文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

二维千伏影像在线干预在前列腺癌超分割立体定向放疗中的临床经验与可行性

Clinical Experience and Feasibility of Using 2D-kVimage Online Intervention in the Ultrafractionated Stereotactic Radiation Treatment of Prostate Cancer.
PubMed 文献 · Pract Radiat Oncol · 2022-12-05

本研究纳入15例植入低-中危标记物的前列腺癌患者,采用二维千伏影像在线追踪和2毫米运动阈值手动中断光束策略实施超分割立体定向体部放疗,分析180对千伏摆位图像和1272张束内二维千伏图像,发现前列腺运动随时间推移增加,50/75分次需中断光束,计算三维边界为确保靶区覆盖在侧向、垂直和纵向分别为3.7毫米、4.6毫米和5.0毫米。

要点

  • 前列腺三维平均运动从摆位时1.0毫米增至光束开启时2.0毫米、结束时2.4毫米。
  • 75分次中50分次需光束中断,中断与纵向运动强相关,与垂直方向及治疗起始位置中-弱相关。
  • 以治疗前摆位为参考,束内监测偏差幅度在垂直方向减少0.3毫米、侧向和纵向减少0.4毫米。

核心结论

  • 前列腺运动随时间推移而增加,使用二维千伏在线束内监测系统配合适当干预方案实施前列腺癌超分割立体定向体部放疗是可行的。

研究设计与样本

  • 15例植入低-中危标记物的前列腺癌患者接受超分割立体定向体部放疗,采用在线二维千伏影像追踪和2毫米运动阈值手动光束中断策略。
  • 分析180对千伏摆位图像和1272张束内二维千伏图像,评估摆位偏差和治疗中靶区偏差,采用Spearman检验分析预期治疗中断与图像/治疗时间及偏差方向等参数的相关性。
  • 对22分次数据子集重新评估,比较以计划位置与治疗前摆位位置为参考时分析结果的差异。
  • 根据推导的系统误差和随机误差计算边界,评估工作流程在治疗期间确保前列腺覆盖的可行性。

主要发现

  • 三维平均靶区运动从1.0毫米(摆位0分钟)传播至2.0毫米(光束开启7分钟)至2.4毫米(结束13.5分钟)。
  • 75分次中50分次需要光束中断;中断与前列腺纵向运动强相关,与垂直方向运动及垂直和纵向治疗起始位置中等相关。
  • 以治疗前位置为参考进行束内监测,偏离参考位置的运动偏差幅度在垂直方向减少0.3毫米,在侧向和纵向减少0.4毫米。
  • 确保靶区覆盖的计算三维边界在侧向、垂直、纵向分别为3.7毫米、4.6毫米、5.0毫米。

关键数值与推荐

  • 运动阈值设为2毫米,用于手动光束中断策略。
  • 确保靶区覆盖的三维边界:侧向3.7毫米、垂直4.6毫米、纵向5.0毫米。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study reports clinical experience and feasibility of using a 2-dimensional (2D)-kV image system with online intervention in the ultrafractionated stereotactic body radiation treatment (UF-SBRT) of prostate cancer. METHODS AND MATERIALS: Fifteen patients with prostate cancer who had a low- to intermediate-risk marker implanted received UF-SBRT with online 2D-kV image tracking and a manual beam interruption strategy with a 2-mm motion threshold. A total of 180 kV paired setup images and 1272 intrabeam 2D-kV images were analyzed to evaluate the setup deviation and intratreatment target deviation. Correlation of expected treatment interruptions with a set of parameters (eg, image and treatment time; direction of deviation) was performed (Spearman test). A subset of the data from 22 fractions was re-evaluated to check the differences in analysis results between using the planning position and using the pretreatment setup position as a reference. Margins based on the derived system and random errors were calculated to evaluate the feasibility of the workflow in ensuring prostate coverage during treatment. RESULTS: Mean target motion in 3D propagated from 1.0 mm (setup at 0 minutes) to 2.0 mm (beam on at 7 minutes) to 2.4 mm (end at 13.5 minutes). Out of 75 fractions, 50 were found to require beam interruption. Interruption had a strong correlation with prostate motion along the longitudinal direction and had moderate correlation with prostate motion along the vertical direction and the prostate's treatment starting position along vertical and longitudinal directions. Using the pretreatment position as a reference for intrabeam monitoring, the magnitude of motion deviation from the reference position was reduced by 0.3 mm at a vertical direction and 0.4 mm at lateral and longitudinal directions. The calculated 3D margin to ensure target coverage was 3.7 mm, 4.6 mm, and 5.0 mm in lateral, vertical, and longitudinal directions, respectively. CONCLUSIONS: Prostate motion propagated over time. It is feasible to use a 2D-kV online intrabeam monitoring system with a proper intervention scheme to perform UF-SBRT for prostate cancer.