi:10.1016/j.ctro.2023.100624

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。