文献速递乳腺癌放疗放疗物理与技术

术前肺功能检查与体重指数在深吸气屏气放疗中:无辐射暴露早期预测心脏和肺部剂量

Preoperative spirometry and BMI in deep inspiration breath-hold radiotherapy: the early detection of cardiac and lung dose predictors without radiation exposure.
PubMed 文献 · Radiat Oncol · 2022-02-19

本研究纳入100例左侧乳腺癌保乳术后接受深吸气屏气放疗的患者,比较自由呼吸CT与深吸气屏气CT计划,分析术前肺功能检查与体重指数对平均心脏剂量和平均肺剂量的预测价值。结果显示用力肺活量(VC)与平均心脏剂量呈最强负相关(r=-0.33),体重指数(BMI)与平均肺剂量呈最强负相关(r=-0.34),两者在多变量分析中均显著(P<0.001)。VC模型与基于自由呼吸肺体积(LV-FB)的模型预测绝对残差无显著差异(中位绝对残差0.12 vs 0.11 Gy,P=0.79)。

要点

  • 术前VC与平均心脏剂量呈负相关(r=-0.33),BMI与平均肺剂量呈负相关(r=-0.34),多变量分析均显著(P<0.001)。
  • 老年和低VC是绝对残差增大的独立预测因素。
  • VC模型与LV-FB模型预测平均心脏剂量的中位绝对残差无显著差异(0.12 vs 0.11 Gy,P=0.79)。

核心结论

  • 术前肺功能检查和BMI分别是平均心脏剂量和平均肺剂量的显著预测因素。
  • 尽管老年和低VC患者可能有较大的预测变异,肺功能检查可能替代LV-FB作为平均心脏剂量的预测因素。

研究设计与样本

  • 纳入100例左侧乳腺癌保乳术后接受深吸气屏气放疗的患者,进行自由呼吸CT和深吸气屏气CT计划比较。
  • 完成相关性和多变量分析以建立剂量预测的线性回归模型,计算残差以探索不理想亚组并比较预测准确性。

主要发现

  • VC与平均心脏剂量呈最强负相关(r=-0.33),BMI与平均肺剂量呈最强负相关(r=-0.34),多变量分析均显著(P<0.001)。
  • 老年和低VC是绝对残差增大的独立预测因素。
  • VC模型与LV-FB模型预测平均心脏剂量的中位绝对残差无显著差异(0.12 vs 0.11 Gy,P=0.79)。
  • 平均肺剂量模型的中位绝对残差为0.38 Gy,未显示特定亚组有较大绝对残差。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to investigate preoperative spirometry and BMI as early predictors of the mean heart and lung dose (MHD, MLD) in deep inspiration breath-hold (DIBH) radiotherapy. METHODS: Left-sided breast cancer patients underwent breast-conserving surgery followed by DIBH radiotherapy enrolled. Patients who were not available for preoperative spirometry were excluded. One hundred eligible patients were performed free-breathing (FB-) CT and DIBH-CT for plan comparison. We completed the correlative and multivariate analysis to develop the linear regression models for dose prediction. The residuals were calculated to explore the unpreferable subgroups and compare the prediction accuracy. RESULTS: Among the parameters, vital capacity (VC) and BMI showed the strongest negative correlation with MHD (r = - 0.33) and MLD (r = - 0.34), respectively. They were also significant in multivariate analysis (P < 0.001). Elderly and less VC were independent predictors of increasing absolute residuals (AR). The VC model showed no significant difference in AR compared to the model using the CT parameter of lung volume in FB (LV-FB): median AR of the LV-FB model vs. the VC model was 0.12 vs. 0.11 Gy (P = 0.79). On the other hand, the median AR of the MLD model was 0.38 Gy, showing no specific subgroups of larger AR. CONCLUSION: Preoperative spirometry and BMI are significant predictors of MHD and MLD, respectively. Although elderly and low-VC patients may have larger predictive variations, spirometry might be a substitute for LV-FB as a predictor of MHD.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Koide Y, Shimizu H, Aoyama T, et al. Preoperative spirometry and BMI in deep inspiration breath-hold radiotherapy: the early detection of cardiac and lung dose predictors without radiation exposure. Radiat Oncol. 2022. PMID: 35183194. doi:10.1186/s13014-022-02002-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。