文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

一种基于知识的新型预测模型用于在宫颈癌半自动计划中估算初始等效均匀剂量

A novel knowledge-based prediction model for estimating an initial equivalent uniform dose in semi-auto-planning for cervical cancer.
PubMed 文献 · Radiat Oncol · 2022-08-29

研究提出等效均匀长度(EUL)概念,基于60例宫颈癌IMRT计划建立直肠和膀胱的EUD-EUL知识库预测模型(线性回归,R²分别为0.69和0.79),并在20例样本中比较EE计划、PAP计划与人工计划。EE计划膀胱V40、V50显著低于人工计划,膀胱V30和Dmean显著低于PAP计划。

要点

  • EUL与EUD线性回归相关:膀胱R²=0.79,直肠R²=0.69。
  • EE计划膀胱V40 30.00±5.76、V50 14.36±4.00,显著低于人工计划V40 36.03±8.02、V50 19.02±5.42。
  • EE计划膀胱V30 50.55±6.33、Dmean 31.48±1.97 Gy,显著低于PAP计划。

核心结论

  • EEKB预测模型基于患者特异性几何EUL值预测直肠和膀胱的合理初始EUD值,从而改善优化和计划效率。

研究设计与样本

  • 从60例宫颈癌患者的IMRT计划中提取直肠和膀胱的EUL指标,采用线性回归分别建立EULr-EUDr和EULb-EUDb两个EEKB预测模型。
  • 将预测的直肠和膀胱初始EUD参数与其他器官的常规Pinnacle自动计划(PAP)初始剂量参数结合优化EE计划,并在20例患者样本中比较EE计划、PAP计划(基于默认PAP初始参数)和人工计划(由不同剂量师手动设计)的一致性和质量。

主要发现

  • 线性回归分析显示EUL与EUD显著相关(膀胱EU Db R²=0.79,直肠EUDr R²=0.69)。
  • 20例样本中,EE计划膀胱平均V40(30.00±5.76)和V50(14.36±4.00)显著低于人工计划(V40:36.03±8.02,V50:19.02±5.42)。
  • 与PAP计划相比,EE计划膀胱平均V30(50.55±6.33)和Dmean(31.48±1.97 Gy)显著更低。

关键数值与推荐

  • 膀胱EUL与EUD线性回归R²=0.79,直肠EUL与EUD线性回归R²=0.69。
  • EE计划膀胱V40 30.00±5.76 vs 人工计划36.03±8.02;EE计划膀胱V50 14.36±4.00 vs 人工计划19.02±5.42。
  • EE计划膀胱V30 50.55±6.33、Dmean 31.48±1.97 Gy,显著低于PAP计划。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We developed a novel concept, equivalent uniform length (EUL), to describe the relationship between the generalized equivalent uniform dose (EUD) and the geometric anatomy around a tumor target. By correlating EUL with EUD, we established two EUD-EUL knowledge-based (EEKB) prediction models for the bladder and rectum that predict initial EUD values for generating quality treatment plans. METHODS: EUL metrics for the rectum and bladder were extracted and collected from the intensity-modulated radiotherapy therapy (IMRT) plans of 60 patients with cervical cancer. The two EEKB prediction models were built using linear regression to establish the relationships between EULr and EUDr (EUL and EUD of rectum) and EULb, and EUDb (EUL and EUD of bladder), respectively. The EE plans were optimized by incorporating the predicted initial EUD parameters for the rectum and bladder with the conventional pinnacle auto-planning (PAP) initial dose parameters for other organs. The efficiency of the predicted initial EUD values were then evaluated by comparing the consistency and quality of the EE plans, PAP plans (based on default PAP initial parameters), and manual plans (designed manually by different dosimetrists) for a sample of 20 patients. RESULTS: Linear regression analyses showed a significant correlation between EUL and EUD (R2 = 0.79 and 0.69 for EUDb and EUDr, respectively). In a sample of 20 patients, the average bladder V40 and V50 derived from the EE plans were significantly lower (V40: 30.00 ± 5.76, V50: 14.36 ± 4.00) than the V40 and V50 values derived from manual plans (V40: 36.03 ± 8.02, V50: 19.02 ± 5.42). Compared with the PAP plans, the EE plans produced significantly lower average V30 and Dmean values for the bladder (V30: 50.55 ± 6.33, Dmean: 31.48 ± 1.97 Gy). CONCLUSIONS: Our EEKB prediction models predicted reasonable initial EUD values for the rectum and bladder based on patient-specific geometric EUL values, thereby improving optimization and planning efficiency.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Tao C, Liu B, Li C, et al. A novel knowledge-based prediction model for estimating an initial equivalent uniform dose in semi-auto-planning for cervical cancer. Radiat Oncol. 2022. PMID: 36038941. doi:10.1186/s13014-022-02120-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。