直肠癌放疗患者等中心位移及计划靶区边界的影响因素
本研究回顾性收集189例直肠癌放疗患者的平移和角度等中心位移,计算随机与系统误差并推导计划靶区(PTV)边界,分析体位、体重指数(BMI)和固定装置的影响。在线校正前系统误差在头脚、左右、前后方向分别为2.5、2.8、3.0 mm,随机误差分别为6.2、7.4、8.2 mm;推荐每日图像引导放疗(IGRT)PTV边界0.7 cm,非每日IGRT为1.0 cm。俯卧位和BMI>30 kg/m2在非每日IGRT时需更大边界,分别为1.2和1.4 cm。
要点
- 在线校正前系统误差头脚2.5 mm、左右2.8 mm、前后3.0 mm,随机误差分别为6.2、7.4、8.2 mm。
- 推荐PTV边界每日IGRT为0.7 cm,非每日IGRT为1.0 cm。
- 俯卧位和BMI>30 kg/m2在非每日IGRT时需更大边界,分别为1.2和1.4 cm。
核心结论
- 俯卧位、BMI>30 kg/m2和腹板装置与更大的每日摆位误差相关,在非每日IGRT时需要更大的PTV边界,但使用每日IGRT可避免。
研究设计与样本
- 回顾性收集189例直肠癌放疗患者的平移和角度等中心位移,计算随机与系统误差并推导PTV边界。
- 研究体位、BMI和固定装置类型的影响。
- 使用在线校正前后的门静脉图像分别定义非每日IGRT和每日IGRT的PTV。
主要发现
- 在线校正前系统误差头脚(SI)2.5 mm、左右(RL)2.8 mm、前后(AP)3.0 mm,校正后分别为2.1、1.7、1.8 mm。
- 在线校正前随机误差SI 6.2 mm、RL 7.4 mm、AP 8.2 mm,校正后分别为4、4.2、4.5 mm。
- 推荐PTV边界每日IGRT为0.7 cm,非每日IGRT为1.0 cm。
- 俯卧位和BMI>30 kg/m2在非每日IGRT时需更大边界,分别为1.2和1.4 cm。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Setup errors are inherent in the process of daily radiation therapy (RT) delivery. Pelvic RT for rectal cancer is one of the body sites associated with the largest shift among other body sites. This study aimed to evaluate interfraction random and systematic errors and hence propose the optimum planning target volume (PTV) in patients with rectal cancer. METHODS AND MATERIALS: Translational and angular isocenter displacements were retrospectively collected for 189 patients. Random and systematic errors were determined, and then the PTV margin was computed. Effect of positioning, body mass index (BMI), and type of immobilization were studied. Portal images before and after online correction were used to define PTV for no-daily image-guided radiotherapy (IGRT) and daily IGRT respectively. RESULTS: Before the online correction, the systematic errors were 2.5, 2.8, and 3.0 mm for superior-inferior (SI), right-left (RL), and anterior-posterior (AP) directions, respectively, compared with 2.1, 1.7, and 1.8 mm after online correction. The random errors were 6.2, 7.4, and 8.2 mm in SI, RL, and AP, respectively, before online correction, compared with 4, 4.2, and 4.5 mm after online correction. The recommended PTV margin was 0.7 and 1.0 cm for daily IGRT and no-daily IGRT, respectively. The prone position and BMI >30 kg/m2 warrant higher margins in no-daily IGRT cases, 1.2 and 1.4 cm, respectively. CONCLUSIONS: The prone position, BMI >30 kg/m2, and belly board device are associated with larger daily setup errors warranting higher PTV margins for no-daily IGRT; however, that can be avoided by using daily IGRT.
引用
- Mohamed R, Elawadi AA, Alkhanein N, et al. Factors Affecting Isocenter Displacement and Planning Target Volume Margin for Patients With Rectal Cancer Receiving Radiation Therapy. Adv Radiat Oncol. 2022. PMID: 36420207. doi:10.1016/j.adro.2022.101060