文献速递胸部肿瘤放疗放疗物理与技术

一种用于改善四维锥形束CT图像质量的循环生成对抗网络

A cycle generative adversarial network for improving the quality of four-dimensional cone-beam computed tomography images.
PubMed 文献 · Radiat Oncol · 2022-04-07

本研究利用循环生成对抗网络(CycleGAN)将20例肺癌患者的非配对胸部四维锥形束CT(4D-CBCT)与四维多层螺旋CT(4D-MSCT)图像进行训练,生成合成4D-CBCT(sCT)图像,并在另10例病例上测试。结果显示sCT图像伪影减少、肺部肿瘤区域清晰可见,CT值平均误差接近0 HU,结构相似性指数和峰值信噪比分别显著提高约51%和18%,gamma分析通过率超过90%,各器官剂量指数与4D-MSCT图像吻合良好(约5%以内)。作者结论认为CycleGAN提升了4D-CBCT图像质量,使其与4D-MSCT图像相当,基于sCT的自适应放疗用于肺癌临床实施是可行的。

要点

  • sCT图像伪影更少,肺部肿瘤区域清晰可见。
  • 所有器官区域CT值平均误差与平均绝对误差接近0 HU。
  • sCT图像SSIM和PSNR分别显著提高约51%和18%。

核心结论

  • 所提出的CycleGAN提升了4D-CBCT图像质量,使其与4D-MSCT图像相当。
  • 基于sCT的自适应放疗用于肺癌的临床实施是可行的。

研究设计与样本

  • 使用20例肺癌患者的非配对胸部4D-CBCT图像和4D-MSCT图像训练CycleGAN模型。
  • 在另10例病例上测试CycleGAN模型生成的高质量sCT肺部图像。

主要发现

  • 生成的sCT图像伪影更少,肺部肿瘤区域清晰可见。
  • 所有器官区域的CT值平均误差和平均绝对误差接近0 HU。
  • sCT图像的结构相似性指数和峰值信噪比分别显著提高约51%和18%。
  • gamma分析结果显著改善,使用sCT图像重算的剂量通过率超过90%。
  • sCT图像的各器官剂量指数与4D-MSCT图像吻合良好,差异在约5%以内。

关键数值与推荐

  • 采用48 Gy分4次容积旋转调强放疗计划,分别基于sCT图像重算并与4D-MSCT图像的理想剂量分布比较。
  • 以CT值平均误差和平均绝对误差评估CT值变化,以结构相似性指数和峰值信噪比比较sCT与原始4D-CBCT图像。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Four-dimensional cone-beam computed tomography (4D-CBCT) can visualize moving tumors, thus adaptive radiation therapy (ART) could be improved if 4D-CBCT were used. However, 4D-CBCT images suffer from severe imaging artifacts. The aim of this study is to investigate the use of synthetic 4D-CBCT (sCT) images created by a cycle generative adversarial network (CycleGAN) for ART for lung cancer. METHODS: Unpaired thoracic 4D-CBCT images and four-dimensional multislice computed tomography (4D-MSCT) images of 20 lung-cancer patients were used for training. High-quality sCT lung images generated by the CycleGAN model were tested on another 10 cases. The mean and mean absolute errors were calculated to assess changes in the computed tomography number. The structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) were used to compare the sCT and original 4D-CBCT images. Moreover, a volumetric modulation arc therapy plan with a dose of 48 Gy in four fractions was recalculated using the sCT images and compared with ideal dose distributions observed in 4D-MSCT images. RESULTS: The generated sCT images had fewer artifacts, and lung tumor regions were clearly observed in the sCT images. The mean and mean absolute errors were near 0 Hounsfield units in all organ regions. The SSIM and PSNR results were significantly improved in the sCT images by approximately 51% and 18%, respectively. Moreover, the results of gamma analysis were significantly improved; the pass rate reached over 90% in the doses recalculated using the sCT images. Moreover, each organ dose index of the sCT images agreed well with those of the 4D-MSCT images and were within approximately 5%. CONCLUSIONS: The proposed CycleGAN enhances the quality of 4D-CBCT images, making them comparable to 4D-MSCT images. Thus, clinical implementation of sCT-based ART for lung cancer is feasible.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Usui K, Ogawa K, Goto M, et al. A cycle generative adversarial network for improving the quality of four-dimensional cone-beam computed tomography images. Radiat Oncol. 2022. PMID: 35392947. doi:10.1186/s13014-022-02042-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。