文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

日本临床肿瘤学组JCOG1402研究:宫颈癌术后调强放疗前瞻性多中心临床试验中试运行与个体病例复核的计划质量关联

Plan quality association between dummy run and individual case review in a prospective multi-institutional clinical trial of postoperative cervical cancer patients treated with intensity-modulated radiotherapy: Japan clinical Oncology Group study (JCOG1402).
PubMed 文献 · Radiother Oncol · 2023-03-18

日本临床肿瘤学组(JCOG)1402研究在宫颈癌术后调强放疗(IMRT)多中心试验中,采用统一质量保证(QA)程序,对214份计划行个体病例复核(ICR),并与入组前试运行(DR)的偏差模式比较。ICR中检出288项偏差和9项违规,偏差模式与DR相似,临床靶区(CTV)勾画偏差最常见(DR 50%,ICR 37%),每份计划约1.4项偏差/违规,低于DR。作者认为需与参与机构进行更具体的面对面会议以维持IMRT质量。

要点

  • 214份计划ICR检出288项偏差和9项违规,偏差模式与DR相似。
  • CTV勾画偏差最常见,DR为50%,ICR为37%。
  • ICR每份计划约1.4项偏差/违规,低于DR。

核心结论

  • 作者开发的QA程序在DR和ICR中通用,查明了治疗计划中的陷阱。
  • 尽管ICR中仍常见CTV勾画偏差,但较DR减少。
  • 作者认为需要与参与机构进行更具体的面对面会议,以维持临床方案中IMRT的质量。

研究设计与样本

  • 日本临床肿瘤学组(JCOG)1402为高危子宫颈癌患者术后IMRT的多中心临床试验。
  • 对214份计划采用与DR相同的QA程序进行ICR,并将偏差与DR所示偏差比较。
  • 与参与机构医生举行了15次面对面会议以提供反馈。

主要发现

  • 214份计划中检出288项偏差和9项违规。
  • ICR中观察到的偏差模式与DR相似。
  • CTV勾画频繁偏差:DR为50%,ICR为37%。
  • ICR中每份计划约1.4项偏差/违规,低于DR。
  • 9项违规包括CTV勾画不准确和PTV margin不当,因剂量覆盖不足存在局部区域失败风险。

局限性

  • 作者结论指出,需要与参与机构进行更具体的面对面会议,以维持临床方案中IMRT的质量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: The Japan Clinical Oncology Group (JCOG) 1402 conducted a multicenter clinical trial of postoperative intensity-modulated radiotherapy (IMRT) for high-risk uterine cervical cancer patients. We assess effectiveness of the quality assurance (QA) program in central review through dummy runs (DRs) performed before patient enrollment and post-treatment individual case review (ICR), and clarify the pitfalls in treatment planning. MATERIAL AND METHODS: The ICRs were conducted using the same QA program as the DR for 214 plans. The deviations were compared with those demonstrated in the DRs, and the pitfalls were clarified. Fifteen face-to-face meetings were held with physicians at participating institutions to provide feedback. RESULTS: Two-hundred and eighty-eight deviations and nine violations were detected in the 214 plans. The patterns of the deviations observed in the ICRs were similar to that in the DR. Frequent deviations were observed in clinical target volume (CTV) delineations, 50% in the DRs and 37% in the ICRs, respectively. In the ICRs, approximately 1.4 deviations/violations were observed per plan, which was lower than DR. Nine violations included inaccurate CTV delineation and improper PTV (planning target volume) margin, which had risks in loco-regional failures by inadequate dose coverage. CONCLUSIONS: Our developed QA program commonly used in DR and ICR clarified the pitfalls in treatment plans. Although the frequent deviations in CTV delineations were observed in the ICR, the deviations decreased compared to that in the DR. More specified face-to-face meetings with participating institutions will be necessary to maintain the quality of IMRT in the clinical protocol.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Okamoto H, Murakami N, Isohashi F, et al. Plan quality association between dummy run and individual case review in a prospective multi-institutional clinical trial of postoperative cervical cancer patients treated with intensity-modulated radiotherapy: Japan clinical Oncology Group study (JCOG1402). Radiother Oncol. 2023. PMID: 36934892. doi:10.1016/j.radonc.2023.109630

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。