文献速递消化道肿瘤放疗放疗物理与技术

多解剖场景在胰腺癌碳离子放疗计划优化中的作用

The role of multiple anatomical scenarios in plan optimization for carbon ion radiotherapy of pancreatic cancer.
PubMed 文献 · Radiother Oncol · 2022-09-14

本研究对10例既往接受新辅助碳离子放疗的胰腺癌患者,在放疗开始前后多个时间点采集4DCT,比较三种稳健优化策略。结果显示包含RE1-0Ex可患者特异性改善分次间稳健性但平均不显著,半数计划需至少一次再优化,放疗前十二指肠轮廓对后续位置预测能力有限,提示快速在线自适应对保证治疗质量至关重要。

要点

  • 10例胰腺癌患者4DCT采集于放疗开始前约15、5、1天及后6天,处方38.4 Gy(RBE)分8次。
  • 策略A下无重新计算超过胃肠道危及器官D1%约束38 Gy(RBE)。
  • 纳入RE1-0Ex改善患者特异性分次间稳健性,但平均无显著差异。

核心结论

  • 多个再评估时间点显示的解剖变化证明,快速高效的在线自适应对优化胰腺癌碳离子放疗质量至关重要。

研究设计与样本

  • 对10例既往接受新辅助碳离子放疗的胰腺癌患者,在放疗开始前约15天(CTPlan)、前5天(RE1)、前1天(RE2)及后6天(RE3)采集4DCT。
  • 计划重新优化至处方38.4 Gy(RBE)分8次,约束为胃肠道危及器官体积1%的剂量D1%不超过38 Gy(RBE)。
  • 测试三种策略:A为基于CTPlan最大呼气相(0Ex)的稳健优化,含3 mm摆位误差、3%射程不确定度并包括30%吸气相;B为在优化问题中加入RE1-0Ex场景;C为在每个REi重新计算计划并根据临床目标偏差阈值进行自适应(RPi)。

主要发现

  • 策略A下无重新计算超过D1%约束。
  • 策略B中纳入RE1-0Ex在患者特异性基础上改善分次间稳健性,但平均无显著差异。
  • 策略C中半数计划将至少一次被重新优化以恢复靶区覆盖和/或最小化十二指肠剂量。
  • 放疗前十二指肠轮廓与后续轮廓相交时差异显著,无论是否外扩。

关键数值与推荐

  • 处方剂量38.4 Gy(RBE)分8次,胃肠道危及器官D1%约束38 Gy(RBE)。
  • 稳健优化参数:摆位误差3 mm,射程不确定度3%,包括30%吸气相。
  • 自适应触发依据与临床目标的偏差阈值。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE /OBJECTIVE: To quantify benefits of robust optimization on multiple 4DCT acquisitions combined with off-line treatment adaptation for neoadjuvant carbon ion therapy (CIRT) of pancreatic cancer. MATERIAL/METHODS: For 10 previously treated patients, 4DCTs were acquired around -15 (CTPlan), -5 (RE1), -1 (RE2) and +6 (RE3) days from RT start. Treatment plans were newly optimized to a dose prescription of 38.4 Gy(RBE) (8 fractions) with a constraint of 38 Gy(RBE) to 1% of the gastrointestinal organs at risk volume (D1%). Three strategies were tested: (A) robust optimization on CTPlan maximum exhale (0Ex) with 3 mm set-up, 3% range uncertainty, including 30%-inhale; (B) addition of the RE1-0Ex scenario; (C) plan recalculation at each REi and adaptation (RPi) according to deviation thresholds from clinical goals. The cumulative variation of target coverage and GI-OARs doses was evaluated. Duodenum contours of all 4DCTs of each patient were registered on CTPlan-0Ex. The capacity of pre-RT acquisitions to predict duodenum position was investigated by computing the intersection of contours at CTplan, RE1, or their union, with respect to subsequent 4DCTs and the CTV, coupled with increasing margin. RESULTS: (A) No recalculation exceeded the D1% constraint. (B) The inclusion of RE1-0Ex in the optimization problem improved inter-fraction robustness on a patient-specific basis, but was non-significant on average. (C) Half of the plans would be re-optimized to recover target coverage and/or minimize duodenum dose, at least once. A significant difference was observed between pre-RT duodenum contours when intersecting subsequent contours, either with a margin expansion. CONCLUSION: Anatomical variations highlighted at multiple REi proved that a fast and efficient online adaptation is essential to optimize treatment quality of CIRT for pancreatic cancer.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Molinelli S, Vai A, Russo S, et al. The role of multiple anatomical scenarios in plan optimization for carbon ion radiotherapy of pancreatic cancer. Radiother Oncol. 2022. PMID: 36113776. doi:10.1016/j.radonc.2022.09.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。