基于肿瘤几何与体形变化开发机器学习预测程序以在头颈部容积调强弧形治疗中实施自适应放疗
本研究纳入47例非自适应放疗组和21例因形变需自适应放疗的头颈癌容积调强弧形治疗患者,构建含1112个六维列表的数据集,采用支持向量机与k近邻预测自适应放疗需求。包含至20次分次CTV变化量和变化率的列表分类准确率分别为0.963和0.967。该程序基于锥形束CT分析的形变随时间变化,以超过90%的准确率预测自适应放疗需求。
要点
- 纳入47例非自适应放疗组和21例自适应放疗组头颈癌容积调强弧形治疗患者。
- 包含至20次分次CTV变化量和变化率的列表,支持向量机与k近邻分类准确率分别为0.963和0.967。
- 程序基于锥形束CT分析的形变随时间变化,以超过90%准确率预测自适应放疗需求。
核心结论
- 该程序基于锥形束CT分析中至20次分次的形变随时间变化,以超过90%的准确率预测自适应放疗需求,可能为基于治疗期间变化量客观决定实施自适应放疗提供重要支持。
研究设计与样本
- 研究纳入47例非自适应放疗组和21例因形变需自适应放疗的头颈癌容积调强弧形治疗患者,为每位患者创建1112个六维列表,包括照射次数、临床靶区体积(CTV)变化量、CTV变化率、口腔平均剂量、年龄和体重指数,采用支持向量机和k近邻进行机器学习,随机提取的测试数据数量从1到9变化并计算平均准确率评分。
主要发现
- 包含至20次分次CTV变化量和变化率的列表,支持向量机分类准确率为0.963,k近邻分类准确率为0.967。
关键数值与推荐
- 包含至20次分次CTV变化量和变化率的列表,支持向量机分类准确率为0.963,k近邻分类准确率为0.967。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: During radiation therapy for head and neck cancer using volumetric modulated arc therapy, excessive dosing or underdosing occurs as a result of the decrease in tumor volume and changes in body weight. Adaptive radiation therapy (ART) is performed when significant changes are observed; however, the decision to implement ART depends on the oncologist's subjective judgment. The purpose of this study was to present objective indicators for ART and develop a program to predict the need for ART. METHODS AND MATERIALS: The study included 47 patients in the non-ART group and 21 patients in the ART group with shape changes. Patients who received ART could not be covered with the prescribed radiation therapy dose due to shape changes. For each patient, 1112 6-dimensional lists were created, including the number of irradiations, amount of change in the clinical target volume (CTV), rate of change in CTV, mean oral cavity dose, age, and body mass index. Support vector machine and k-nearest neighbor were used for machine learning. The random number of test data to be extracted varied from 1 to 9, and a mean accuracy score was calculated. These programs could predict the need for ART if the accuracy score was high. RESULTS: The classification accuracy of the list, including the amount of change in the CTV and rate of change in CTV up to 20 fractions, was 0.963 and 0.967 for support vector machine and k-nearest neighbor, respectively. CONCLUSIONS: This program predicted the need for ART with more than 90% accuracy based on shape changes over time in cone beam computed tomography analysis for up to 20 fractions. This may provide significant support for objective decisions to implement ART based on the amount of change over time during treatment.
引用
- Rachi T, Ariji T, Takahashi S, et al. Development of Machine-Learning Prediction Programs for Delivering Adaptive Radiation Therapy With Tumor Geometry and Body Shape Changes in Head and Neck Volumetric Modulated Arc Therapy. Adv Radiat Oncol. 2023. PMID: 36817412. doi:10.1016/j.adro.2023.101172
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。