基于深度卷积神经网络生成合成增强CT用于乳腺癌放疗中心脏亚结构勾画的可行性研究

Synthetic contrast-enhanced computed tomography generation using a deep convolutional neural network for cardiac substructure delineation in breast cancer radiation therapy: a feasibility study.
PubMed 文献 · Radiat Oncol · 2022-04-22

本研究利用条件生成对抗网络从59例患者的平扫CT生成合成增强CT,其中35对用于训练、4对用于验证、20对用于测试。合成增强CT与增强CT在图像相似性、心脏亚结构勾画几何一致性及剂量学分析中均显示出可行性,平均心脏剂量和V5Gy的误差率分别为0.13±0.27 Gy和0.71±1.34%。

要点

  • 合成增强CT与增强CT的平均绝对误差为20.66±5.29,峰值信噪比为21.57±1.85,结构相似性指数为0.77±0.06。
  • 合成增强CT与增强CT轮廓的Dice相似系数为0.81±0.06,平均表面距离为2.44±0.72。
  • 剂量学分析显示平均心脏剂量误差率为0.13±0.27 Gy,V5Gy误差率为0.71±1.34%。

核心结论

  • 研究结果表明从平扫CT生成合成增强CT具有可行性,并显示出在乳腺癌放疗患者心脏亚结构勾画中的潜在应用价值。

研究设计与样本

  • 本研究为可行性研究,采用条件生成对抗网络框架生成合成增强CT。
  • 共准备59例患者的平扫CT与增强CT心脏扫描配对,其中35对用于训练、4对用于验证、20对用于测试。
  • 验证分三阶段:评估合成增强CT与增强CT的相似性;在合成增强CT与增强CT上间隔足够时间进行手动勾画并测量心脏亚结构的几何相似性;基于合成增强CT与增强CT的轮廓对治疗计划进行定量分析。

主要发现

  • 合成增强CT与增强CT的平均绝对误差为20.66±5.29,峰值信噪比为21.57±1.85,结构相似性指数为0.77±0.06。
  • 平扫CT与增强CT的平均绝对误差为23.95±6.98,峰值信噪比为20.67±2.34,结构相似性指数为0.76±0.07。
  • 合成增强CT与增强CT轮廓的Dice相似系数为0.81±0.06,平均表面距离为2.44±0.72。
  • 剂量学分析显示平均心脏剂量误差率为0.13±0.27 Gy,V5Gy误差率为0.71±1.34%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Adjuvant radiation therapy improves the overall survival and loco-regional control in patients with breast cancer. However, radiation-induced heart disease, which occurs after treatment from incidental radiation exposure to the cardiac organ, is an emerging challenge. This study aimed to generate synthetic contrast-enhanced computed tomography (SCECT) from non-contrast CT (NCT) using deep learning (DL) and investigate its role in contouring cardiac substructures. We also aimed to determine its applicability for a retrospective study on the substructure volume-dose relationship for predicting radiation-induced heart disease. METHODS: We prepared NCT-CECT cardiac scan pairs of 59 patients. Of these, 35, 4, and 20 pairs were used for training, validation, and testing, respectively. We adopted conditional generative adversarial network as a framework to generate SCECT. SCECT was validated in the following three stages: (1) The similarity between SCECT and CECT was evaluated; (2) Manual contouring was performed on SCECT and CECT with sufficient intervals and based on this, the geometric similarity of cardiac substructures was measured between them; (3) The treatment plan was quantitatively analyzed based on the contours of SCECT and CECT. RESULTS: While the mean values (± standard deviation) of the mean absolute error, peak signal-to-noise ratio, and structural similarity index measure between SCECT and CECT were 20.66 ± 5.29, 21.57 ± 1.85, and 0.77 ± 0.06, those were 23.95 ± 6.98, 20.67 ± 2.34, and 0.76 ± 0.07 between NCT and CECT, respectively. The Dice similarity coefficients and mean surface distance between the contours of SCECT and CECT were 0.81 ± 0.06 and 2.44 ± 0.72, respectively. The dosimetry analysis displayed error rates of 0.13 ± 0.27 Gy and 0.71 ± 1.34% for the mean heart dose and V5Gy, respectively. CONCLUSION: Our findings displayed the feasibility of SCECT generation from NCT and its potential for cardiac substructure delineation in patients who underwent breast radiation therapy.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Chun J, Chang JS, Oh C, et al. Synthetic contrast-enhanced computed tomography generation using a deep convolutional neural network for cardiac substructure delineation in breast cancer radiation therapy: a feasibility study. Radiat Oncol. 2022. PMID: 35459221. doi:10.1186/s13014-022-02051-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。