简化可自动分割功能性心脏图谱的开发
研究基于20例乳腺癌患者CT构建包含4个心腔、高风险心脏区(左前降支替代区)和2个心脏传导结节的简化心脏图谱,并在另20例CT上评估基于图谱的自动分割算法;4个心腔平均Dice系数0.78、高风险区0.65、窦房结0.56、房室结0.15,自动分割结构较手动勾画略小但剂量学参数相似。
要点
- 4个心腔平均Dice系数0.78,高风险心脏区0.65,窦房结0.56,房室结0.15。
- 自动分割结构较手动勾画略小,但剂量学参数相似。
- 图谱包含心脏传导系统,并以高风险心脏区替代左前降支以规避冠状动脉勾画困难。
核心结论
- 作者提出了一种包含心脏传导系统的简化功能性心脏图谱,并通过使用替代高风险心脏区规避了冠状动脉勾画困难。
- 大多数心脏亚结构具有可接受的基于图谱的自动分割性能。
- 该图谱可用于流行病学研究和临床实践。
研究设计与样本
- 基于20例乳腺癌患者CT扫描构建心脏亚结构图谱,包含4个心腔、作为左前降支替代区的高风险心脏区和2个心脏传导结节。
- 在另20例CT扫描组成的验证数据集上评估基于图谱的自动分割算法。
- 采用Dice相似系数评估手动与自动轮廓的一致性,并基于验证集患者调强放疗计划进行手动与自动分割亚结构的平均剂量和最大剂量剂量学比较。
主要发现
- 4个心腔平均Dice相似系数为0.78,高风险心脏区为0.65,窦房结为0.56,房室结为0.15。
- 与手动轮廓相比,自动分割亚结构略小,但剂量学参数相似。
临床怎么用
- 作者认为该图谱可用于流行病学研究和临床实践。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: There is increasing evidence that radiation doses to cardiac substructures are associated with cardiac adverse events. Manual delineation of cardiac substructures is time-consuming, and auto-segmentation of cardiac substructure atlases has consequently been evaluated. However, proper automatic delineation of small substructures, such as the left anterior descending coronary artery, is challenging, and auto-segmentation of cardiac conduction system substructures has never been evaluated, despite multiple reports of radiation-induced arrhythmia after thoracic irradiations. The aim of this study was to propose and evaluate a simplified auto-segmentable functional cardiac atlas. METHODS AND MATERIALS: We created a cardiac substructure atlas based on 20 computed tomography scans from patients with breast cancer comprising the 4 cardiac cavities, a high-risk cardiac zone as a left anterior descending coronary artery surrogate, and the 2 cardiac conduction nodes. Automatic delineation of this atlas by an atlas-based auto-segmentation algorithm was evaluated on a validation data set, consisting of 20 additional computed tomography scans. Dice similarity coefficients were used to evaluate the concordance level between the manual and the automatic contours; a dosimetric comparison between mean and maximum doses to the manual and to the auto-segmented substructures was additionally performed, based on intensity modulated radiation therapy treatment plans of the patients of the validation set. RESULTS: Average dice similarity coefficient values were 0.78 for the 4 cardiac cavities, 0.65 for the high-risk cardiac zones, 0.56 for the sinoatrial node, and 0.15 for the atrioventricular node. Compared with manual contours, auto-segmented substructures were slightly smaller but the dosimetric parameters were similar. CONCLUSIONS: We proposed a simplified functional cardiac atlas that included the cardiac conduction system and circumvented coronary delineation difficulties by using a surrogate high-risk cardiac zone. Most cardiac substructures were associated with acceptable atlas-based auto-segmentation properties. Such an atlas could be used for epidemiologic studies and for clinical practice.
引用
- Loap P, De Marzi L, Kirov K, et al. Development of Simplified Auto-Segmentable Functional Cardiac Atlas. Pract Radiat Oncol. 2022. PMID: 35192938. doi:10.1016/j.prro.2022.02.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。