文献速递头颈部肿瘤放疗放疗物理与技术

头颈癌患者MRI上肿瘤体积勾画的 delineation 不确定性

Delineation uncertainties of tumour volumes on MRI of head and neck cancer patients.
PubMed 文献 · Clin Transl Radiat Oncol · 2022-08-06

研究纳入两个独立科室的32例头颈癌患者,由丹麦4名临床肿瘤学家和澳大利亚4名放射肿瘤学家在T2加权MRI上独立勾画原发肿瘤GTV(GTV-T)和淋巴结GTV(GTV-N),使用STAPLE参考体积评估观察者间变异。结果显示GTV-T和GTV-N的中位MASD分别为0.17 cm和0.07 cm,中位DSC分别为0.73和0.76,中位DSC与中位体积显著相关。结论认为中位IOV低于2 mm,但部分区域难以区分恶性肿瘤与水肿,可能通过进一步培训改善。

要点

  • 头颈癌MRI勾画GTV-T和GTV-N的中位MASD分别为0.17 cm和0.07 cm。
  • GTV-T和GTV-N相对STAPLE体积的中位DSC分别为0.73和0.76。
  • 中位DSC与GTV-T体积(Spearman相关系数0.76,p<0.001)及GTV-N体积(Spearman相关系数0.55,p<0.001)显著相关。

核心结论

  • 头颈癌患者MRI上勾画GTV-T和GTV-N的中位观察者间变异低于2 mm。
  • 肿瘤中部分特定区域难以分辨为恶性组织或水肿,可能通过进一步MR-only勾画培训改善。

研究设计与样本

  • 来自两个独立科室的32例头颈癌患者纳入研究。
  • 丹麦4名临床肿瘤学家和澳大利亚4名放射肿瘤学家在治疗计划时的T2加权MR图像上独立勾画原发肿瘤GTV(GTV-T)和淋巴结GTV(GTV-N)。
  • 观察者获得图像集、勾画指南和患者简介。
  • 使用所有观察者轮廓为每个结构生成同时真实与性能水平估计(STAPLE)参考体积。

主要发现

  • 每名观察者勾画了32个GTV-T和68个GTV-N。
  • 所有患者GTV-T和GTV-N的中位MASD分别为0.17 cm(范围0.08-0.39 cm)和0.07 cm(范围0.04-0.33 cm)。
  • 所有患者GTV-T和GTV-N相对STAPLE体积的中位DSC分别为0.73和0.76。
  • 中位DSC与GTV-T中位体积之间(Spearman相关系数0.76,p<0.001)及与GTV-N中位体积之间(Spearman相关系数0.55,p<0.001)见显著相关。

关键数值与推荐

  • GTV-T中位MASD为0.17 cm(范围0.08-0.39 cm),GTV-N中位MASD为0.07 cm(范围0.04-0.33 cm)。
  • GTV-T中位DSC为0.73,GTV-N中位DSC为0.76。
  • GTV-T中位DSC与中位体积的Spearman相关系数为0.76(p<0.001),GTV-N为0.55(p<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: During the last decade, radiotherapy using MR Linac has gone from research to clinical implementation for different cancer locations. For head and neck cancer (HNC), target delineation based only on MR images is not yet standard, and the utilisation of MRI instead of PET/CT in radiotherapy planning is not well established. We aimed to analyse the inter-observer variation (IOV) in delineating GTV (gross tumour volume) on MR images only for patients with HNC. MATERIAL/METHODS: 32 HNC patients from two independent departments were included. Four clinical oncologists from Denmark and four radiation oncologists from Australia had independently contoured primary tumour GTVs (GTV-T) and nodal GTVs (GTV-N) on T2-weighted MR images obtained at the time of treatment planning. Observers were provided with sets of images, delineation guidelines and patient synopsis. Simultaneous truth and performance level estimation (STAPLE) reference volumes were generated for each structure using all observer contours. The IOV was assessed using the DICE Similarity Coefficient (DSC) and mean absolute surface distance (MASD). RESULTS: 32 GTV-Ts and 68 GTV-Ns were contoured per observer. The median MASD for GTV-Ts and GTV-Ns across all patients was 0.17 cm (range 0.08-0.39 cm) and 0.07 cm (range 0.04-0.33 cm), respectively. Median DSC relative to a STAPLE volume for GTV-Ts and GTV-Ns across all patients were 0.73 and 0.76, respectively. A significant correlation was seen between median DSCs and median volumes of GTV-Ts (Spearman correlation coefficient 0.76, p < 0.001) and of GTV-Ns (Spearman correlation coefficient 0.55, p < 0.001). CONCLUSION: Contouring GTVs in patients with HNC on MRI showed that the median IOV for GTV-T and GTV-N was below 2 mm, based on observes from two separate radiation departments. However, there are still specific regions in tumours that are difficult to resolve as either malignant tissue or oedema that potentially could be improved by further training in MR-only delineation.

来源:Clin Transl Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Zukauskaite R, Rumley CN, Hansen CR, et al. Delineation uncertainties of tumour volumes on MRI of head and neck cancer patients. Clin Transl Radiat Oncol. 2022. PMID: 36017132. doi:10.1016/j.ctro.2022.08.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。