全肺影像组学与剂量组学特征可预测放射性肺炎:一项含前瞻性外部验证与决策曲线分析的模型开发研究
研究在314例回顾性收集和35例前瞻性入组的肺癌患者中提取影像组学、剂量组学、剂量体积直方图指标及临床参数,构建6个模型预测放射性肺炎。整合影像组学风险评分、剂量组学风险评分与临床参数的模型区分度最佳,训练集、自助重采样集和外部测试集的曲线下面积分别为0.793、0.774和0.855。校准曲线显示预测值与实际值一致性良好,决策曲线显示基于列线图的最终模型具有正向净获益。
要点
- 整合影像组学评分、剂量组学评分与临床参数的模型在外部测试集曲线下面积为0.855(95%CI 0.719-0.990)。
- 最佳模型校准曲线斜率为1.21、截距为-0.04,预测值与实际值一致性良好。
- 基于列线图的最终模型决策曲线显示正向净获益。
核心结论
- 影像组学和剂量组学特征有潜力辅助预测放射性肺炎,影像组学、剂量组学与临床参数联合在本研究中得到最佳预后模型。
研究设计与样本
- 研究纳入2013年至2019年间314例回顾性收集和35例前瞻性入组的肺癌患者,提取影像组学、剂量组学、剂量体积直方图指标及临床参数。
- 经特征选择后基于逻辑回归计算影像组学风险评分、剂量组学风险评分及剂量体积直方图评分,并用不同组合构建6个模型评估其附加预后价值。
- 采用训练集自助重采样评估过度乐观,前瞻性收集队列作为外部测试集,评估最佳模型的校准与决策曲线特征,并为所选模型构建列线图。
主要发现
- 整合影像组学风险评分、剂量组学风险评分与临床参数的模型区分度最佳,训练集曲线下面积为0.793(95%CI 0.735-0.851)。
- 同一最佳模型的自助重采样集曲线下面积为0.774(95%CI 0.762-0.786),外部测试集曲线下面积为0.855(95%CI 0.719-0.990)。
- 校准曲线显示预测值与实际值一致性良好,斜率为1.21、截距为-0.04;决策曲线显示基于列线图的最终模型具有正向净获益。
关键数值与推荐
- 最佳模型在训练集、自助重采样集和外部测试集的曲线下面积分别为0.793(95%CI 0.735-0.851)、0.774(95%CI 0.762-0.786)和0.855(95%CI 0.719-0.990)。
- 最佳模型校准曲线斜率为1.21、截距为-0.04。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Radiation pneumonitis (RP) is one of the common side effects of radiation therapy in the thoracic region. Radiomics and dosiomics quantify information implicit within medical images and radiation therapy dose distributions. In this study we demonstrate the prognostic potential of radiomics, dosiomics, and clinical features for RP prediction. METHODS AND MATERIALS: Radiomics, dosiomics, dose-volume histogram (DVH) metrics, and clinical parameters were obtained on 314 retrospectively collected and 35 prospectively enrolled patients diagnosed with lung cancer between 2013 to 2019. A radiomics risk score (R score) and dosiomics risk score (D score), as well as a DVH-score, were calculated based on logistic regression after feature selection. Six models were built using different combinations of R score, D score, DVH score, and clinical parameters to evaluate their added prognostic power. Overoptimism was evaluated by bootstrap resampling from the training set, and the prospectively collected cohort was used as the external test set. Model calibration and decision-curve characteristics of the best-performing models were evaluated. For ease of further evaluation, nomograms were constructed for selected models. RESULTS: A model built by integrating all of the R score, D score, and clinical parameters had the best discriminative ability with areas under the curve of 0.793 (95% confidence interval [CI], 0.735-0.851), 0.774 (95% CI, 0.762-0.786), and 0.855 (95% CI, 0.719-0.990) in the training, bootstrapping, and external test sets, respectively. The calibration curve image showed good agreement between the predicted and actual values, with a slope of 1.21 and intercept of -0.04. The decision curve image showed a positive net benefit for the final model based on the nomogram. CONCLUSIONS: Radiomic and dosiomic features have the potential to assist with the prediction of RP, and the combination of radiomics, dosiomics, and clinical parameters led to the best prognostic model in the present study.
引用
- Zhang Z, Wang Z, Yan M, et al. Radiomics and Dosiomics Signature From Whole Lung Predicts Radiation Pneumonitis: A Model Development Study With Prospective External Validation and Decision-curve Analysis. Int J Radiat Oncol Biol Phys. 2022. PMID: 36031028. doi:10.1016/j.ijrobp.2022.08.047
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。