文献速递胸部肿瘤放疗放疗物理与技术

质子立体定向体部放疗FLASH治疗计划的集成物理优化框架:利用患者特异性脊形滤波器实现剂量、剂量率与线性能量转移优化

An Integrated Physical Optimization Framework for Proton Stereotactic Body Radiation Therapy FLASH Treatment Planning Allows Dose, Dose Rate, and Linear Energy Transfer Optimization Using Patient-Specific Ridge Filters.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2023-02-01

本研究开发了一种逆向计划软件,设计患者特异性脊形滤波器,将固定能量250 MeV束流的布拉格峰扩展至近端束流特异性计划靶区,并利用基于Geant4的蒙特卡洛计算引擎提供剂量与LET影响矩阵。采用matRAD进行计划优化,在最小监测单位约束下同时考虑剂量、剂量率和LET的IPO-IMPT目标函数。对3例肺癌患者设计脊形滤波器并优化计划,结果显示IPO-IMPT框架相对于IMPT计划通过降低LET和增加剂量率选择性保护危及器官,稀疏优化脊形滤波器在剂量率方面优于规则间隔脊形滤波器。

要点

  • 开发了集成物理优化框架用于质子FLASH立体定向体部放疗计划。
  • 患者特异性脊形滤波器将250 MeV束流布拉格峰扩展至近端束流特异性计划靶区。
  • 对3例肺癌患者,IPO-IMPT相对IMPT降低LET并增加剂量率以保护危及器官。

核心结论

  • 该概念验证研究证明使用IPO-IMPT框架实现质子FLASH立体定向体部放疗的可行性,可同时考虑剂量、DADR和LETd。

研究设计与样本

  • 研究开发逆向计划软件设计患者特异性脊形滤波器,使用基于Geant4的蒙特卡洛计算引擎提供剂量和LET影响矩阵。
  • 计划优化使用matRAD,采用IPO-IMPT目标函数同时考虑剂量、剂量率和LET,并纳入最小监测单位约束。
  • 框架支持设计规则间隔和稀疏优化脊形滤波器,后者省略部分针以加快投照并选择性优化LET。
  • 对3例肺癌患者设计脊形滤波器并使用IPO-IMPT优化计划以演示框架。

主要发现

  • IPO-IMPT框架相对于IMPT计划通过降低LET和增加剂量率选择性保护危及器官。
  • 稀疏优化脊形滤波器在剂量率方面优于规则间隔脊形滤波器。
  • 根据优先参数不同,针对心脏、肺和食管的评估结构显示剂量、DADR和LETd的体积分布和直方图具有高水平FLASH剂量率覆盖和/或降低的LETd,同时保持束流特异性计划靶区内的剂量覆盖。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Patient-specific ridge filters provide a passive means to modulate proton energy to obtain a conformal dose. Here we describe a new framework for optimization of filter design and spot maps to meet the unique demands of ultrahigh-dose-rate (FLASH) radiation therapy. We demonstrate an integrated physical optimization Intensity-modulated proton therapy (IMPT) (IPO-IMPT) approach for optimization of dose, dose-averaged dose rate (DADR), and dose-averaged linear energy transfer (LETd). METHODS AND MATERIALS: We developed an inverse planning software to design patient-specific ridge filters that spread the Bragg peak from a fixed-energy, 250-MeV beam to a proximal beam-specific planning target volume. The software defines patient-specific ridge filter pin shapes and uses a Monte Carlo calculation engine, based on Geant4, to provide dose and LET influence matrices. Plan optimization, using matRAD, accommodates the IPO-IMPT objective function considering dose, dose rate, and LET simultaneously with minimum monitor unit constraints. The framework enables design of both regularly spaced and sparse-optimized ridge filters, from which some pins are omitted to allow faster delivery and selective LET optimization. To demonstrate the framework, we designed ridge filters for 3 example patients with lung cancer and optimized the plans using IPO-IMPT. RESULTS: The IPO-IMPT framework selectively spared the organs at risk by reducing LET and increasing dose rate, relative to IMPT planning. Sparse-optimized ridge filters were superior to regularly spaced ridge filters in dose rate. Depending on which parameter is prioritized, volume distributions and histograms for dose, DADR, and LETd, using evaluation structures specific to heart, lung, and esophagus, show high levels of FLASH dose-rate coverage and/or reduced LETd, while maintaining dose coverage within the beam specific planning target volume. CONCLUSIONS: This proof-of-concept study demonstrates the feasibility of using an IPO-IMPT framework to accomplish proton FLASH stereotactic body proton therapy, accounting for dose, DADR, and LETd simultaneously.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Liu R, Charyyev S, Wahl N, et al. An Integrated Physical Optimization Framework for Proton Stereotactic Body Radiation Therapy FLASH Treatment Planning Allows Dose, Dose Rate, and Linear Energy Transfer Optimization Using Patient-Specific Ridge Filters. Int J Radiat Oncol Biol Phys. 2023. PMID: 36736634. doi:10.1016/j.ijrobp.2023.01.048

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。