自愿与机械诱导深吸气屏气用于左侧乳腺癌:一项随机对照试验
该随机、开放标签、多中心、单机构非劣效性试验将66例拟行仰卧位左侧全乳辅助放疗的患者等分至机械诱导深吸气屏气(MANIV-DIBH)组与表面引导放疗(SGRT)引导的自愿深吸气屏气(sDIBH)组。共同主要终点为乳腺位置稳定性和可重复性,非劣效界值1 mm。两组的乳腺位置可重复性和稳定性差异在亚毫米水平(非劣效性p < 0.001),MANIV-DIBH组在左前降支近最大剂量、平均剂量及左心室V5Gy、左肺V20Gy和V30Gy方面更优,耐受性和治疗时间相似。
要点
- MANIV-DIBH与sDIBH在乳腺位置稳定性和可重复性上差异为亚毫米级,非劣效性p < 0.001。
核心结论
- 机械通气提供的靶区照射精度与SGRT引导的自愿DIBH相同,同时更好地保护和重新定位危及器官。
研究设计与样本
- 随机、开放标签、多中心、单机构非劣效性试验,66例适合仰卧位左侧全乳辅助放疗的患者等分至MANIV-DIBH组与SGRT引导的sDIBH组。
主要发现
- 两组乳腺位置可重复性和稳定性差异在亚毫米水平(非劣效性p < 0.001)。
- MANIV-DIBH组观察到更好的心脏分次间位置可重复性,耐受性和治疗时间两组相似。
关键数值与推荐
- 共同主要终点为乳腺位置稳定性和可重复性,非劣效界值1 mm。
- 次要终点为通过验证量表每日评估的耐受性、治疗时间、危及器官剂量及其分次间位置可重复性。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Deep inspiration breath-hold (DIBH) protects critical organs-at-risk (OARs) for adjuvant breast radiotherapy. Guidance systems e.g. surface guided radiation therapy (SGRT) improve the positional breast reproducibility and stability during DIBH. In parallel, OARs sparing with DIBH is enhanced through different techniques e.g. prone position, continuous positive airway pressure (CPAP). By inducing repeated DIBH with the same level of positive pressure, mechanically-assisted and non-invasive ventilation (MANIV) could potentially combine these DIBH optimizations. MATERIALS AND METHODS: We conducted a randomized, open-label, multicenter and single-institution non-inferiority trial. Sixty-six patients eligible for adjuvant left whole-breast radiotherapy in supine position were equally assigned between mechanically-induced DIBH (MANIV-DIBH) and voluntary DIBH guided by SGRT (sDIBH). The co-primary endpoints were positional breast stability and reproducibility with a non-inferiority margin of 1 mm. Secondary endpoints were tolerance assessed daily via validated scales, treatment time, dose to OARs and their inter-fraction positional reproducibility. RESULTS: Differences between both arms for positional breast reproducibility and stability occurred at a sub-millimetric level (p < 0.001 for non-inferiority). The left anterior descending artery near-max dose (14,6 ± 12,0 Gy vs. 7,7 ± 7,1 Gy, p = 0,018) and mean dose (5,0 ± 3,5 Gy vs. 3,0 ± 2,0 Gy, p = 0,009) were improved with MANIV-DIBH. The same applied for the V5Gy of the left ventricle (2,4 ± 4,1 % vs. 0,8 ± 1,6 %, p = 0,001) as well as for the left lung V20Gy (11,4 ± 2,8 % vs. 9,7 ± 2,7 %, p = 0,019) and V30Gy (8,0 ± 2,6 % vs. 6,5 ± 2,3 %, p = 0,0018). Better heart's inter-fraction positional reproducibility was observed with MANIV-DIBH. Tolerance and treatment time were similar. CONCLUSION: Mechanical ventilation provides the same target irradiation accuracy as with SGRT while better protecting and repositioning OARs.
引用
- Vander Veken L, Van Ooteghem G, Razavi A, et al. Voluntary versus mechanically-induced deep inspiration breath-hold for left breast cancer: A randomized controlled trial. Radiother Oncol. 2023. PMID: 36898583. doi:10.1016/j.radonc.2023.109598
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。