文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

深度学习在宫颈癌CT图像分割中的应用:系统综述与Meta分析

Deep learning in CT image segmentation of cervical cancer: a systematic review and meta-analysis.
PubMed 文献 · Radiat Oncol · 2022-11-07

该系统综述与Meta分析检索了PubMed、Embase、Cochrane图书馆和Web of Science,纳入14篇关于深度学习用于宫颈癌CT图像分割的研究,对分割结果的Dice相似系数(DSC)进行Meta分析。结果显示临床靶区(CTV)、膀胱、直肠、股骨头的合并DSC分别为0.86(95%CI 0.84至0.87)、0.91(95%CI 0.89至0.93)、0.83(95%CI 0.79至0.88)、0.92(95%CI 0.91至0.94)。作者认为深度学习自动分割准确性较好且耗时较少,但仍需公共高质量数据库和大规模研究验证。

要点

  • 临床靶区(CTV)的合并DSC为0.86(95%CI 0.84至0.87)。
  • 膀胱、直肠、股骨头的合并DSC分别为0.91、0.83、0.92。
  • 样本量分组(大于100与小于100,或大于150与小于150)对分割性能无差异(P>0.05)。

核心结论

  • 深度学习在宫颈癌CT图像自动分割中准确性较好且耗时较少,在未来的放射治疗应用中有良好前景,但仍需公共高质量数据库和大规模研究验证。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Embase、Cochrane图书馆和Web of Science,最终纳入14篇文章进行Meta分析,研究方案已在PROSPERO注册(CRD42022307071)。

主要发现

  • 临床靶区(CTV)的合并DSC为0.86(95%CI 0.84至0.87)。
  • 膀胱的合并DSC为0.91(95%CI 0.89至0.93)。
  • 直肠的合并DSC为0.83(95%CI 0.79至0.88)。
  • 股骨头的合并DSC为0.92(95%CI 0.91至0.94)。
  • 按样本量分组(大于100与小于100,或大于150与小于150)比较,分割性能均无差异(P>0.05);4篇文章报告分割时间为15秒至2分钟。

关键数值与推荐

  • 2D模型分割CTV的DSC为0.87(95%CI 0.85至0.90),3D模型分割CTV的DSC为0.85(95%CI 0.82至0.87)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 仍需公共高质量数据库和大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This paper attempts to conduct a systematic review and meta-analysis of deep learning (DLs) models for cervical cancer CT image segmentation. METHODS: Relevant studies were systematically searched in PubMed, Embase, The Cochrane Library, and Web of science. The literature on DLs for cervical cancer CT image segmentation were included, a meta-analysis was performed on the dice similarity coefficient (DSC) of the segmentation results of the included DLs models. We also did subgroup analyses according to the size of the sample, type of segmentation (i.e., two dimensions and three dimensions), and three organs at risk (i.e., bladder, rectum, and femur). This study was registered in PROSPERO prior to initiation (CRD42022307071). RESULTS: A total of 1893 articles were retrieved and 14 articles were included in the meta-analysis. The pooled effect of DSC score of clinical target volume (CTV), bladder, rectum, femoral head were 0.86(95%CI 0.84 to 0.87), 0.91(95%CI 0.89 to 0.93), 0.83(95%CI 0.79 to 0.88), and 0.92(95%CI 0.91to 0.94), respectively. For the performance of segmented CTV by two dimensions (2D) and three dimensions (3D) model, the DSC score value for 2D model was 0.87 (95%CI 0.85 to 0.90), while the DSC score for 3D model was 0.85 (95%CI 0.82 to 0.87). As for the effect of the capacity of sample on segmentation performance, no matter whether the sample size is divided into two groups: greater than 100 and less than 100, or greater than 150 and less than 150, the results show no difference (P > 0.05). Four papers reported the time for segmentation from 15 s to 2 min. CONCLUSION: DLs have good accuracy in automatic segmentation of CT images of cervical cancer with a less time consuming and have good prospects for future radiotherapy applications, but still need public high-quality databases and large-scale research verification.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Yang C, Qin LH, Xie YE, et al. Deep learning in CT image segmentation of cervical cancer: a systematic review and meta-analysis. Radiat Oncol. 2022. PMID: 36344989. doi:10.1186/s13014-022-02148-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。