文献速递头颈部肿瘤放疗放疗物理与技术

头颈部肿瘤调强质子治疗中基于在线自适应计划库的方法

An online adaptive plan library approach for intensity modulated proton therapy for head and neck cancer.
PubMed 文献 · Radiother Oncol · 2022-09-20

本研究针对15例头颈部肿瘤患者,提出并评估基于患者特异性治疗前计划库(PL)的每日计划选择策略,并与固定鲁棒性设置(fSR3)及触发式离线自适应方案(fSR3OfA)比较。结果显示PL策略总体降低口干和吞咽困难的风险(NTCP),目标覆盖略有代价;对部分患者fSR3OfA覆盖更优。

要点

  • PL策略较fSR3和fSR3OfA总体降低口干≥II级&III级及吞咽困难≥III级风险。
  • 6/15例患者经PL策略口干和/或吞咽困难≥II级风险可降低>2%。
  • PL策略以有限的目标覆盖代价换取NTCP降低;部分患者fSR3OfA覆盖更优。

核心结论

  • 所提出的计划库(PL)策略较fSR3和fSR3OfA总体降低NTCP,但目标覆盖有一定代价。

研究设计与样本

  • 针对15例头颈部肿瘤患者,利用计划CT生成含5个计划的计划库(PL),分别稳健优化SR为0、1、2、3、5 mm并加3%距离鲁棒性。
  • 使用重复CT(rCT)及真实摆位和距离不确定度分布模拟PL、固定SR(fSR3)及触发式离线自适应方案(fSR3OfA)的治疗过程。
  • PL策略的每日计划选择仅基于rCT上重新计算的CTV剂量。

主要发现

  • 与fSR3和fSR3OfA相比,PL策略组口干≥II级&III级及吞咽困难≥III级风险显著降低。
  • 6/15例患者使用PL策略后口干和/或吞咽困难≥II级风险可降低>2%。
  • 其余患者中,PL策略对目标覆盖约束的依从性常得到改善。
  • 对部分患者,fSR3OfA较PL显著改善覆盖。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: In intensity modulated proton therapy (IMPT), the impact of setup errors and anatomical changes is commonly mitigated by robust optimization with population-based setup robustness (SR) settings and offline replanning. In this study we propose and evaluate an alternative approach based on daily plan selection from patient-specific pre-treatment established plan libraries (PLs). Clinical implementation of the PL strategy would be rather straightforward compared to daily online re-planning. MATERIALS AND METHODS: For 15 head-and-neck cancer patients, the planning CT was used to generate a PL with 5 plans, robustly optimized for increasing SR: 0, 1, 2, 3, 5 mm, and 3% range robustness. Repeat CTs (rCTs) and realistic setup and range uncertainty distributions were used for simulation of treatment courses for the PL approach, treatments with fixed SR (fSR3) and a trigger-based offline adaptive schedule for 3 mm SR (fSR3OfA). Daily plan selection in the PL approach was based only on recomputed dose to the CTV on the rCT. RESULTS: Compared to using fSR3 and fSR3OfA, the risk of xerostomia grade ≥ II & III and dysphagia ≥ grade III were significantly reduced with the PL. For 6/15 patients the risk of xerostomia and/or dysphagia ≥ grade II could be reduced by > 2% by using PL. For the other patients, adherence to target coverage constraints was often improved. fSR3OfA resulted in significantly improved coverage compared to PL for selected patients. CONCLUSION: The proposed PL approach resulted in overall reduced NTCPs compared to fSR3 and fSR3OfA at limited cost in target coverage.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Oud M, Breedveld S, Giżyńska M, et al. An online adaptive plan library approach for intensity modulated proton therapy for head and neck cancer. Radiother Oncol. 2022. PMID: 36150418. doi:10.1016/j.radonc.2022.09.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。