文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

前列腺癌放疗期间精囊腺分次间和分次内运动:综述

Seminal vesicle inter- and intra-fraction motion during radiotherapy for prostate cancer: A review.
PubMed 文献 · Radiother Oncol · 2022-02-11

该综述检索了多个数据库共646篇文献,最终纳入22篇包含精囊腺运动三维信息的研究,报告了精囊腺分次间和分次内平移及旋转的平均值、系统误差和随机误差。精囊腺分次间和分次内运动显著,系统误差和随机误差分别为1-7 mm和1-5 mm,且与前列腺运动 largely 不相关;五项研究报告计划靶区 margin 约8 mm,与四项剂量学研究结果一致。

要点

  • 精囊腺分次间和分次内运动显著,系统误差1-7 mm、随机误差1-5 mm,与前列腺运动 largely 不相关。
  • 精囊腺平移在左右方向最小,而旋转在该轴最大;直肠和膀胱充盈状态是运动主因。
  • 五项研究报告计划靶区 margin 约8 mm,与四项剂量学研究一致;减轻运动(包括前列腺追踪)有潜力缩小 margin。

核心结论

  • 精囊腺分次间和分次内运动显著,系统误差和随机误差分别为1-7 mm和1-5 mm,且与前列腺运动 largely 不相关,减轻这些运动(包括前列腺追踪)有潜力缩小计划靶区 margin。

研究设计与样本

  • 综述检索了 Embase、Medline、Web of science Core collection、Cochrane CENTRAL register of trials 和 Google scholar,共找到646篇文献,最终纳入22篇包含精囊腺运动三维信息的研究。

主要发现

  • 精囊腺平移在左右方向最小,而旋转在该轴最大。
  • 直肠和膀胱充盈状态是精囊腺运动的主因,但使用不同膀胱和直肠准备方案时未观察到对运动幅度的明显影响。
  • 精囊腺与前列腺运动的最大相关性报告为 R2=0.7,而另外3项研究报告更低和/或不显著的相关性。
  • 五项研究报告计划靶区 margin 约8 mm,与四项相关剂量学研究结果一致。

关键数值与推荐

  • 精囊腺分次间和分次内运动的系统误差范围为1-7 mm,随机误差范围为1-5 mm。
  • 精囊腺与前列腺运动的最大相关性报告为 R2=0.7,另外3项研究报告更低和/或不显著的相关性。
  • 五项研究报告计划靶区 margin 约8 mm,与四项相关剂量学研究结果一致。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

A review of studies on seminal vesicle motion was performed to improve the understanding of these treatment uncertainties. This will aid planning target volume margin reduction, which is necessary for hypofractionation of high-risk prostate cancer. Embase, Medline, Web of science Core collection, Cochrane CENTRAL register of trials and Google scholar were searched for publications including 3D information on seminal vesicle motion. In total 646 publications were found of which 22 publications were eligible for inclusion. The mean, systematic and random error of inter- and intra-fraction translations are reported, as well as rotations. The translations of the seminal vesicles is smallest in the left-right direction, whereas the rotation was largest around this axis. Although rectal and bladder filling status were the main cause for seminal vesicle motion, no apparent effect on magnitude of motion was seen when different bladder and rectal preparation protocols were used. Inter- and intra-fraction motion of the seminal vesicles is significant. In the studies, systematic and random errors range between 1-7 mm and 1-5 mm respectively, and are largely uncorrelated to prostate motion. The maximum correlation between seminal vesicle and prostate motion was reported with an R2 of 0.7, while 3 other studies report lower and/or non-significant correlations. Five studies report a planning target volume margin of approximately 8 mm. This margin is in line with the results of four relevant dosimetric studies. Mitigating the inter- and intra-fraction motion of the seminal vesicles, including prostate tracking, has the potential to reduce planning target volume margins.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Brand VJ, Milder MTW, Christianen MEMC, et al. Seminal vesicle inter- and intra-fraction motion during radiotherapy for prostate cancer: A review. Radiother Oncol. 2022. PMID: 35157975. doi:10.1016/j.radonc.2022.02.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。