前列腺与精囊体积变化及旋转对剂量的影响:MRI引导与CT引导立体定向体部放疗III期随机试验的事后分析
该III期随机试验事后分析纳入20例接受MRI引导前列腺SBRT(40 Gy/5次)的患者,前列腺与近端精囊PTV采用2 mm等距外扩。前列腺体积在放疗期间持续增大(第1-5次中位增幅0.1%、9.0%、12.1%、15.1%、14.2%,p=0.0016),前列腺旋转极小但近端精囊旋转明显。前列腺剂量学良好,近端精囊V95%≥95%仅在59%的分次中达到。
要点
- 前列腺体积在SBRT期间持续增大,第5次中位增幅14.2%(p=0.0016),新辅助ADT可显著减小基线体积(p=0.0042)。
- 前列腺分次间旋转极小,但近端精囊旋转明显(角α中位21.5°、角θ中位17.6°)。
- 前列腺CTV的V100%中位97.5%、近端精囊CTV为87.1%;V95%≥95%在前列腺94%分次达到、近端精囊仅59%。
核心结论
- 前列腺体积在SBRT期间持续增大,前列腺旋转极小但近端精囊旋转明显;前列腺剂量学良好,但可能需要在线自适应治疗以应对前列腺肿胀和近端精囊旋转。
研究设计与样本
- III期随机试验的事后分析,纳入MRI引导前列腺SBRT(40 Gy/5次)组的20例连续患者,前列腺与近端精囊PTV采用2 mm等距外扩。
- 在0.35 T模拟MRI及5次治疗前机载MRI上测量靶体积、前列腺尺寸及近端精囊轴向角α和矢状角θ,计算靶区Dice系数与靶区剂量学。
主要发现
- 所有患者前列腺体积在SBRT期间呈等距增大(p=0.0016),第1-5次中位增幅分别为0.1%、9.0%、12.1%、15.1%、14.2%,与基线体积无关;新辅助ADT显著减小基线体积(p=0.0042)。
- 前列腺分次间旋转极小,但近端精囊角α(中位21.5°)和角θ(中位17.6°)变化明显。
- 前列腺CTV的V100%中位97.5%,近端精囊CTV为87.1%;V95%≥95%在前列腺94%的分次中达到,在近端精囊为59%。
临床怎么用
- 作者认为,可能需要偶尔采用在线自适应治疗以应对前列腺肿胀,尤其是近端精囊旋转。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Interfraction volumetric changes/rotations in the prostate and proximal seminal vesicles (SVs) might compromise target coverage when tight margins are used for prostate stereotactic body radiotherapy (SBRT). We investigated on-board MRI images from MRI-guided SBRT to better understand this. MATERIALS AND METHODS: Twenty consecutive patients treated with MRI-guided prostate SBRT (40 Gy/5 fractions) enrolled on the MRI arm of a phase III randomized trial were included. A 2 mm isotropic margin was used for prostate and proximal SVPTV. Target volume, prostate dimensions, angles of the proximal SV on axial (angle α) and sagittal view (angle θ) were measured on a 0.35 T simulation MRI and five on-board pre-treatment MRIs. Dice coefficient of the targets and target dosimetry were calculated. RESULTS: All patients experienced an isotropic increase in prostate volume during SBRT (p = 0.0016): 0.1%, 9.0%, 12.1%, 15.1%, and 14.2% (median) at fractions 1-5, respectively, regardless of baseline volume, which was significantly reduced with neoadjuvant ADT (p = 0.0042). There was minimal interfraction rotation of prostate, however, considerable variations in proximal SV angle α (median 21.5°) and angle θ (median 17.6°) were seen. Median V100% was 97.5% and 87.1% for prostate and proximal SV CTV, respectively. V95%≥95% was achieved in 94% of fractions for the prostate and in 59% for proximal SV. CONCLUSION: Prostate volume consistently increased during SBRT. Interfraction prostatic rotation was minimal while rotation of the proximal SV was considerable. Prostate dosimetry was favorable, but online adaptive therapy may be indicated occasionally to account for prostatic swelling and in particular proximal SV rotations.
引用
- Ma TM, Neylon J, Casado M, et al. Dosimetric impact of interfraction prostate and seminal vesicle volume changes and rotation: A post-hoc analysis of a phase III randomized trial of MRI-guided versus CT-guided stereotactic body radiotherapy. Radiother Oncol. 2021. PMID: 34979212. doi:10.1016/j.radonc.2021.12.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。