文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

宫颈癌放疗中基于CBCT图像的可变形图像配准与合成CT生成对危及器官的剂量学比较

Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy.
PubMed 文献 · Radiat Oncol · 2023-01-05

本研究收集40对计划CT与CBCT图像,比较基于3D多阶段配准网络的可变形图像配准(DIR)与基于2D CycleGAN的合成CT(sCT)生成两种方法在宫颈癌放疗中的几何与剂量学精度。以DosedpCT为参考时,DosesCT与DosedpCT的全局γ通过率为99.66%±0.34%,而DoseCBCT与DosedpCT为85.92%±7.56%;sCT轮廓在小肠、直肠、膀胱和脊髓中误差更低,尤其当计划CT与CBCT体积差异较大时。

要点

  • 在1%/1 mm标准、10%低剂量阈值下,DosesCT与DosedpCT的全局γ通过率为99.66%±0.34%。
  • 同条件下DoseCBCT与DosedpCT的全局γ通过率为85.92%±7.56%。
  • 以DosedpCT为均匀剂量分布时,sCT轮廓在小肠、直肠、膀胱和脊髓中误差低于dpCT轮廓。

核心结论

  • 对于宫颈癌放疗,DIR方法与sCT生成可产生相似的精确剂量分布,但当计划CT与CBCT差异较大时sCT轮廓精度更高。

研究设计与样本

  • 本研究收集40对计划CT与CBCT图像,评估DIR与sCT生成的精度。
  • DIR方法基于3D多阶段配准网络,使用150对计划CT-CBCT图像训练。
  • sCT生成方法基于2D循环一致性对抗网络(CycleGAN),使用6000对计划CT-CBCT切片训练。
  • 剂量通过基于GPU的蒙特卡罗剂量代码ArcherQA在CBCT、pCT、变形pCT(dpCT)和sCT图像上重新计算,得到DoseCBCT、DosepCT、DosedpCT和DosesCT。
  • 危及器官包括小肠、直肠、膀胱、脊髓、股骨头和骨髓;CBCT与pCT轮廓手动勾画,dpCT轮廓通过变形矢量场传播,sCT轮廓自动分割后手动校正。

主要发现

  • 在1%/1 mm标准、10%低剂量阈值下,DosesCT与DosedpCT的全局γ通过率为99.66%±0.34%,而DoseCBCT与DosedpCT为85.92%±7.56%。
  • 以DosedpCT为均匀剂量分布时,与CBCT轮廓相比,dpCT和sCT轮廓在股骨头和骨髓中误差相当。
  • sCT轮廓在小肠、直肠、膀胱和脊髓中误差更低,尤其对于计划CT与CBCT体积差异较大的情况。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Anatomical variations existing in cervical cancer radiotherapy treatment can be monitored by cone-beam computed tomography (CBCT) images. Deformable image registration (DIR) from planning CT (pCT) to CBCT images and synthetic CT (sCT) image generation based on CBCT are two methods for improving the quality of CBCT images. This study aims to compare the accuracy of these two approaches geometrically and dosimetrically in cervical cancer radiotherapy. METHODS: In this study, 40 paired pCT-CBCT images were collected to evaluate the accuracy of DIR and sCT generation. The DIR method was based on a 3D multistage registration network that was trained with 150 paired pCT-CBCT images, and the sCT generation method was performed based on a 2D cycle-consistent adversarial network (CycleGAN) with 6000 paired pCT-CBCT slices for training. Then, the doses were recalculated with the CBCT, pCT, deformed pCT (dpCT) and sCT images by a GPU-based Monte Carlo dose code, ArcherQA, to obtain DoseCBCT, DosepCT, DosedpCT and DosesCT. Organs at risk (OARs) included small intestine, rectum, bladder, spinal cord, femoral heads and bone marrow, CBCT and pCT contours were delineated manually, dpCT contours were propagated through deformation vector fields, sCT contours were auto-segmented and corrected manually. RESULTS: The global gamma pass rate of DosesCT and DosedpCT was 99.66% ± 0.34%, while that of DoseCBCT and DosedpCT was 85.92% ± 7.56% at the 1%/1 mm criterion and a low-dose threshold of 10%. Based on DosedpCT as uniform dose distribution, there were comparable errors in femoral heads and bone marrow for the dpCT and sCT contours compared with CBCT contours, while sCT contours had lower errors in small intestine, rectum, bladder and spinal cord, especially for those with large volume difference of pCT and CBCT. CONCLUSIONS: For cervical cancer radiotherapy, the DIR method and sCT generation could produce similar precise dose distributions, but sCT contours had higher accuracy when the difference in planning CT and CBCT was large.

来源:Radiat Oncol,查看原文。版权归原作者所有。