文献速递胸部肿瘤放疗放疗物理与技术

伪孪生网络联合剂量学与临床因素、影像组学特征、CT图像和三维剂量分布预测放射性肺炎的可行性研究

Pseudo-siamese network combined with dosimetric and clinical factors, radiomics features, CT images and 3D dose distribution for the prediction of radiation pneumonitis: A feasibility study.
PubMed 文献 · Clin Transl Radiat Oncol · 2022-11-22

本研究回顾性纳入2016至2020年接受放疗的110例肺癌患者(其中19例发生≥2级放射性肺炎),构建伪孪生网络整合剂量学与临床因素、影像组学特征、CT图像及三维剂量分布预测放射性肺炎。混合模型准确率0.818,敏感度0.800(95%CI [0.299, 0.989]),特异度0.833(95%CI [0.364, 0.991]),5折交叉验证AUC为0.77-0.90(均值±标准差0.85±0.05),结果证实多维特征预测放射性肺炎的可行性。

要点

  • 混合模型预测≥2级放射性肺炎的准确率为0.818。
  • 混合模型敏感度0.800(95%CI [0.299, 0.989]),特异度0.833(95%CI [0.364, 0.991])。
  • 5折交叉验证AUC为0.77-0.90(均值±标准差0.85±0.05)。

核心结论

  • 本研究首次提出结合高维和低维特征预测放射性肺炎的方法,结果证实多维特征预测放射性肺炎的可行性。

研究设计与样本

  • 回顾性纳入2016至2020年接受放疗的110例肺癌患者,其中19例发生≥2级放射性肺炎。
  • 从剂量体积直方图计算肺平均剂量、肺V5和处方剂量等剂量学因素,记录年龄、性别、吸烟状态、TN分期和总分期等临床特征。
  • 提取1419个影像组学特征,采用聚类分析筛选与放射性肺炎相关的特征。
  • 患者随机分为训练集(90%,85例无放射性肺炎和14例放射性肺炎)和验证集(10%,6例无放射性肺炎和5例放射性肺炎)。
  • 设计伪孪生网络架构整合一维(剂量学与临床因素、影像组学)和三维(CT图像、三维剂量分布)特征,采用5折交叉验证评估模型性能。

主要发现

  • 聚类分析共筛选出106个高相关影像组学特征。
  • 输入剂量学与临床因素、剂量分布、CT图像和影像组学特征的准确率分别为0.727、0.636、0.545和0.727。
  • 混合模型准确率为0.818,敏感度为0.800(95%CI [0.299, 0.989]),特异度为0.833(95%CI [0.364, 0.991])。
  • 5折交叉验证的AUC为0.77-0.90,均值±标准差为0.85±0.05。

关键数值与推荐

  • 混合模型预测≥2级放射性肺炎的准确率为0.818。
  • 混合模型敏感度为0.800(95%CI [0.299, 0.989]),特异度为0.833(95%CI [0.364, 0.991])。
  • 5折交叉验证AUC为0.77-0.90(均值±标准差0.85±0.05)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation pneumonitis (RP)(grade ≥ 2) can have a considerable impact on patient quality-of life. In previous studies, the traditional method commonly used radiomics and clinical factors for RP prediction. This study aims to develop and evaluate a novel pseudo-siamese network (PSN) to assist radiologists predict RP before radiotherapy based on combination of dosimetric and clinical factors, radiomics features, CT (computed tomography) images, and dose distribution (hybrid model). METHOD: One hundred and ten patients with lung cancer (19 RP ≥ 2) who received radiotherapy between 2016 and 2020 were retrospectively enrolled in this study. Dosimetric factors were calculated from DVH (dose-volume histogram), such as lung mean dose, lung V5, and prescription dose. Clinical characteristics were recorded, such as age, sex, smoking status, TN stage, and overall stage. A total of 1419 radiomics features were extracted. Cluster analysis was used for detecting radiomics features that associated with RP. Patients were randomly split into a training set (90 %, 85 non-RP, and 14 RP) and a validation set (10 %, 6 non-RP, and 5 RP). A PSN architecture was designed for combining 1D (dosimetric and clinical factors, radiomics) and 3D (CT images, 3D dose distribution) features. 5-fold cross-validation procedure for estimating the skill of the model on new data. RESULTS: For cluster analysis, totally of 106 radiomics features with high correlation were selected. The accuracy was 0.727, 0.636, 0.545, and 0.727 for input dosimetric and clinical factors, dose distribution, CT images, and radiomics features, respectively. The accuracy of hybrid model was 0.818. The sensitivity of hybrid model was 0.800 (95 % confidence interval (CI) [0.299, 0.989]), and specificity was 0.833(95 % CI [0.364, 0.991]). The areas under the receiver operating characteristic curves (AUCs) result in 5-fold cross-validation was 0.77-0.90(mean AUC ± std was 0.85 ± 0.05). CONCLUSION: This study firstly propose method that the combination of high dimensional and low dimensional features for RP prediction. The results confirm the feasibility of multi-dimensional features predict RP.

来源:Clin Transl Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Feng B, Zhou W, Yang X, et al. Pseudo-siamese network combined with dosimetric and clinical factors, radiomics features, CT images and 3D dose distribution for the prediction of radiation pneumonitis: A feasibility study. Clin Transl Radiat Oncol. 2022. PMID: 36479235. doi:10.1016/j.ctro.2022.11.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。