根治性前列腺切除术后前列腺床磁共振引导下减边立体定向放疗中自适应计划的作用:一项二期临床试验的事后分析
该二期临床试验事后分析纳入31例根治性前列腺切除术后接受前列腺床磁共振引导下立体定向放疗(30-34 Gy/5次)的患者,回顾性勾画155次每日治疗前MRI,评估分次间解剖变化及自适应计划的作用。结果显示多数分次未满足靶区或危及器官剂量约束,但自适应计划后所有分次均满足靶区约束,120/155次分次满足全部危及器官约束,作者认为前列腺床立体定向放疗应常规考虑自适应计划。
要点
- 155次分次中145次(93.5%)满足CTV V95%>93%,75次(48.4%)至少违反一项危及器官剂量约束。
- 83/155次分次(53.5%)符合自适应计划标准,涉及24/31例患者(77.4%)。
- 自适应计划后所有分次满足CTV V95%>93%和PTV V95%>90%,120/155次分次(77.4%)满足全部危及器官约束。
核心结论
- 由于分次间解剖存在显著变化,多数分次未能同时满足靶区体积和危及器官约束,但自适应计划能有效克服这些解剖变化,作者认为前列腺床立体定向放疗应常规考虑自适应计划。
研究设计与样本
- 二期临床试验的事后分析,31例患者接受前列腺床磁共振引导下立体定向放疗,总剂量30-34 Gy分5次给予。
- 在155次每日治疗前MRI上回顾性勾画危及器官、临床靶区(CTV)和计划靶区(PTV),并与初始计划轮廓进行几何比较。
- 对未满足预设剂量约束的分次模拟自适应计划并重新评估。
主要发现
- CTV体积中位变化0.48%,膀胱体积中位变化-24.5%,直肠体积中位变化6.95%。
- CTV、膀胱、直肠的中位DSC分别为0.89、0.79、0.76。
- 145/155次分次(93.5%)满足CTV V95%>93%,75/155次分次(48.4%)至少违反一项危及器官剂量约束。
- 83/155次分次(53.5%)符合自适应计划标准,涉及24/31例患者(77.4%)。
- 自适应计划后所有分次满足CTV V95%>93%和PTV V95%>90%,120/155次分次(77.4%)满足全部危及器官约束。
关键数值与推荐
- 评估的剂量约束包括:CTV V95%>93%、PTV V95%>90%、膀胱Dmax<36.7 Gy、膀胱V32.5 Gy<35%、直肠Dmax<36.7 Gy、直肠V27.5 Gy<45%、直肠V32.5 Gy<30%、直肠壁V24 Gy<50%。
临床怎么用
- 作者认为,前列腺床立体定向放疗应常规考虑自适应计划。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: We examined the interfractional variations of clinical target volumes (CTVs), planning target volumes (PTVs), and organs-at-risk (OARs) in patients receiving MRI-guided stereotactic body radiotherapy (SBRT) to the prostate bed and evaluated the potential role of adaptive planning. MATERIALS AND METHODS: 31 patients received 30-34 Gy in five fractions to the prostate bed on a phase II clinical trial. OARs, CTVs, and PTVs were retrospectively contoured on daily pretreatment MRIs (n = 155). Geometric comparisons were made between initial planning contours and daily pretreatment contours. Predicted treatment plans for each fraction were evaluated using the following constraints: CTV V95%>93%, PTV V95%>90%, bladder Dmax < 36.7 Gy, bladder V32.5 Gy < 35%, rectum Dmax < 36.7 Gy, rectum V27.5 Gy < 45%, rectum 32.5 Gy < 30%, and rectal wall V24Gy < 50%. Adaptive planning was simulated for all fractions that failed to meet these criteria. Plans were then re-evaluated. RESULTS: Median change in volume was 0.48% for CTV, -24.5% for bladder, and 6.95% for rectum. Median DSC was 0.89 for CTV, 0.79 for bladder, and 0.76 for rectum. 145/155 fractions (93.5%) met CTV V95%>93%. 75/155 fractions (48.4%) failed at least one OAR dose constraint. Overall, 83/155 fractions (53.5%) met criteria for adapting planning. This affected 24/31 patients (77.4%). Following adaptive planning, all fractions met CTV V95%>93% and PTV V95%>90% and 120/155 fractions (77.4%) met all OAR constraints. CONCLUSION: Due to significant interfractional variations in anatomy, a majority of fractions failed to meet both target volume and OAR constraints. However, adaptive planning was effective in overcoming these anatomic changes. Adaptive planning should be routinely considered in prostate bed SBRT.
引用
- Nikitas J, Smith LM, Gao Y, et al. The role of adaptive planning in margin-reduced, MRI-guided stereotactic body radiotherapy to the prostate bed following radical prostatectomy: Post-hoc analysis of a phase II clinical trial. Radiother Oncol. 2023. PMID: 36934894. doi:10.1016/j.radonc.2023.109631
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。