文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

MR功能成像引导的宫颈癌质子放疗中骨髓保护的剂量学评估

Dosimetric evaluation of bone marrow sparing in proton radiotherapy for cervical cancer guided by MR functional imaging.
PubMed 文献 · Radiat Oncol · 2022-12-14

回顾性纳入33例宫颈癌患者的CT与MR模拟定位图像,基于MRI FatFrac图像勾画盆腔活跃骨髓并分为高活跃与低活跃骨髓,为每例患者设计IMRT、IMRT-BMS、IMPT、IMPT-BMS四种计划并比较剂量学差异。结果显示高活跃骨髓体积占全部活跃骨髓体积的45.2%,四种计划靶区覆盖相似,IMPT-BMS对骨髓保护效果最佳。

要点

  • 高活跃骨髓体积占全部活跃骨髓体积的45.2%。
  • 与IMRT相比,IMRT-BMS、IMPT和IMPT-BMS分别使高活跃骨髓Dmean降低16.6%、14.2%和44.5%(p<0.05)。
  • 与IMRT相比,IMPT-BMS使高活跃骨髓在5-40 Gy各剂量水平的受照体积分别降低10.2%、36.8%、58.8%、67.4%、64.9%和44.5%(p<0.001)。

核心结论

  • MR功能成像技术有助于盆腔活跃骨髓的分级与勾画。
  • MR功能图像引导的宫颈癌质子放疗可实现最佳的骨髓保护。

研究设计与样本

  • 回顾性收集33例宫颈癌患者的CT与MR模拟定位图像。
  • 基于MRI FatFrac图像勾画盆腔骨髓,并根据脂肪含量将其分为高活跃骨髓和低活跃骨髓。
  • 为每例患者设计IMRT、IMRT-BMS、IMPT和IMPT-BMS四种放疗计划,比较四种计划的剂量学差异。

主要发现

  • 入组患者高活跃骨髓体积占全部活跃骨髓体积的45.2%。
  • 四种放疗计划的靶区覆盖相似。
  • 与IMRT的Dmean相比,IMRT-BMS、IMPT和IMPT-BMS分别使高活跃骨髓Dmean降低16.6%、14.2%和44.5%(p<0.05)。
  • IMPT-BMS对骨髓的保护效果最佳。
  • 与IMRT相比,IMPT-BMS使高活跃骨髓在5-40 Gy各剂量水平的受照体积分别降低10.2%、36.8%、58.8%、67.4%、64.9%和44.5%(p<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To segment the pelvic active bone marrow (PABM) using magnetic resonance (MR) functional imaging and investigate the feasibility and dosimetric characteristics of cervical cancer proton radiotherapy for active bone marrow (ABM) sparing. METHODS: We collected CT and MR simulation images of 33 patients with cervical cancer retrospectively. The PBM was contoured on the MRI FatFrac images; the PBM was divided into high-active bone marrow (ABM-high) and low-active bone marrow based on the fat content of the PBM. Four radiotherapy plans were created for each patient, which included intensity-modulated photon therapy (IMRT), bone marrow sparing IMRT (IMRT-BMS), intensity-modulated proton therapy (IMPT), and bone marrow sparing IMPT (IMPT-BMS). The dosimetric differences among the four plans were compared. RESULTS: The ABM-high volume in the enrolled patients accounted for 45.2% of the total ABM volume. The target coverage was similar among the four radiotherapy plans. IMRT-BMS, IMPT, and IMPT-BMS reduced the Dmean of ABM-high by 16.6%, 14.2%, and 44.5%, respectively, compared to the Dmean of IMRT (p < 0.05). IMPT-BMS had the best protective effect on the bone marrow. Compared to IMRT, the volume of ABM-high receiving an irradiation dose of 5-40 Gy decreased by 10.2%, 36.8%, 58.8%, 67.4%, 64.9%, and 44.5%, respectively (p < 0.001). CONCLUSIONS: The MR functional imaging technique helped in the grading and segmentation of PABM. MR functional image-guided proton radiotherapy for cervical cancer can achieve optimal BMS.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Qin X, Gong G, Wang L, et al. Dosimetric evaluation of bone marrow sparing in proton radiotherapy for cervical cancer guided by MR functional imaging. Radiat Oncol. 2022. PMID: 36517839. doi:10.1186/s13014-022-02175-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。