文献速递乳腺癌放疗放疗物理与技术

乳腺癌放疗靶区分割深度学习模型的临床评估

Clinical evaluation of a deep learning model for segmentation of target volumes in breast cancer radiotherapy.
PubMed 文献 · Radiother Oncol · 2022-04-18

研究在150例乳腺癌患者计划CT上按国际指南由专家勾画CTV,构建并验证3D卷积神经网络,并在20例测试集中评估。结果显示CNN分割在指南一致性上优于人工(90.71% vs 77.14%),每例平均节省24分钟,但对淋巴结PTV存在显著欠分割。

要点

  • 3D CNN对乳腺癌CTV分割可行且性能良好,指南一致性从77.14%提升至90.71%。
  • CNN分割每例平均节省24分钟,纯人工分割中位时间为35分钟。
  • 对淋巴结PTV存在显著欠分割,对原发灶PTV过分割未达统计学显著。

核心结论

  • 基于3D CNN的乳腺癌放疗勾画是可行且性能良好的,依据定量和定性指标评分。

研究设计与样本

  • 由一名专家放射肿瘤医师按国际指南对150例乳腺癌患者分别勾画所有CTV,用于创建、训练和验证3D CNN。
  • 网络性能另在20例患者的测试集中评估。
  • 主要终点为对CNN生成的各层面及总PTV分割数据进行定量和定性分析,次要终点为时间效率评估。

主要发现

  • 测试集中分割性能对侧乳腺和乳腺CTV最好,对Rotter间隙和内乳淋巴结区最差。
  • 对PTV的影响分析显示原发灶PTV过分割未达统计学显著,淋巴结PTV欠分割有统计学显著,导致与OAR重叠轻微变化。
  • 指南一致性从77.14%提升至90.71%,有利于CNN分割,同时每例平均节省24分钟,纯人工分割中位时间为35分钟。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE/OBJECTIVE(S): Precise segmentation of clinical target volumes (CTV) in breast cancer is indispensable for state-of-the art radiotherapy. Despite international guidelines, significant intra- and interobserver variability exists, negatively impacting treatment outcomes. The aim of this study is to evaluate the performance and efficiency of segmentation of CTVs in planning CT images of breast cancer patients using a 3D convolutional neural network (CNN) compared to the manual process. MATERIALS/METHODS: An expert radiation oncologist (RO) segmented all CTVs separately according to international guidelines in 150 breast cancer patients. This data was used to create, train and validate a 3D CNN. The network's performance was additionally evaluated in a test set of 20 patients. Primary endpoints are quantitative and qualitative analysis of the segmentation data generated by the CNN for each level specifically as well as for the total PTV to be irradiated. The secondary endpoint is the evaluation of time efficiency. RESULTS: In the test set, segmentation performance was best for the contralateral breast and the breast CTV and worst for Rotter's space and the internal mammary nodal (IMN) level. Analysis of impact on PTV resulted in non-significant over-segmentation of the primary PTV and significant under-segmentation of the nodal PTV, resulting in slight variations of overlap with OARs. Guideline consistency improved from 77.14% to 90.71% in favor of CNN segmentation while saving on average 24 minutes per patient with a median time of 35 minutes for pure manual segmentation. CONCLUSION: 3D CNN based delineation for breast cancer radiotherapy is feasible and performant, as scored by quantitative and qualitative metrics.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Buelens P, Willems S, Vandewinckele L, et al. Clinical evaluation of a deep learning model for segmentation of target volumes in breast cancer radiotherapy. Radiother Oncol. 2022. PMID: 35447286. doi:10.1016/j.radonc.2022.04.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。